Delta 96110 10 In. Cruzer Wet Tile/stone Saw

Instruction Manual - Page 16

For 96110.

PDF File Manual, 21 pages, Read Online | Download pdf file

96110 photo
Loading ...
Loading ...
Loading ...
16 17
MAINTENANCE
For your safety, turn off the switch and unplug saw from the power source before performing any maintenance or
cleaning. If the power cord becomes damaged in anyway, replace it immediately with the approved cord. When
cleaning the saw, do not expose the motor to direct water. If excessive water is introduced into the motor, electric
shock and/or damage to the motor can occur.
Do not service the electric motor’s internal components yourself. Contact an authorized service center.
Never use water or any other chemical liquids to clean the electrical parts of the machine.
Use a soft cloth to clean off the water and dust from the machine.
Keep the ventilation slots of the motor clean to prevent overheating.
Periodic maintenance of your tile saw allows for long life and trouble-free operation. The cutting residue that the saw generates
could be considerable. A cleaning, lubrication, and maintenance schedule should be maintained.
As a common sense and preventative maintenance practice after each use, follow these recommended steps:
Clean the entire saw with fresh water after each use.
Pump clean/fresh water for 1 minute through the water pump and blade guard
assembly to safeguard against slurry build-up and clogging.
Make sure the guide rails are lubricated.
If the table is not sliding easily, lubricate the bar lightly.
Inspect the cutting wheel for its overall integrity. Check the rim for wear or damage and replace cutting wheel if necessary.
Changing the Saw Blade
1. Loosen the blade cover lock knob (A, Fig. 27).
2. Swing the blade cover (6) open
3. Locate the supplied blade wrench on the saw arm assembly.
4. Depress the blade spindle lock (B, Fig. 26) and use the
blade wrench (C, Fig. 27) to loosen the arbor lock nut (D, Fig.
27)
5. Remove the arbor lock nut.
6. Remove the blade.
7. Place the new blade on the arbor so that the arrow on the
blade is pointing in the same direction as the arrow on the
blade cover. (See Figure 27)
8. Replace the arbor nut and tighten while depressing the
spindle lock.
9. Close the cover and tighten the cover lock knob.
Figure 26
Figure 27
B
A
C
D
Loading ...
Loading ...
Loading ...