Axis 0820-001 A9188 Network Relay I/O Module

Axis A9188 Installation Guide - Page 20

For 0820-001.

PDF File Manual, 26 pages, Read Online | Download pdf file

0820-001 photo
Loading ...
Loading ...
Loading ...
AXISA9188NetworkI/ORelayModule
Function
Specications
PowerandEthernet
PoweroverEthernetPlus(PoE+)IEEE802.3atType2Class4,
44–57VDC
SupervisedI/OandPowerConnector
7-pincongurableI/Oterminalblockfor:
Auxiliarypower(DCoutput)
DigitalInput
DigitalOutput
Supervisedinput
0VDC(-)
Foranexampleconnectiondiagram,seeConnectionDiagramsonpage
25.
FunctionPinNotes
Specications
0VREF
1
0VREF
12VDC
output
2
Forpoweringauxiliary
equipment.
Note:Thispincanonlybe
usedaspowerout.
SeePowerConsumptiononpage
18
24VDC
output
3
Forpoweringauxiliary
equipment.
Note:Thispincanonlybe
usedaspowerout.
SeePowerConsumptiononpage
18
DigitalinputConnectto
pin1toactivate,orleave
oating(unconnected)to
deactivate.
0tomax40VDC
Congurable
(Inputor
Output)
4–7
DigitaloutputConnectto
pin1toactivate,orleave
oating(unconnected)to
deactivate.Ifusedwithan
inductiveload,e.g.arelay,
adiodemustbeconnected
inparallelwiththeload,for
protectionagainstvoltage
transients.
0tomax40VDC,opendrain,
100mA
20