Video Intercom Module Door Station·User Manual
2. Select the device type from the drop-down list, and set the corresponding
information.
3. Click the Save button to enable the device number configuration.
For main door station, the serial No. is 0.
For sub door station, the serial No. is higher than 0. Serial No. ranges from 1 to 99.
For each villa or building, at least one main door station should be configured, and
sub door stations can be customized.
For one main door station, at most 8 sub door stations can be customized.
5.6.2 Time Parameters
1. Click the Time Parameters button to enter time parameters settings interface.
2. Configure the maximum ring duration, maximum live view time, and call forwarding
time.
3. Click the Save button.
For door station, maximum speaking time and maximum message time should be
configured. Maximum speaking time varies from 90s to 120s, and maximum message
time varies from 30s to 60s.
5.6.3 Access Control and Elevator
Click Access Control and Elevator to enter corresponding configuration page.