11
12. ALARMS SHOWN ON DISPLAY
ALARM CAUSE SOLUTION
Tank (A6) missing or incorrectly
positioned
Place the tank back in its correct position (see para-
graph “3.1 Draining into the tank”)
Tank full Empty the tank (see paragraph “3.1 Draining into the
tank”)
Room temperature too low (see op-
erating limits in chap. “6. Technical
Specications”)
Increase the room temperature if possible
Humidity in room too low or too high for
correct measuring (see operating limits
in chap. “6. Technical Specications”)
Move the appliance to another room with humidity
and temperature levels within the operating limits: if
the problem persists, call the Service Centre.
Faulty probe Call Service Centre
Wi-Fi interface not working properly Turn the appliance o and disconnect the plug from
the power socket. Wait a few minutes, then re-insert
the plug: if the problem persists, contact the Service
Centre.
After a preset number of operating hours,
the symbol (C2) blinks on the display
to indicate that the HEPA-type (E12)*
lter (A7) needs to be replaced.
Replace the HEPA-type (E12)* lter (see para. “10.3
Replacing the HEPA-type (E12)* lter”).
If the HEPA-type (E12)* lter has recently been re-
placed, reset the alarm (see para. “10.3 Replacing the
HEPA-type (E12)* lter”)
13. TROUBLESHOOTING
Below is a list of possible malfunctions.
If the problem cannot be resolved using the proposed solution,
contact the Service Centre.
PROBLEM CAUSE SOLUTION
The appliance is operating in dehumid-
ifying mode, but the humidity does not
decrease
The lter is clogged Clean the dust lter (para. “10.2 Cleaning
the dust lter”) and check whether the
HEPA-type (E12)* lter needs replacing
(see paragrah. “10.3).
Either the temperature or humidity in the
room is too low
In certain conditions the appliance will
not dehumidify: check the operating lim-
its of the appliance (see chap. “6. Techni-
cal Specications”). In certain cases, it is
recommended to heat the room needing
to be dehumidied.
The set relative humidity level is too high Set a lower humidity value (see para-
graph “4.1 Dehumidifying mode”).