This is the main product document for model PAWM1.

The file format is pdf, 11 pages, you can download this manual here .

background
WARM MIST TABLETOP
HUMIDIFIER
FOR MODEL:
PAWM1
Before using your ultrasonic humidifer,
please read this manual carefully and keep
it for future reference, along with your receipt.
USER MANUAL
background
Safety Guidelines......................................................................2
Structure Diagram ....................................................................3
Technical Data ...........................................................................3
Operating Instructions
• Setting Up Your Humidier............................................4
• Filling/Relling Your Humidier....................................4
• How to use Your Humidier ..........................................5
• Using Liquid Inhalant........................................................5
• Night Light ...........................................................................6
Weekly Cleaning & Care ....................................................6–7
Storage Instructions................................................................8
Warranty.......................................................................................8
Troubleshooting........................................................................9
1
CONTENTS
background
SAFETY GUIDELINES
To reduce the risk of electrical shock, this product has a polarized plug (one blade is wider than
the other). As a safety feature this plug will fit into the outlet only one way. If the plug does not fit
fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT
attempt to bypass this safety feature. Improper use of electric cords and plugs can cause a fire or
electric shock hazard. NEVER pull on the cord to remove the plug from the outlet. Grip plug and
pull from outlet. Check the power cord and plug for damage. A damaged cord or plug must be
repaired before using the humidifier.
DANGER!
When using electrical appliances, basic safety precautions should always be followed. Doing so
will reduce the risk of fire, electrical shock, and injury to persons. Please adhere to the following
safety instructions:
1. The unit should always be placed on a firm, flat, waterproof surface at least 4 ft away from
the bedside, 12 in. from the wall and out of reach of patients, children and pets.
2. The unit should not be left unattended in a closed room as air can become saturated and
result in condensation on walls and furniture. Always leave room door at least partially open.
3. Before using the unit, extend the cord and inspect it for any signs of damage. DO NOT use
the unit if the cord has been damaged.
4. To avoid fire or shock hazard, plug the appliance directly into a 110-120V AC electrical outlet.
5. The unit should always be unplugged and emptied when not in operation or while being
cleaned. Shut off and unplug the appliance before moving it. DO NOT move or tilt unit while
it is in operation. Plug and unplug humidifier with dry hands. NEVER pull by cord.
6. DO NOT operate the unit without water in the tank. Turn off and unplug the unit when the
tank is empty and the refill light is on.
7. CAUTION: DO NOT use an extension cord. Doing so can result in fire, shock, or
personal injury.
8. Unit requires regular cleaning. See cleaning instructions in this manual.
9. DO NOT operate the unit outdoors. It is intended for indoor use only.
10. DO NOT cover or insert objects into any openings on the unit.
11. DO NOT attempt to repair or adjust any electrical or mechanical functions on the unit as
doing so will void your warranty and may result in injury.
12. DO NOT add any medications into the chimney, base, reservoir or water tank (only in the
medicine cup.)
13. DO NOT touch the steam vapor. Steam can cause burns. Do not operate without the
medicine cup in place on top of the mist chimney.
14. When moving or lifting the tank, use one hand on the tank handle and the other on the
bottom of the tank.
15. The unit is for residential use only.
2
background
FOR HOUSEHOLD USE ONLY
3
All data was tested by the factory and is for
reference only.
This product is designed for home use only.
Power Switch
Heating Element
TECHNICAL DATA
Model No.: PAWM1
Water Tank: 1.0 gal
Run Time*: 12 24 hrs
*based on output setting
Output per Day: 1.9 gal/day max.
Output per Hour: 10.1 oz/hr max.
Electrical Rating: 110-120V, 60 Hz
Power: 260W
STRUCTURE DIAGRAM
Pictures for reference only.
Your warm mist humidifier is designed to provide visible, warm moisture. The humidifier tank
delivers water into the boiling chamber where it is heated until it produces a steam vapor. The
steam vapor mixes with dry air in the mist chimney and is released into the room.
background
4
OPERATING INSTRUCTIONS
SETTING UP YOUR HUMIDIFIER
1. Remove from box. Remove packaging material. Set aside
instruction manual. Recycle packaging materials or save for
storage.
2. Remove twist tie from power cord and extend power cord full
length. DO NOT OPERATE WITH POWER CORD COILED
OR TWIST TIE IN PLACE.
3. Ensure proper assembly. Make sure mist chimney and water
tray are securely in place. (Fig. 1)
4. Additionally, make sure blue latch is engaged. (Fig. 2)
5. Select a firm, level location at least 12 in. from any walls.
Place the humidifier on a water-resistant surface. Steam
should be directed away from any walls, bedding or furniture.
Perfect Aire will not accept responsibility for property
damage caused by water spillage.
WARNING: KEEP OUT OF REACH OF CHILDREN.
This product produces HOT STEAM and should be placed in an area not accessible to
children or pets, ensuring that the power cord is securely out of reach.
FILLING/REFILLING YOUR HUMIDIFIER
NOTE: When moving or lifting the tank, use one hand on the
tank handle and the other on the bottom of the tank.
1. Remove tank by grasping handle and gently pulling up.
Remove tank cap located on bottom of tank by turning the cap
counter-clockwise.
2. Fill the tank with water (never warm/hot water).
NOTE: Distilled water is recommended (but not required) to
reduce mineral deposits.
3. Replace the tank cap by turning it clockwise to screw it back in place on the tank. See Fig. 3.
Take care not to over-tighten. Place the tank back onto the humidifier base.
RESET:
1. When your humidifier is out of water the refill light will
illuminate. See Fig. 4.
2. Turn the humidifier off, wait 20–30 minutes, refill the tank, and
turn the humidifier back on.
Fig. 3
Fig. 4
Fig. 1
Fig. 2
C
l
o
c
k
w
i
s
e
t
o
T
i
g
h
t
e
n
background
HOW TO USE YOUR HUMIDIFIER
1. Power: With the power switch in the OFF position (), plug the filled humidifier into a
polarized 110-120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; It
will only fit one way. DO NOT plug in humidifier with wet hands to avoid electric shock.
2. Output: Set output control to high ( ) or low ( ).
Indications your humidifier is operating are that the green nightlight on the control knob will
illuminate and, after 1-2 minutes, your humidifier will produce a visible steam.
3. Humidity Level: Once you have reached a comfortable humidity level your humidifier should
be turned to the low setting. A comfortable humidity level is between 40–50%.To monitor your
humidity level it is recommended you use a hygrometer. If you notice condensation on the
walls or windows you should turn your humidifier off as your humidity level is too high.
4. CAUTION:
DO NOT remove the mist chimney, removable tray, water tank or medicine cup when
humidifier is in use or for at least 2030 minutes after unit has been turned off and unplugged.
When moving the humidifier, turn it off, unplug it, and wait 20–30 minutes before moving it.
Never operate the humidifier without the tank in place.
Never attempt to operate the unit if the humidifier tank is empty.
Do not attempt to operate your humidifier without the mist chimney, removable tray, and
medicine cup properly assembled and securely in their correct places.
USING LIQUID INHALANT
Liquid inhalants such as Vicks VapoSteam
®
or Kaz Inhalant* can be used in the medicine cup.
ONLY USE LIQUIDS THAT ARE RECOMMENDED FOR THIS TYPE OF HUMIDIFIER.
1. Add 1 Tablespoon inhalant to the medicine cup.
2. NOTE: Some residue from inhalant may be left in the medicine cup after use. With the
humidifier turned off, unplugged and cooled for at least 20 minutes, gently wipe residue from
medicine cup.
3. DO NOT ADD LIQUID INHALANTS OR ANY ADDITIVES TO THE WATER. DOING SO CAN
HAVE ADVERSE EFFECTS ON THE HUMIDIFIER.
*Vicks VapoSteam® and Kaz Inhalant are not manufactured or distributed by Perfect Aire, LLC,
distributor of the Perfect Aire Warm Mist Humidifier (PAWM1).
OPERATING INSTRUCTIONS
5
Continued
background
6
Continued
HOW TO USE THE NIGHT LIGHT
Press the button on the left side of unit by hand to illuminate the blue light on the tank bottom.
Press the button again to turn off the night light.
NOTE: All maintenance should be done in the kitchen or bathroom on a water resistant surface.
To properly clean your humidifier we recommend the process of scale removal and
disinfecting shown in this manual.
DISHWASHER SAFE: The following parts are TOP RACK dishwasher safe for residential
dishwashers operating at temperatures below 158°F (70°C). See Fig. 5 below.
Run the dishwasher on the light duty or normal cycle.
Do not wash with soiled articles/dishes. DO NOT USE DETERGENTS. If you use your
dishwasher you will not need to follow the disinfecting and scaling procedures described on the
following pages.
Please Note: Do not place parts on lower rack of dishwasher. Doing so could cause
damage to the humidifier parts and dishwasher.
OPERATING INSTRUCTIONS
WEEKLY CLEANING & CARE
THE MAIN HOUSING (Fig. 6a) AND WATER TANK
(Fig. 6b) ARE NOT DISHWASHER SAFE.
Placing these parts in the dishwasher will
damage your humidifier and render it unable to
operate properly.
Fig. 5
Fig. 6a Fig. 6b
Medicine Cup Removable Tray Mist Chimney
background
7
How to Remove Scaling
1. CAUTION: Always turn off the power switch and disconnect the power cord from the electrical
outlet before cleaning. If the humidifier has recently been in use, wait 20–30 minutes for unit to
cool before beginning cleaning process.
2. Remove water tank and empty it.
3. Disassemble the mist chimney by gently pushing on the blue release latch
and pulling upwards. (See Fig. 7.)
4 Remove the removable tray by pushing on the blue removable tray lift tab
and gently pulling tab upwards. (See Fig. 8.)
5. Pour 1 cup of vinegar into tank and fill the remainder of the tank with water.
6. Wipe mist chimney, medicine cup and removable tray with the
solution from the tank.
7. Put cap back onto tank and return tank to base, soaking the
heating element for 15–20 minutes. Then, gently scrub heating
element with a soft brush to remove any mineral deposits. DO NOT
use hard brushes, steel wool or other harsh abrasives on the
heating element. Doing so will damage the heating element.
Rinse tank, base, mist chimney, removable tray and medicine cup
until smell of the solution is gone.
CAUTION: DO NOT IMMERSE BASE IN WATER.
8. Next, disinfect the unit by following the instructions below.
How to Disinfect Following Removal of Scaling
1. Pour 1 teaspoon of bleach into the tank.
2. Fill the remainder of the tank with water.
3. Follow steps 6 and 7 of “How to Remove Scaling”
section (above).
Note: Please be careful of clothing, rugs, and other
non bleach-resistant materials when disinfecting.
Spilling bleach on clothing, rugs, and certain
surfaces may cause damage.
NOTE: USING MORE THAN 1 TEASPOON OF BLEACH PER GALLON (3.8L) OF WATER
WILL RESULT IN DAMAGE TO YOUR HUMIDIFIER.
Re-Assembling
1. Push blue tab to the open position. Place water tray and then mist chimney back on the
humidifier. Make sure they are sitting securely and the blue latch is in the closed position.
2. Snap medicine cup back in place if removed.
3. Put tank cap back on water tank and place water tank back on unit.
WEEKLY CLEANING & CARE
Continued
Fig. 9a Fig. 9b
Fig. 7
Fig. 8
background
8
When the humidifier will not be used for at least one week, follow the Cleaning Instructions on
pages 6 and 7 of this manual.
At the end of the season, remove any accessories from the humidifier.
Dry the humidifier completely before storing. DO NOT store with water inside the main housing
reservoir or water tank.
Pack unit in original carton and store in a cool, dry location.
END OF SEASON CARE & STORAGE
background
9
Please check the following troubleshooting tips before calling for assistance.
TROUBLESHOOTING
NOTE: Failure to keep this unit clean from mineral deposits normally contained in any water
supply will affect the efficiency of operation of this unit. Customer failure to follow these
instructions may void the warranty.
PROBLEM POSSIBLE CAUSESOLUTION
Power switch is set to
“On” and nighlight is off.
Unit not plugged in.Plug unit in.
No power at outlet.
Check circuits, fuses,
test outlet.
Little or no mist is
produced.
No water in tank. Fill water tank.
Unit is not level.Place on a level surface.
Mineral deposits on hearing
element or removable tray.
Follow cleaning instructions on
pages 6–8 of this manual.
Water tank was washed with
detergent.
Rinse thorougly with
clean water.
Reset light is illuminated.
Water tank is empty. Re ll water tank.
Unit not reset after refi ll.
Follow reset procedure on
page 4.
Water over ows from
reservoir.
Tank may be leaking.
Check the tank for leaks and
replace if necessary.
Tank cap is not tight.
Tighten tank cap.
(Do not overtighten.)
Condensation forms
around humidifi er or
windows.
Mist intensity is set too high
for room size or pre-existing
humidity level.
Decrease mist output to
low setting or open door to
the room.
Night light is not
illuminating.
LED light damage.
Consult a qualifi ed professional
to change the LED light.
Night light button may be
malfunctioning.
Consult a qualifi ed professional
to repair/replace the night light
control button.
LED night light will not
turn off.
Night light button may be
malfunctioning.
Consult a qualifi ed professional
to repair/replace the night light
control button.
background
Perfect Aire, LLC
5401 Dansher Rd.
Countryside, IL 60525
Distributed by:
844-4PA-AIRE | 844-472-2473
www.perfectaire.us
Specification and performance data is subject to change without notice.
Printed in China