Follett 15CI100AIWCFST00 15CI100A-IW-CF-ST-00 15 15 Series Ice & Water Dispenser Chewblet Style Ice, 125 lb

User Manual - Page 14

For 15CI100AIWCFST00.

PDF File Manual, 48 pages, Read Online | Download pdf file

15CI100AIWCFST00 photo
Loading ...
Loading ...
Loading ...
14 7CI100A/7FS100A, 15CI100A/15FS100A
Cleaning and Sanitizing Procedure
Cleaning and sanitizing should be performed at least every 6 months (more often
if local water conditions dictate).
WARNING!
§ Place the dispenser in Maintenance Mode prior to servicing or
cleaning the ice machine. See
Maintenance/Cleaning Mode on
page 12.
§ For protection, rubber gloves and safety goggles (and/or face shield)
should be worn when handling SafeCLEAN Plus™.
§ Do not use bleach, it will damage the dispenser.
Required Supplies
§ 7 Series
: Follow the directions on the SafeCLEAN Plus packaging to mix
3 gal (11.4 L) of Follett SafeCLEAN Plus solution. Use 100 F (38 C) water.
15 Series
: Follow the directions on the SafeCLEAN Plus packaging to mix
6 gal (22.7 L) of Follett SafeCLEAN Plus solution. Use 100 F (38 C) water.
§ Funnel, bucket,
100 F (38 C
) potable water
Ice machine and Dispenser
1. Dispense all the ice out of the unit.
2. Press and hold maintenance/clean switch until displays in the user
interface to enter Maintenance Mode.
3. Remove (unscrew) chrome ice dispense chute (Fig. 14.1).
4. Remove drip tray (Fig. 14.2).
5. Remove (2) screws located behind the drip tray (Fig. 14.3).
6. Move front panel and place on top or beside unit (Fig. 14.4).
7. Remove plug cap from the end of drain tube (Fig. 14.5) and lower tube
to drain water into bucket. After the system has been drained of water
replace plug cap in drain tube.
8. Secure tube in holder.
9. Remove cap from bin lid cover (Fig. 14.6).
10. Screw bin lid cover cap onto ice discharge chute (Fig. 14.7).
Fig. 14
1
2
3
4
6
5
7
11. Pour SafeCLEAN Plus solution into bin lid access spout until solution reaches the spout neck.
12. Allow the SafeCLEAN Plus solution to remain in unit for 15 minutes.
13. While machine is cleaning, remove top and right side panel to access and clean air-cooled condenser.
14. Submerge ice dispense chute in the remainder of SafeCLEAN Plus solution for 2 minutes. Rinse with
clean, potable water.
15. Drain system by lowering drain tube into bucket.
16. Secure drain tube into holder.
1 7. Fill and drain twice with potable water. Secure drain tube.
18. Place a bucket under the dispense chute and remove cap. Note: Some SafeCLEAN Plus solution will
remain and drain out when cap is removed. Reposition cap on bin lid spout.
19. Reinstall front panel, ice dispense chute, and drip tray.
20. Press and hold maintenance/clean switch to exit Maintenance Mode.
Loading ...
Loading ...
Loading ...