Examples:
Avoid triggering on small objects by setting the object size level to high.
Use several small Motion Detection windows rather than one large window, if triggers on small movements or
objects are desired.
To reduce the number of triggers if there is a lot of movement during a short period of time, select a high history
level.
To only detect flashing light, select low sensitivity. In other cases, a high sensitivity level is recommended.