20 BRIGGSandSTRATTON.COM
Cleaning the Generator
Clean the unit whenever dust, dirt, oil, moisture, or other
foreign material is visible on its exterior or interior surfaces.
The air inlets and outlets on the enclosure must not become
clogged with snow, leaves, or any other foreign material. To
prevent generator damage caused by overheating, keep the
air inlets and outlets clean and unobstructed at all times.
NOTICE DO NOT use direct spray from a garden hose to
clean generator. Water can enter the engine and generator
and cause damage.
1. Stop the generator.
2. Disconnect the negative ( - ) cable at the battery.
3. Clean generator as follows:
Use a damp cloth to wipe exterior surfaces clean.
Use a soft, bristle brush and vacuum cleaner to loosen
and pick up dirt and debris.
Use low pressure air (not to exceed 25 psi) to blow
away dirt and debris.
Clean the air inlets and outlets of any snow, leaves,
or debris. To prevent generator damage caused
by overheating, these openings must be kept
unobstructed.
4. Connect the negative ( - ) cable at the battery.
5. Set the generator mode to AUTO.
Maintenance
Engine Air Cleaner
1. Stop the generator.
2. Disconnect the negative ( - ) cable at the battery.
3. Remove filter cartridge.
4. Clean outlet tube and check Vacuator™ valve (if
equipped) - Use a clean cloth to wipe the filter sealing
surface and the outlet tube surfaces. Make sure that
all contaminant is removed before the new filter is
inserted. Be careful to not damage the sealing area on
the tube.
Visually check and physically squeeze Vacuator valve
attached to service cover to make sure it is flexible and
not inverted, damaged or plugged.
5. Clean filter - Use a soft bristle brush to loosen dirt and
a vacuum cleaner to remove dirt and debris. Replace
filter cartridge if any holes are detected in filter media.
6. Install clean filter properly - Insert the filter carefully.
Seat the filter by hand, making certain it is completely
into the air cleaner housing before securing the cover
in place.
7. Reinstall service cover. Make sure that all mounting
bands, clamps, bolts, and connections in the entire air
cleaner system are tight and verify absence of holes in
piping - repair if needed.
8. Connect the negative ( - ) cable at the battery.
9. Set the generator mode to AUTO.