NAME VALUE SECURITY
(get/set)
DESCRIPTION
The dwelling time of each patrol point,
separated by “,”
* only available when
capability_camctrl_c0_rs485=2
preset_i<0~(k-1)>_nam
e
string[40] 1/4 Name of the preset location.
preset_i<0~(k-1)>_
dwelling
0 ~ 999
1/4
The dwelling time of each preset
location
* only available when
capability_camctrl_c0_rs485=2
uart 0 ~ "
capability_nuar
t"-1
1/4 Select corresponding uart
(capability_nuart>0).
* only available when
capability_camctrl_c0_rs485=2
cameraid
0~255
1/4
Camera ID controlling external PTZ
camera.
isptz 0 ~ 2 1/4 0: disable PTZ commands.
1: enable PTZ commands with PTZ
driver.
2: enable PTZ commands with UART
tunnel.
* only available when
capability_camctrl_c0_rs485=2
disablemdonptz
<boolean>
1/4
Disable motion detection on PTZ
operation.
7.41 Camera PTZ Control (IZ Series)
Group: camctrl_c<0~(n-1)> for n channel products
(capability_camctrl_c0_zoommodule = 1 and
capability_camctrl_c0_buildinpt = 0)
n denotes the value of "capability_nvideoin" and k denotes the value of "capability_npreset"
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
ccdtype string[16] 6/7 (Internal used, read only)
motortype
string[16]
6/7
(Internal used, read only)
cameraid 0 ~ 255 1/4 Camera ID controlling external PTZ