FILTER HOUSING - PACK OF 2
MODEL NO: 9009
1. INTRODUCTION
Used to retain Sealey 9006 P2 R D particulate prefilter. Used in conjunction with Sealey 9001 and 9002
filter cartridges. Used in conjunction with filter cartridges gives greater adaptability. Supplied as a pair in a
resealable storage bag.
Type Examination Ref.: 0082/1694/079/03/22/0186
Notified Body: Apave Sudeurope sas (notified body number 0082)
2. SAFETY
IMPORTANT: The use limitations of these respirators depend on the type of lter they are used with as well as the conditions of the
environment user work in, contaminant concentration, type of work, etc. For an eective and proper use of the lters, read carefully the
following instructions and keep this document for further consultation.
8 These lters DO NOT supply oxygen (O
2
).
9 Use in adequately ventilated areas. DO NOT use in case of oxygen deciency.
8 DO NOT use in explosive atmospheres.
8 Filters should NOT be used in re-ghting or too work with open ames or molten metal since the combustion of the activated carbon
contained in the lters can generate high levels of toxic substances.
9 The right lter must be chosen according to concentration and type of contaminant in each case.
8 DO NOT use as protection against carbon monoxide under any circumstances.
8 DO NOT modify or repair the lter or cover. In case of damage or loss of seal, replace the product with a new one.
8 Filters, combined lters and absorbers require no maintenance or repair.
9 Leave work if respiratory protection is damaged, if you have diculty breathing and / or if you start to feel nauseous or dizzy.
8 DO NOT use respirators with lters or combined lters or absorbers in closed silos, wells, canals or other closed places without ventilation.
8 DO NOT use in an oxygen enriched atmosphere.
8 DO NOT use in an atmosphere with unknown air quality.
9 Use cleansers also as indicated in the respirator manual
8 DO NOT use if the storage took place under conditions other than those specied by the manufacturer. This may aect the shelf life.
8 DO NOT remove the adapter once installed during use.
9 Ensure the type of lter is the correct one for intended use, and that you have installed both lters of the same type.
9 Inspect the lters and respirator for any signs of damage before each use. If damaged or the item has expired it must be replaced.
9 Only use lters that have been stored correctly in their original packaging as per these instructions.
The use of lters must comply with current legislation, regulations about respiratory protection and regulations from various ocial bodies.
3. ASSEMBLY
3.1. BEFORE EACH USE
1. Read instruction for use carefully. 2. Make sure the type of lter is the correct one for intended use. 3. Make sure that you installed
both lters of the same type. 4. Make sure that the lter as well as the respirator do not present any signs of tearing, distortions, dents,
nor dirt Should this be the case, it must be disposed of. 5. Make sure lter is in its original packaging. 6. Filter must be inspected before
its use. In case of contamination, distortion and/or expiration it must be replaced.
3.2. FITTING THE FILTERS
Match the plastic lter connection with the lter holder on the mask. Press and turn the lter all the way clockwise. Repeat with second lter.
3.3. PRE-FILTER
An additional pre-lter can be tted if required. (Not supplied)
Assembly of 9006 (pre-lter) and 9009 (cover). Place the 9006 pre-lter onto the 9001 lter with the printed side facing in. Place the 9009
cover on the lter and press together. Verify that the pre-lter covers the 9001 lter. Reverse the procedure to disassemble the product.
9009 Issue 1 01/05/24
Original Language Version
© Jack Sealey Limited
REFER TO INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.

4. OBSOLESCENCE
Filters, combined lters, absorbers and cover have the production date on the packaging and on the product. The use-by date
is 5 years from the production date, which is valid when stored in the original packaging in accordance with the manufacturer’s
recommendations.
5. FILTER DISPOSAL
Once lters have been used, they must be disposed of according to the current national legislation.
EU | Sealey EU Ltd, Farney Street, Carrickmacross, Co. Monaghan, A81 PK68 Ireland
UK | Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
REGISTER YOUR
PURCHASE HERE
This document has been drawn up according to Regulation (EU) 2016/425 as amended to apply to GB for Personal Protective
Equipment. The declaration of conformity can be accessed at www.sealey.co.uk.
9009 Issue 1 01/05/24
Original Language Version
© Jack Sealey Limited