11
9 Once the connection is done, in necessary to adjust the
9-6 wire connector with the included strap.
A
B
C
D
A. Ground wires
connection
B. 6-9 wire connector
C. Strap
D. Strain relief
10 Reinstall the external blower terminal box cover and
screws.
11 Reinstall the front cover of the external blower housing
and secure it with 20 mounting screws and 20 neoprene
washers.
Electrical Connection Inside Range Hood
Between External Blower System
and Range Hood
1 With the range hood mounted (see the range hood
installation instructions), locate the wiring cable connector
inside the range hood.
A
B
C
D
A. Range Hood Junction Box
B. Range Hood knockout for Wire
Connector Assembly
C. Wire Connector Assembly (provided
in the External Blower Kit)
D. Power Supply Wiring Conduit
2 Connect the 6 wire connector assembly supplied with
the external blower motor system to the mating connector
from the range hood.
A. Wire Connector Assembly (provided in
the External Blower Kit)
B. Hood Insert Blower Connector
A B
3 Install UL listed or CSA approved strain reliefs. Run
through the strain reliefs the 6 wire connector
and the external Blower wiring conduit (not incluided
leaving enough wire length to make the wiring
connections.
4 Tighten the strain relief screws.
5 Connect the wires from the 6- wire connector assembly
to the wires from the wiring conduit inside the range hood
terminal box.
NOTE: Connect the green (or green/yellow) ground
wire from the wiring conduit to the green (or bare)
ground wire from the home power supply and to the
and to the green/yellow ground wire from the 6-wire
connector assembly (H) using UL listed wire connectors
(see the “Make Electrical Power Supply Connections
to Range Hood” section in the range hood installation
instructions).
A
B
C
D
E
F
G
H
I
A. Strain relief
B. UL listed wire
connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/
green) and green /
yellow wires
I. Motor electrical plug
cable
6 Connect the home power supply wiring to the range
hood following the instructions that are supplied with the
range hood.
7 Reinstall the range hood terminal box cover.
8 Reconnect power.
NOTE: For the Range Hood Models EVV636S1, EVV648S1,
EVI642S1, EVI648S1 follow the next instructions.
NOTE: For the Range Hood Models EVV636S1, EVV648S1,
EVI642S1, EVI648S1 use de 9 wire connector assembly and
the 15.9mm strain relief.
1 With the range hood mounted (see the range hood
installation instructions), locate the wiring cable connector
inside the range hood.
2 Disconnect the Hood Insert Blower Connector.
A. Hood Insert
Blower Connector
B. Hood Smart
B
A
Loading ...