Axis 0647-001 ~ EOL Q2901-E Temperature Alarm Network Camera 19mm 0647-001

Axis Q2901-E User Manual - Page 63

For 0647-001 ~ EOL.

PDF File Manual, 67 pages, Read Online | Download pdf file

0647-001 ~ EOL photo
Loading ...
Loading ...
Loading ...
AXISQ2901-ETemperatureAlarmCamera
TechnicalSpecifications
TechnicalSpecifications
Function/group
Item
Specications
Model
AXISQ2901–E
ImagesensorUncooledMicrobolometer336x256pixels,pixelsize17µm
Spectralrange:8-14µm
Lens
9mm:f1.25FoVhorizontal35°,vertical27°;min.focusdistance:2.1m(78.7in)
19mm:f1.25FoVhorizontal17°,vertical13°;min.focusdistance:9.5m(354.3in)
Temperature
detectionrange
Thesizeofamonitoredobjectisrecommendedtocoveratleast10x10pixelsin336x256.
Camera
Sensitivity
NETD<50mK
Object
temperature
range
-40to600°C(-40to11 12°F)
Thermography
Temperature
accuracy
Below100°C(212°F):+/-5°C(+/-9°F)accuracy
Below150°C(302°F):+/-5%accuracy
Over150°C(302°F):+/-20%accuracy
Video
compression
H.264(MPEG-4Part10/AVC),H.264MainandBaselineProleMotionJPEG
Resolutions
Sensoris336x256.Imagecanbescaledupto720x576
FramerateUpto8.3fps
Videostreaming
3individualstreams*inH.264andMotionJPEG:simultaneous,individuallycongured
streamsinmax.resolutionat8.3fpsControllableframerateandbandwidth.VBR/CBR
H.264*3individualstreamswithsamepalette
Imagesettings
Automaticgaincontrol,Exposurezones,Gain,Rotation,Palette,Isothermalpalette,
Compression,Mirroring,Textandimageoverlay,Sharpness,AxisCorridorFormat
PaletteWhite-hot
Black-hot
Planck
Axis
Rainbow
Red-hot
Nightvision
Video
IsothermpaletteIso-Fire-WH
Iso-Fire-BH
Iso-Planck-WH
Iso-Axis-WH
Iso-Midrange-WH
Iso-Midrange-BH
Iso-Rainbow-WH
AudiostreamingTwo-way,Fullduplex
Audio
compression
AACLC8/16kHz
G.711PCM8kHz
G.726ADPCM8kHz
Congurablebitrate
Audio
Audio
input/output
Externalmicrophoneorlineinput,lineoutput