Kobe CH7736SQ6XX Premium Series 36 Inch Under Cabinet Ducted Hood with 600 CFM, LED Lights, QuietMode, Delay Off, ECO Mode, Perimetric Extraction, VENTelligent in Stainless Steel

User Manual - Page 13

For CH7736SQ6XX.

PDF File Manual, 30 pages, Read Online | Download pdf file

CH7736SQ6XX photo
Loading ...
Loading ...
Loading ...
10
Wiring to Power Supply
THIS RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE BY
QUALIFIED ELECTRICIAN IN ACCORDANCE
WITH ALL APPLICABLE NATIONAL AND
LOCAL ELECTRICAL CODES. BEFORE
CONNECTING WIRES, SWITCH POWER OFF AT
SERVICE PANEL AND LOCK SERVICE PANEL
TO PREVENT POWER FROM BEING SWITCHED
ON ACCIDENTALLY.
4. If hood is operating normally, connect three
wires (black, white and green) to house wires
and cap with wire connectors.
5. Store wires in wiring box.
Ductwork Installation
6. Use steel pipe to connect the exhaust on the
hood to the ductwork. Use duct tape to make
all joints secure and air tight.
Duct Cover Installation
7. Mark the position of the Duct Cover-Mounting
Bracket {G}. Use reference E from TABLE 2
and measurements on page 16-17. Attach and
secure Duct Cover-Mounting Bracket {G} with
two screws (provided). Refer to Figure 12.
NOTE: Inner duct cover will cover the Duct
Cover-Mounting Bracket.
8. Position the entire duct cover up onto the hood.
9. Secure the inner duct cover with two (3/16” x
3/8”) screws {I} to the Duct Cover-Mounting
Bracket {G}. Shown in Figure 13.
10. Secure the outer duct cover with two (3/16” x
3/8”) screws {I} to the Blower Housing.
Install / Uninstall Accessories
11. Place the airflow efficiency panel underneath
the hood. (Figure 14)
Final Assembly
12. Turn power ON in control panel. Check all lights
and fan operation.
13. Leave this Installation Instructions and
Operation Manual for the homeowner.
Figure 12
Figure 13
Figure 14
Attach Together
Loading ...
Loading ...
Loading ...