Event Tables Format
Each bus type (UART, I
2
C, SPI, CAN, LIN) can have an event table
saved containing each bus event as a .CSV file. For serial buses, an
event is defined as the data on the bus when a Stop or End of
Packet (UART) is encountered. The data associated with each event
and the time of each event is recorded.
File Type
Each event table is saved as
Event_TableXXXX.CSV into the designated file
path. Each event table is numbered sequentially
from 0000 to 9999. For example the first event table
will be saved as Event_Table0000.CSV, the second
as Event_Table0001.CSV, and so on.
Event Table Data
Each event table saves a timestamp of each event
relative to the trigger as well as the data in each
frame/packet at the time of an event. The
frame/packet data is saved in HEX format.
The table below lists in order the data saved for
each event table.
UART
Time, Tx frame data, Rx frame data,
Errors.
I
2
C
Time, Repeat Start, Address, Data,
Missing Ack.
SPI
Time, MISO frame data, MOSI
frame data.
CAN
Time, Identifier, DLC, Data, CRC,
Missing Ack.
LIN
Time, Identifier, Parity, Data,
Checksum, Errors.