AI-FIRE
AI-FIRE
Required configuration
AI-FIRE must be configured according to the following guidelines:
1. Draw a sensor and configure a latency time of at least 5 seconds.
2. If you want to avoid multiple alarms for the same smoke, increase the inhibition time.
3. Enable the flag “Verify fire”.
4. Configure the verification sensitivity (recommended value 0.85).
5. Configure the parameters for background updating, for the application of the morphological operators,
and the fire detection threshold (recommended value 40) to detect moving objects like flames.
6. Configure the minimum and the maximum size in pixels of a flame.
7. if you are framing a scene with an extended depth of field, calibrate the camera and the algorithm and
configure the minimum and maximum real size of a flame.
8. Configure at least one event manager to collect the events.
9. If needed, schedule the applications in specific time intervals.