20. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the
air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HC0038
1
2
3
HC0056
0
1
2
1
2
4
3
AB
1) HALOGEN LIGHT KNOB
2) BLOWER SPEED CONTROL KNOB
3) ON/OFF BLOWER SWITCH
1) HALOGEN LIGHT KNOB
2) BLOWER SPEED CONTROL KNOB
COOKTOP LIGHTING (HALOGEN)
A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity).
BLOWER
The blower is operated using two controls.
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower operates at the speed set by the speed control
button (2).
Turn the speed control knob clockwise to increase blower speed – counterclockwise to decrease speed.
HEAT SENTRY™
This hood is equipped with a Heat Sentry™ thermostat. This thermostat is a device that will turn on or speed up the blower if it senses
excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to the last selected speed.
2) If blower is already ON speed will remain the same.
When the temperature level drops to normal, the blower will
return to its original setting.
WARNING
!
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the power
pack is turned off. In this case, it is impossible to turn the blower OFF using control panel buttons.To stop blower
and lighting: Set the main power switch (located behind the baffle filters) in OFF position (if it is possible to do so
safely). See illustration below.