FLUKE SMFT-1000/KIT SMFT-1000 Multifunction PV Tester and Performance Analyzer Kit with irradiance meter and current clamp, 1000 V, 20/400 A

User Manual for the Fluke SMFT-1000 Multifunction PV Tester and Performance Analyzer Kit with irradiance meter and current clamp, 1000 V, 20/400 A - Page 7

For SMFT-1000/KIT.

PDF File Manual, 48 pages, Read Online | Download pdf file

SMFT-1000/KIT photo
Loading ...
Loading ...
Loading ...
Multifunction PV Analyzer
Specifications
3
Vibration ............................................................. MIL-PRF-28800F: Class 2
Ingress Protection .......................................... IEC 60529:IP40
Computer Interface........................................ IR (serial) and Bluetooth
Wireless connection compatibility.......... IRR2-BT
Accuracy
The accuracy specification is defined as ± (% reading + digit counts) at 23
o
C ± 5
o
C, 80 % RH.
The accuracy specification for 0
o
C to 18
o
C and 28
o
C to 50
o
C: 0.1 x (accuracy specification)
for each °C.
Protective Conductor Resistance R
LO
PV Model/PV String, Open-Circuit Voltage, (V
OC
)
PV Model/PV String, Short-Circuit Current, (I
S/C
)
Display Range Measurement Range Resolution Accuracy
0.00 Ω to 19.99 Ω 0.20 Ω to 19.99 Ω 0.01 Ω ± (2 % + 2 Digit)
20.0 Ω to 199.9 Ω 20.0 Ω to 199.9 Ω 0.1 Ω ± (2 % + 2 Digit)
200 Ω to 2000 Ω 200 Ω to 2000 Ω 1 Ω ± (5 % + 2 Digit)
Test current
200 mA (2 Ω + R
COMP
)
[1]
Te s t v o l t a g e
4 V
DC
to 10 V
DC
Polarity reversing Yes
Test lead zero (Rcomp) up to 3 Ω
Live circuit detection
Inhibits test if terminal voltage >50 V ac/dc (typical) detected prior to initiation
of test.
[1] The number of 200 mA @ 0.1 Ω continuity tests with a set of new batteries is >1000.
Display Range Measurement Range Resolution Accuracy
0.0 V to 99.9 V 5.0 V to 99.9 V 0.1 V
± (0.5 % + 2 Digit)
100 V to 1000 V 100 V to 1000 V 1 V
Polarity test Yes
Live circuit detection Inhibits test if terminal voltage >5 V ac detected prior to initiation of test.
Display Range Measurement Range Resolution Accuracy
0.0 A to 20.0 A 0.2 A to 20.0 A 0.1 A ± (1 % + 2 Digit)
Live circuit detection Inhibits test if terminal voltage >5 V ac (typical) detected prior to initiation of test.