Pelco IMD15118 3x5MP Up to 180° Multi-Directional Camera

Pelco Sarix Multi-Pro Installation User Manual - Page 21

For IMD15118.

PDF File Manual, 62 pages, Read Online | Download pdf file

IMD15118 photo
Loading ...
Loading ...
Loading ...
Sari Multi Pro Camera Installation Manual
C6715M | 01/24/22
21
Connecting Cables
Refer to the diagrams in the Overview section for the location of the different connectors.
To connect the cables required for proper operation, complete the following:
1. Feed the network cable through the gland cap and cable gland. Crimp the RJ-45 cable connector
(supplied) to the end of your network cable.
The network cable connection can also be used to supply power to the camera using Power over
Ethernet (PoE). If using PoE, connect a PoE compliant injector or switch to the Ethernet network
cable with the output rated:
l With IR Ring: 60W PoE mid-span injector (PD-9501GR/AC-NA-MSI and include POE190-BT).
Alternatively, connect to a Cisc UPoE capable switch, supporting 60W over 4 pairs. Note
that the Cisco switch must be configured with the Force Four Pair option enabled.
l Without IR Ring: Power over Ethernet (PoE) Plus, PD-9001GR/AT/AC-MSI, IEEE 802.3at
Class 4 Connect a PoE Plus compliant injector or switch (e.g. POE430-AT, POE1236-AT, or
POE2436-AT).
Note: When on UPoE and without an IR ring, the Sarix Multi Pro will continue to request
60W power on startup, as the IR ring is a hot-pluggable add-on accessory. If the IRring
accessory will never be used, the recommendation is to limit the available power to PoE
plus equivalent on the Cisco switch settings.
2. Connect the following optional connections to the supplied pigtail I/O connector. See Connecting to
Power, Audio, and External Devices for more information on the different connections.
a. If external input or output devices are part of the installation (for example: door contacts,
relays, etc.), wire those devices to the pigtail connector.
b. If an external microphone or speaker is required, connect the devices to the pigtail connector.
c. If external power is required, connect an external "Class 2" or "LPS" or "Limited Power Source"
to the pigtail connector with output rated: