This unit requires a standard 110 Volt AC ~ 60Hz three-prong grounded electrical outlet. Have the
wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.
When a standard 2-prong wall outlet is encountered, it is your responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.
To prevent accidental injury, the cord should be secured behind the unit and not left exposed or
dangling.
The unit should always be plugged into its own individual electrical outlet which has a voltage rating
that matches the rating label on the unit. This provides the best performance and also prevents
overloading house wiring circuits that could cause a fire hazard from overheating. Never unplug the
unit by pulling on the power cord. Always grip the plug firmly and pull it straight out from the
receptacle. Repair or replace immediately all power cords that have become frayed or otherwise
damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end.
When moving the equipment, be careful not to damage the power cord.
Electrical Connection
Because of potential safety hazards under certain conditions, it is strongly recommended that you do
not use an extension cord with this equipment. However, if you must use an extension cord it is
absolutely necessary that it be a UL/CUL-Listed, 3-wire grounding type equipment extension cord
having a grounding type plug and outlet and that the electrical rating of the cord be 115 volts and at
least 10 amperes.
Reversing the Door
Unless ordered as an “LHD” variant, your unit is shipped with a right-hand self-closing door swing. If
you wish to reverse the door to open from the opposite direction, follow the steps listed below.
NOTE: Doors on units with DL2B” data loggers are not reversible.
1. Carefully lay the unit on its back and remove the two front leveling legs
2. Remove the two hex head screws that connect the door hinges to the body on the bottom of the
unit
3. Remove the two flathead screws that connect the hinge assembly to the bottom of the door
4. Remove the white hinge from the square rod
5. Slide the door towards the bottom until it is free of the top hinge
6. Unscrew the top hinge pin from the unit and reinstall it on the left side
7. Flip the door so the handle is now on the right side
8. Push the door onto the top hinge piece.
9. Reinstall the hinge assembly on the left side bottom of the door using the flathead screws
10. Push the white hinge onto the square rod at an angle of 90 degrees
11. Turn the white hinge clockwise until the holes line up with screws located on the bottom of the
unit
12. Replace the hex head screws and front leveling legs
NOTE: Once the door has been reversed, the Pharma-Vac or Med-Lab sticker will be upside down.
You can remove and reapply to the preferred position. If you would like a replacement
sticker, contact our parts department at parts@summitappliance.com.
CAUTION: After setting the unit upright you MUST allow this unit to stand upright for at least 2 hours
to allow the lubricant and refrigerant to drain back into the compressor and stabilize.
Failure to do so may adversely affect performance and the lifetime of this unit.