PARAMETER VALUE DESCRIPTION
position
0~<motor_max>
Motor’s position.
It works only if function=focus and direction=direct.
<motor_max> is refer to
remote_focus_focus_motor_max which replied from
"function=getstatus"
steps 1 ~ <motor_max> Motor’s moving steps.
It works only if function=focus and direction=forward or
direction=backward.
<motor_max> is refer to
remote_focus_focus_motor_max which replied from
"function=getstatus"
* This parameter is for additional fine-tune, the value is from 1 to 30.
iris
N/A
Open iris or not.
It works only if function=auto or function=scan.
8.21 Export Files
Note: This request requires Administrator privileges.
Method: GET
Syntax:
For daylight saving time configuration file:
http://<servername>/cgi-bin/admin/exportDst.cgi
For language file:
http://<servername>/cgi-bin/admin/export_language.cgi?currentlanguage=<value>
PARAMETER
VALUE
DESCRIPTION
currentlanguage 0~20 Available language lists.
Please refer to:
system_info_language_i0 ~ system_info_language_i19.
For setting backup file:
http://<servername>/cgi-bin/admin/export_backup.cgi?backup