Forte FDR366BSS 36 Inch Freestanding Dual Fuel Range

USER MANUAL & INSTALLATION GUIDE - Page 28

For FDR366BSS. Also, The document are for others Forte models: FDR304B, FDR366B, FDR488B

PDF File Manual, 32 pages, Read Online | Download pdf file

FDR366BSS photo
Loading ...
Loading ...
Loading ...
Instructions forConverting Range to Operate on Liqueed Petroleum Gas
|
INSTALLATION AND SERVICES MUST BE PERFORMED BY A QUALIFIED INSTALLER
IMPORTANT: SAVE INSTRUCTION MANUAL FOR THE LOCAL INSPECTOR'S USE.
READ AND SAVE THESE
INSTRUCTIONS FOR FUTURE REFERENCE
,一
This conversion kit must be installed by a qualified service
technician in accordance with the manucturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. Failure to follow
instructions may result in fire, explosion or production of carbon monoxide causing
property damage, personal injury or loss of life. The qualified service agency is
responsible for the proper installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is checked as specified in
the manucturer's instructions supplied with this kit.
,一
Before proceeding with the conversion, shut off the gas supply
before disconnecting electrical power to the range. Be sure power supplies are off
before installing the conversion kit. Failure to do so could cause serious bodily injury.
Determine the combination of top burners that are featured on your range. Identi
the parts you need from this kit to complete the L conversion. When burners are
converted from natural to L the BTU ratinas are as follows:
[ 0.74mm]
[ 0.90mm]
[ 1.0mm]
[ 1.16mm]
[0.89*2+0.53mm]
Top Burner
Top Burner
Top Burner
Top Burner
Top Burner
6,000 BTU L Gas
9,000 U L Gas
12,000 BTU L Gas
15,000 BTU L Gas
20,000 BTU L Gas
*Note: For operation at elevations above 2000., appliance rating shall be reduced at the rate of 4%
r each 1000 . above sea level
IMPORTANT: After replacing the natural gas to LP orifices, be sure to keep the original
factory installed natural gas orifices for future range conversion back to natural gas.
The original orifices are Nature Gas:
Tools Reguired for L Conversion:
[ 1.07mm]
2mm Allen Wrench
Top Burner 6,000 BTU
Top Burner 9,000 BTU
Top Burner 12,000 BTU
Top Burner 15,000 BTU
Top Burner 20,000 BTU
�-��
mm
3/8 & 1/2 & 5/8" [19mm] Open End Wrench
[
L
?mm]
1/8" Wide Flat Blade Screwdriver
[ 1.79mm]
Phi|ips Screwdriver
[ 1.36*2+0.73mm ]
7mm Nut Driver
1/4 Nut Driver
Adjustable wrench.
28
18Broil 240v,60hz,2000w
18Oven 240v,60hz,1600w
30Broil 240v,60hz,3200w
30Oven 240v,60hz,2800w
36Broil 240v,60hz,3200w
36Oven 240v,60hz,2800w
18Broil 240v,60hz,2000w
18Oven 240v,60hz,1600w
30Broil 240v,60hz,3200w
30Oven 240v,60hz,2800w
36Broil 240v,60hz,3200w
36Oven 240v,60hz,2800w
Loading ...
Loading ...
Loading ...