7.39 camera PTZ control (IZ series)
Group: camctrl_c<0~(n-1)> for n channel products
(capability_camctrl_c0_zoommodule = 1 and
capability_camctrl_c0_buildinpt = 0)
n denotes the value of "capability_nvideoin" and k denotes the value of "capability_npreset"
NAME VALUE SECURITY
(get/set)
DESCRIPTION
ccdtype string[16] 6/7 (Internal used, read only)
motortype string[16] 6/7 (Internal used, read only)
cameraid 0 ~ 255 1/4 Camera ID controlling external PTZ
camera.
Note:
Please set your speed dome to the
appropriate baud rate, and Camera ID,
e.g. 2400bps, camera ID 1,2,3,,,,etc.
All Camera IDs on the same controlling
system (NVR or rs485 keyboard) have
to be distinct.
Therefore, once you send a controlling
signal, each camera will only accept the
inputs with the corresponding ID.
panspeed -5 ~ 5 1/4 Pan speed
tiltspeed -5 ~ 5 1/4 Tilt speed
zoomspeed -5 ~ 5 1/4 Zoom speed
autospeed -5 ~ 5 1/4 Auto pan speed
focusspeed -5 ~ 5 1/4 Auto focus speed
focusmode auto,onetimeauto,spotligh
t,manual
* Available values are
listed in
"capability_camctrl_c<0~
(n-1)>_focusmode"
1/4 Indicate the focus control mode.
uart 0 ~ "capability_nuart"-1 1/4 Select corresponding uart
(capability.nuart>0).
isptz 0 ~ 2 1/4 0: disable PTZ commands.
1: enable PTZ commands with PTZ
driver.
2: enable PTZ commands with UART
tunnel.