3. General CGI URL Syntax and Parameters
CGI parameters are written in lower-case and as one word without any underscores or other separators. When the
CGI request includes internal camera parameters, these parameters must be written exactly as they are named in
the camera or video server. The CGIs are organized in functionally-related directories under the cgi-bin directory.
The file extension .cgi is required.
Syntax:
http://<servername>/cgi-bin/<subdir>[/<subdir>...]/<cgi>.<ext>
[?<parameter>=<value>[&<parameter>=<value>...]]
Example: Set digital output #1 to active
http://mywebserver/cgi-bin/dido/setdo.cgi?do1=1
4. Security Level
SECURITY LEVEL SUB-DIRECTORY DESCRIPTION
0 anonymous Unprotected.
1 [view] anonymous, viewer,
dido, camctrl
1. Can view, listen, talk to camera.
2. Can control DI/DO, PTZ of the camera.
4 [operator] anonymous, viewer,
dido, camctrl, operator
Operator access rights can modify most of the camera’s
parameters except some privileges and network options.
6 [admin] anonymous, viewer,
dido, camctrl, operator,
admin
Administrator access rights can fully control the camera’s
operations.
7 N/A Internal parameters. Unable to be changed by any external
interfaces.