Hantek HDP135V6S power supply with RS232

HDP135V6 DC Power Supply Manual

For HDP135V6S.

PDF File Manual, 3 pages, Read Online | Download pdf file

HDP135V6S photo
HDP135V6 DC Power Supply User Manual
I. Product Introduction
HDP135V6 power supply is a high quality,
cost-effectiveDC power supply. It has four-digit LED
voltage and current display. It also has over voltage
protection (OVP), over current protection (OCP), over
temperature protection (OTP) and USB quick charging
functions.
II. Product Model
Model CH Output V/A
LCD
digits
RS232 AC input
HDP135V6
1
35.2V/6.2A
4
None
115/230VAC
HDP135V6A
1
35.2V/6.2A
4
None
230VAC
HDP135V6B
1
35.2V/6.2A
4
None
115VAC
HDP135V6S
1
35.2V/6.2A
4
Yes
115/230VAC
III. PerformanceSpecifications
1 Rated Working Condition
AC input: 115 VAC ± 10%, 230 VAC ± 10%, 50/60Hz
Working Conditions: Temperature -10~40
Relative humidity ≤80%
Storage Conditions: Temperature -20~60
Relative humidity ≤80%
2 Specifications
All technical specifications can only be guaranteed
when the instrument is operated continuously for more
than 30 minutes at the specified operating temperature
(18 to 28).
Voltage
Load Regulation
Line Regulation
Set Resolution
Set Accuracy
Readback
Resolution
10mV
Readback Accuracy
Ripple
Current
Load Regulation
Line Regulation
Set Resolution
Set Accuracy
Readback
Resolution
1mA
Readback Accuracy
Ripple
OVP
Maximum Voltage
OCP
Maximum Current
Quick Charge
Output Voltage
Range
5V ~ 12V
Output Power
Maximum: 18W
Supported Quick
Charging Protocol
DCP (Apple, Samsung and BC1.2),
Qualcomm QC2.0/QC3.0, Huawei
Quick Charge Protocol FCP, Samsung
Quick Charge Protocol AFC
General Features
Remote Interface
RS232 (Optional)
Baud rate: 2400
Data bit: 8
Stop bit: 1
No parity check
AC Input
115 VAC ± 10%,
230 VAC ± 10%,
50/60Hz
Working Conditions
Temperature -10 to 40
Relative Humidity ≤ 80%
Storage Conditions
Temperature -20 to 60
Relative Humidity ≤ 80%
Cooling
Air cooling
Weight
2.2 Kg
Size
85 * 150 * 230 (mm)
IV.Front Panel
1 Voltage Display
2 Current Display
3 Save and Recall Keys M1 ~ M10
M1 ~ M4: Press [M*] once, and the indicator lights
up to display the group settings.Use the voltage and
current adjustment knobs to adjust the settings that
need to be saved, and then long press the [M*]key
until the indicator lights up, the settings will be saved
in the [M*] position.
M5 ~ M10: To use M5 ~ M10 to save and recall, use
it in conjunction with the [Shift] key.TakingM5 as an
example, press the [Shift]key and the [Shift]
1
Loading ...
Loading ...

Other documents for Hantek HDP135V6S

The following documents are available:
User Manual Photos

Specifications