Hikvision DS-KAD706Y-S Two Wire Distributor

Quick Start Guide

For DS-KAD706Y-S.

PDF File Manual, 1 pages, Read Online | Download pdf file

DS-KAD706Y-S photo
DS-KAD706Y-S(P)
1
3
2
1 2 3
4 5
1
4 5
6
3
2
6
4
Two-Wire Video & Audio Distributor
4
1
2
3
1
2
NetworkNetwork
DS-KAD706Y-S DS-KAD706Y
Door Station
UD29994B
Model Manufacturer
KPL-060M-II Channel Well Technology Co., Ltd
The detail for the power adapter contained in the DS-
KAD706Y-SP package is as follows:
MAX
6W
24VDC
24 VDC
Power Input
24 VDC
Power Input
24AWG(0.2 mm², 9
Ω/100 m)
20AWG(0.5 mm², 3.5
Ω/100 m)
18AWG(0.8 mm², 2.5
Ω/100 m)
All
DS-KAD706Y - DS-KAD706Y-S Transmission
Distance 60 m
Transmission
Distance 60 m
Transmission
Distance 60 m
DS-KAD706Y - DS-KAD706Y Transmission
Distance 60 m
Transmission
Distance 60 m
Transmission
Distance 60 m
DS-KAD706Y-DS- KD8003Y-IME2 Transmission
Distance 35 m
Transmission
Distance 35 m
Transmission
Distance 35 m
Transmission
Distance 35 m
Transmission
Distance 35 m
Transmission
Distance 60 m
Transmission
Distance 60 m
DS-KAD706Y-DS-KH6320Y-WTE2 Transmission
Distance 35 m
Transmission
Distance 60 m
Transmission
Distance 60 m
Twisted Pair Parallel lines
Routing Path
Diagram References
Appearance
Power Indicator
Network Interface Network Indicator
Terminals Reset Button
Power Input
Wiring
Wire the devices with power supply cables as picture shown.
Distributor should be connected to any terminal of CH1 toCH6 of the device with two-wire cables.
Caution: Make sure all the related equipment is power-off during the installation.
Installation
Before you begin:
Make sure the device in the package is in good condition.
Make sure all the related equipment is power-off during the installation.
Check the product specification for the installation environment.
Wall Mounting
1. Fix the DIN rail onto the wall.
Note: You are required to utilize a matched DIN rail.
2. Press the red clip upward, and lock it to the DIN rail.
Tips for Cables and Installation
Cables and Wiring
When there are multiple cores in one parallel line, only one pair of closed cores are allowed to
transmit signal. It is not allowed to use multiple pair of cores in one cable to transmit signal.
When using parallel lines, it is suggested to use those with shielding layer. If dual core or
multiple core parallel lines without shielding layer are routed, stability of signal transmission
can be effected. You need to run a test before installation.
Impedance of cable should not be over suggested value, or distributor cannot transmit
enough power to indoor station or door station.
Strong electricity and weak electricity cannot be wired in the same route, they need to be wired
separately and the distance should be more than 0.5 meter.
All the cables used need to follow the restriction in the following table.
Device Installation
Installation environment (temperature, moisture etc.) needs to follow requirements in
specification or power output can be effected.
Power supply must be certified by Hikvision.
Note:
The indoor station and doorstation are not contained in
the package.
Note: The power source should be qualified and meet limited power
source or PS2 requirements according to IEC 60950-1 or IEC 62368-1 standard.

Other documents for Hikvision DS-KAD706Y-S

The following documents are available:
Installation Instruction Specification Photos

Specifications