Maintenance
English
62
4. Check if there is any leak. If not, x the
lines with the clips.
5. Put the water lter into place and x it
with the clips.
6. Press and hold Filter Reset for 3
seconds to reset the lter lifecycle.
7. When replacing is complete, ush 1 litre
of water to remove impurities from the
water line.
CAUTION
When adjusting the length of the water
line tubing, make sure to smooth out the
cut surface at a right angle. This is to
prevent a water leak.
NOTE
• A newly installed lter may cause the water dispenser to spurt water briey. This is
because air has entered the water line.
• This replacement process may involve the refrigerator to drip water onto the oor. If
this happens, wipe up with dry cloths.
Reverse osmosis water ltration system
The water pressure of the water supply system to a reverse osmosis water ltration
system must be between 206 kPa (30 psi) and 861 kPa (125 psi).
The water pressure of the reverse osmosis water ltration system to the refrigerator’s
cold water line must be at least 206 kPa (30 psi). If the water pressure is below the
specied:
• Check if the sediment lter in the reverse osmosis system is blocked. Replace the lter
if necessary.
• Rell the water tank in the reverse osmosis system with water.
• If your refrigerator has a water lter, it may further reduce the water pressure when
used in conjunction with a reverse osmosis system. Remove the water lter.
For more information or servicing, contact a licensed plumbing professional.