Hoshizaki DKM500BAJ DKM-500BAJ 30" Serenity Series Crescent Cube Ice Maker

User Manual - Page 22

For DKM500BAJ.

PDF File Manual, 29 pages, Read Online | Download pdf file

DKM500BAJ photo
Loading ...
Loading ...
Loading ...
22
B. Cleaning and Sanitizing Instructions
The appliance must be cleaned and sanitized at least once a year. More frequent
cleaning and sanitizing may be required in some water conditions.
WARNING
To prevent injury to individuals and damage to the icemaker, do not use ammonia
type cleaners.
• Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
NOTICE
The pump motor is energized continuously when the control switch is in the
"SERVICE" position.
1. Cleaning Procedure – Icemaker
1) Dilute 10.5 . oz. (311 ml) of Hoshizaki "Scale Away" with 2 gal. (7.6 l) of warm water.
2) Remove all ice from the evaporator.
Note: To remove cubes on the evaporator, remove the front panel and disconnect the
connector from the control box. See Fig. 7. Move the control switch on the control box to
the "OFF" position and move it back to the "ICE" position after 3 minutes. The harvest
cycle starts and the cubes will be removed from the evaporator.
3) Reconnect the connector from the front panel to the control box and replace the front
panel in its correct position. Dispense all of the ice from the storage bin.
Snap Pin
Shutter
Spout
Extension
Thumbscrew
Thumbscrew
Bin Cover
Grill
Chute
Agitator
Bin
Control
Connector
Front
Panel
Spout
Bin Spout
Connector
Control
Box
Storage Bin
Fig. 7
Loading ...
Loading ...
Loading ...