Category Gas Type
Burner Wok Rapid Semi-Rapid Auxiliary
Rated Power
(kW)
3.6 3.0 1.75 1.0
I3+
G30/G31
28-30/37 mbar
Rated Flow
(g/h)
263 219 127 73
Injector
Diameter(mm)
0.96 0.87 0.66 0.50
I2H/I2E/I2E+
Natural Gas
20 mbar
Injector
Diameter(mm)
1.44 1.30 1.00 0.78
II2H3+
G30/G31
28-30/37 mbar
Injector
Diameter(mm)
0.96 0.87 0.66 0.50
Natural Gas
20 mbar
Injector
Diameter(mm)
1.44 1.30 1.00 0.78
II2E3B/P,
II2H3B/P
L.P.G (G30, G31
(28-30)mbar
Injector
Diameter(mm)
0.96 0.87 0.66 0.50
Natural Gas
20 mbar
Injector
Diameter(mm)
1.44 1.30 1.00 0.78
• If you want to process gas conversion, all work must be carried out by a qualied technician.
• When converting to LPG, use the injector sizes shown in the table above.
• After gas conversion, it is strongly suggested to tick the correct gas category on the product rating
label for clarication.
• Note: This product is supplied ready for connection to Natural Gas. A conversion kit is available from
our Spares Store, to allow connection to LPG. Contact details can be found at the front of this User
Guide.
• Appliance Class - Class 3 Built-In Hotplate.
• Note: Conversion kits are available from our Spares Store. Contact details can be found at the front
of this User Guide.
Gas hob
TECHNICAL DATA