EN
By modifying the amount of
American/French press coffee
ground, for the 2-cup selection, the
amount of espresso coffee for the
other pre-set functions present on the
knob is modied automatically (from
2 to 12).
Resetting factory values
To reset the factory values:
Turn the knob (7) onto program “12”.
Press the START/STOP button (6) and hold
it down for 5 seconds. The lock-nut (14)
ashes 5 times indicating that all factory-
set values have been reset (for Espresso
functions and Filter Coffee/French Press
functions).
Cleaning and maintenance
CLEANING AND MAINTENANCE
(Fig. A-H-I-L)
Make sure the coffee bean container (2) is
empty and then run in manual mode (M) to
remove any coffee residue from the grinder.
Before carrying out any cleaning
operation, ALWAYS disconnect the
plug from the power outlet.
Never immerse the motor base (1)
in water or other liquids.
Remove the container (2) by turning it
counter-clockwise.
Remove any coffee beans present in the
machine using the cleaning brush (10)
supplied.
Lift the handle (15) and turn the upper
grinder (9a) counter-clockwise to release it
and then remove it.
Clean the upper grinder (9a) and the lower
grinder (9b) and the coffee outlet cavity
using a hard bristle brush or the supplied
cleaning brush (10).
Re-mount the upper grinder (9a) making the
two notches “ ” “ ” correspond and
rotating clockwise to x it “ ” “
The ground coffee bean container (2,4), the
lid (3), and the plate (5) can be washed
using warm water and neutral detergent.
The motor base (1) can be cleaned using a
damp cloth, avoiding the use of detergents
or abrasive materials
.