Hoshizaki PT2AFSFS PT2A-FS-FS 55" Steelheart Series Two-Section Pass-Thru Refrigerator with 52.5 cu. ft. Capacity, Full Solid Doors, Unique Ducted Air Distribution System and LED Lighting in Stainless Steel

User Manual - Page 33

For PT2AFSFS.

PDF File Manual, 48 pages, Read Online | Download pdf file

PT2AFSFS photo
Loading ...
Loading ...
Loading ...
33
G. Electrical Connection
WARNING
• Electrical connection must meet national, state, and local electrical code
requirements. Failure to meet these code requirements could result in death,
electric shock, serious injury, re, or severe damage to equipment.
This appliance requires an independent power supply of proper capacity. See
the nameplate for electrical specications. Failure to use an independent power
supply of proper capacity can result in a tripped breaker, blown fuse, damage to
existing wiring, or component failure. This could lead to heat generation or re.
115VAC Models: THIS APPLIANCE MUST BE GROUNDED: This appliance
is equipped with a NEMA 5-15 three-prong grounding plug to reduce the
risk of potential shock hazards. It must be plugged into a properly grounded,
independent 3-prong wall outlet. If the outlet is a 2-prong outlet, it is your personal
responsibility to have a qualied electrician replace it with a properly grounded,
independent 3-prong wall outlet. Do not remove the ground prong from the plug
and do not use an adapter plug. Failure to follow these instructions may result in
death, electric shock, or re.
208/230VAC Models: THIS APPLIANCE MUST BE GROUNDED: This appliance
is equipped with a NEMA L14-20 four-prong locking, grounding plug to reduce
the risk of potential shock hazards. It must be plugged into a properly grounded,
independent 4-prong wall outlet. If the outlet is a 3-prong outlet or a 4-prong
non-locking outlet, it is your personal responsibility to have a qualied electrician
replace it with a properly grounded, independent 4-prong locking wall outlet. Do
not remove the ground prong from the plug and do not use an adapter plug. After
plugging in, twist the plug clockwise to lock it into place. Failure to follow these
instructions may result in death, electric shock, or re.
To reduce the risk of electric shock, do not touch the plug with damp hands.
• Press and hold the standby button to turn "OFF" before unplugging the appliance
to reduce the risk of electric shock.
• Do not use an extension cord.
• Do not use an appliance with a damaged power cord. The power cord should not
be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions
could result in electric shock or re. To unplug the appliance, be sure to pull the
plug, not the cord, and do not jerk the cord.
The GREEN ground wire in the factory-installed power cord is connected to the
appliance. If it becomes necessary to remove or replace the power cord, be sure
to connect the power cord's ground wire.
• Usually an electrical permit and services of a licensed electrician are required.
The maximum allowable voltage variation is ±10 percent of the nameplate rating.
Loading ...
Loading ...
Loading ...