Napoleon LEX485RSIBNSS1 Lex Series 62 Inch Freestanding Natural Gas Grill with Standard Burners, 815 sq. inches Grilling Surface Size, Warming Rack, Side Burner, Side Table, Jetfire Ignition System, Accu-Probe, i-GLOW Backlit, Ceramic Infrared Rear B

User Manual - Page 6

For LEX485RSIBNSS1.

PDF File Manual, 64 pages, Read Online | Download pdf file

LEX485RSIBNSS1 photo
Loading ...
Loading ...
Loading ...
www.napoleongrills.com
6
EN
Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng: This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
Natural Gas Hook-Up
This natural gas grill is supplied with a 10 supply hose (complete with a quick disconnect) designed
for natural gas and cered for outdoor use. The gas grill is designed to operate at an inlet pressure
of 7 inches water column. Piping and valves upstream of the quick disconnect are not supplied. The
installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run.
The quick disconnect must not be installed in an upward direcon and a readily accessible manual shut-
o valve must be installed upstream of, and as close to, the quick disconnect as is feasible. The ared end
of the hose must be connected to the ng on the end of the ex tube as illustrated in the Natural Gas
Hose Aachment diagram. Tighten using two wrenches. (Do not use thread sealer/pipe dope.) These
connecons must be made by a licensed gas installer. Leak test all joints prior to using the gas grill.
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak tested
before operang the grill.
Do not route hose underneath drip pan.
Do not route hose between space in boom shelf and back panel.
Do not route hose over top of back panel.
Ensure all hose connecons are ghtened using two wrenches. Do not use teon tape or pipe dope
on any hose connecon.
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a
re.
Do not use enclosure to store excess hose, as there is a greater chance of the hose contacng a hot
surface, it may melt and leak causing a re.
Leak test all the connecons using a soap and water soluon, as per the leak tesng instrucons
found in the this manual.