2N 91378375 Indoor Touch 2.0 Answering Unit

2N Indoor Touch 2.0 Installation User Manual - Page 67

For 91378375.

PDF File Manual, 135 pages, Read Online | Download pdf file

91378375 photo
Loading ...
Loading ...
Loading ...
2N TELEKOMUNIKACE a.s., www.2n.cz67/135
3.3.3.6 Input and Output
This section helps you set the input/output parameters.
DOOR BUTTON
– enable/disable the function.
Door button
ON by default. Define the pulse rise/fall time detection
Inverted input mode
and application response. With ON, the application does not start ringing until
the fall time is detected whenever the button is released. With OFF, the ringing
starts when the rise time is detected the moment the button is pressed.
– display the input to which the door button is connected.Used input
– set the lower ringing limit after the button is pressed.
Minimum ringing time
– set the upper ringing limit after the button is pressed.
Maximum ringing time
– select the default user ringing.Door ringtone
make the application ring via DND if ON is set.
Bypass DNDmode