Holmes HUL9500B-U-FCA-2 Ultrasonic Cool and Warm Mist Humidifier

Product's Documents

Below are documents related to this product, you can read online or download:
HUL9500B-U-FCA-2 photo

Owner’s Guide

This is the main product document for model HUL9500B-U-FCA-2. Additionally, the document applies to other Holmes models: HUL9500B

The file format is pdf, 8 pages, you can download this manual here .

background
WARRANTY INFORMATION
3 YEAR LIMITED WARRANTY
Sunbeam Products, Inc. (“Sunbeam”) or if in Canada, Newell Brands Canada ULC (“NBC”) warrants that for a period of one
(3) years from the date of initial retail purchase, this product will be free from defects in material and workmanship, when
used in accordance with the instructions provided.
Sunbeam (or NBC), at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period.
Replacement will be made with a new or remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT attempt
to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep
the original sales receipt. Proof of purchase is required to obtain warranty performance. Sunbeam (or NBC) dealers, service
centers, or retail stores selling Sunbeam (or NBC) products do not have the right to alter, modify or any way change the
terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of
the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration
by anyone other than Sunbeam (or NBC) or an authorized Sunbeam (or NBC) service center. Further, the warranty does not
cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on Sunbeam’s (or NBC’s) Liability?
Sunbeam (or NBC) shall not be liable for any incidental or consequential damages caused by the breach of any express, implied
or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or condition of
merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Sunbeam (or
NBC) disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise. Sunbeam (or NBC)
shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product
including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract, fundamental or
otherwise, or for any claim brought against purchaser by any other party. Some provinces, states or jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights that vary from province to province, state to state or jurisdiction to jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In Canada
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. located in Boca Raton, Florida 33431. In Canada, this warranty
is offered by Newell Brands Canada ULC, located at 20B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any other
problem or claim in connection with this product, please write our Consumer Service Department.
PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
©2019 Sunbeam Products, Inc. All rights reserved.
TROUBLESHOOTING
STORAGE INSTRUCTIONS
FREQUENTLY ASKED QUESTIONS
TROUBLESHOOTING
Trouble Probable Cause Solution
Water Leaks from
Tank.
Tank/cap gasket is missing.
Unit tilted or not leveled.
Cap not tight enough.
Tank water is Hot.
Remove tank cap and replace or reposition
gasket.
Place unit it on a flat or leveled surface.
Tighten the cap.
Fill with cool water only.
Crack in Tank.
Hot water will cause tank to pressurize.
Tanks will crack if hit or dropped.
Fill with cool water only.
Handle tank with care. If there is crack on
tank, replace with a new tank.
Film on Tank.
Mineral deposits.
Clean/disinfect tank as instructed in weekly
cleaning instructions.
Mist output
minimal to none.
Scale build up on transducer. Replace the dimineralization cartridge by
following the maintenence instructions.
Reduced or no mist.
Out of water.
Improper Maintenance.
Demineralization cartridge not seated
properly.
Using low setting.
Fill tank.
Increase setting to High.
Properly seat the demineralization cartridge and
reseat tank.
Follow cleaning and maintenance instructions.
Appearance of
minerals or white
dust.
The demineralization cartridge is
assembled upside down and the tank
will not sit flush. This prevents the tank
plunger value from being activated to
all water to flow.
Use distilled water in your humidifier. This will
help reduce the precipitation of minerals or white
dust.
In addition, use a demineralization cartridge to
help reduce mineral build-up and “white-dust”
caused by hard water.
Tank does not fit
properly on the
base.
The demineralization cartridge is not
seated correctly in the base.
Confirm the proper placement of the
demineralization cartridge. The cartridge is
marked with "THIS SIDE UP".
FREQUENTLY ASKED QUESTIONS
Question Answer
What are the
variables that affect
run time?
The estimated run time for this humidifier is based on average room conditions. The actual run time
of your humidifier is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room where the humidifier
is placed.
Home furnishings in the room where the humidifier is placed.
How do I remove
film on water tank?
Vinegar and water soak will remove it within 20 mins.
How can I extend
the run time?
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit will turn on and off,
which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into the base until it stops
bubbling, then refill the tank full again. This ensures maximum water capacity and will extend
run time.
If you have any questions regarding your product or would like to learn more about other Holmes
®
products, please visit
our website at www.holmesproducts.com. For inquiries regarding recycling and proper disposal of this product, please
contact your local waste management facility.
199410 HUL9500B_19EM1 Printed In China
GCDS-HOL635678-JC
4. To rinse, pour 1 cup of cool tap water in the air inlet
area. Allow to reach transducer area. Pour out water.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon (0.25oz/7.4ml) of chlorine bleach.
2. Return tank to base. Allow to set for 20 minutes. Use
clean water in tank to flush system. Do not allow
water to get in the fan housing.
3. Carefully empty the tank after 20 minutes, and rinse
with warm water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
4. Discard bleach water in the base. pour towards the
left corner of base.
5. To clean the humidifier base, pour out all access
water. Rinse thoroughly to remove any sediment to
dirt. Wipe clean and dry with a clean cloth or paper
towel. Do not use metal cleaning utensils of abrasive
cleansers.
NOTE: Do not scrape the transducer with any other object
other than the brush provided. Damage could occur and
cause malfunction.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period
of time:
1. Clean, rinse and thoroughly dry the humidifier as
directed in weekly maintenance. DO NOT leave any
water in the unit when storing. Leaving water in the
unit may render the unit inoperable for the following
season.
2. Place the humidifier in the original carton and store
in a cool, dry place.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of
the following:
Visit your local retailer
Go to
www.holmesproducts.com
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Owner’s Guide
HUL9500B
Warm or Cool Ultrasonic
Humidifier
HUL9500B_19EM1.indd 1 5/21/19 10:10
background
IMPORTANT SAFEGUARDS
FEATURES - OPERATIONS
18. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer, available
at your local retailer, to measure the humidity.
19. Never operate unit without water in the tank. Do not
pour water in any openings other than the water tank.
For warm mist models:
20. WARNING: Hot steam can cause serious burn
injuries. Keep away from steam while in operation,
especially children. Do not allow children access to
the appliance during operation.
21. Allow unit to cool before refilling water tank or
maintenance, as the heater bulb is hot.
22. Do not attempt to remove the water tank within 15
minutes after the humidifier is turned off and
unplugged. Serious injury may result.
SAVE THESE
INSTRUCTIONS
HOUSEHOLD USE ONLY
POWER CORD INSTRUCTIONS:
A short power-supply cord or detachable power-supply
cord is provided to reduce risks resulting from becoming
entangled in or tripping over a longer cord. Longer
detachable power-supply cords or extension cords are
available and may be used if care is exercised in their
use. If a long detachable power-supply cord or extension
cord is used on short-cord models:
a. The marked electrical rating of the detachable power-
supply cord or extension cord should be at least as
great as the electrical rating of the appliance;
b. When the product is of the grounded type, the extension
cord shall be a grounding type 3-wire cord; and
c. The longer cord should be arranged so that it will not
drape over the counter top or table top where it can
be pulled on by children or tripped over
unintentionally.
Do not pull, twist or otherwise abuse the power cord.
Do not wrap the power cord around the main body of the
appliance during or after use.
NOTICES
1. Do not allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wallpaper.
2. Keep unit away from surfaces that can be damaged
by water and/or heat (such as wood floors). Place
mat underneath the unit during use. Do not place
humidifier under overhanging surfaces.
3. Do not place the humidifier on a rug or carpet. The
heat sink underneath the humidifier might cause the
carpet to be discolored and may cause overheating of
the unit.
4. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
FCC STATEMENT
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
This product has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 18
of the FCC rules.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
The product generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that the interference will not occur in a
particular installation. If the product does cause harmful
interference to radio or television reception, which can be
determined by turning the product on or off, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the product and the
receiver.
Connect the product into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the
following:
1. Read all instructions before using the appliance.
2. To protect against electric shock, do not place or
immerse cord, plugs, or appliance in water or other
liquid. Do not plug in the cord with wet hands. Do
not overfill the water tank.
3. Plug the appliance directly into a 120VAC electrical
outlet.
4. This appliance is not intended for use by children or
by persons with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge.
Close supervision is necessary when any appliance is
used near children. Children should be supervised to
ensure that they do not play with the appliance.
Keep the appliance and its cord out of reach of
children.
5. Never place humidifier in an area where it is
accessible to children. Never use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. Keep the cord out of heavy traffic areas. To reduce
risk of fire, never put the cord under rugs or near
heat registers.
7. Do not operate any appliance with a damaged cord
or plug or after the appliance malfunctions, or has
been damaged in any manner. Do not attempt to
replace or splice a damaged cord. Return appliance
to the manufacturer (see warranty) for examination,
repair or adjustment.
8. Do not place on or near wet surfaces, or near heat
sources such as stoves, radiators, and heaters.
9. Place your humidifier on an inside wall near an
electrical outlet. The humidifier should be at least 4
inches (10 cm) away from the wall for best results.
10. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury.
11. Unplug from outlet when not in use, before putting
on or taking off parts and before cleaning. To
disconnect, turn any control to OFF, then unplug
power cord from outlet. Be sure to unplug the unit
by pulling on the plug and not the cord.
12. Do not block air inlet or outlet. Never drop or insert
any object into any openings. Do not place hands,
face or body directly over or near the outlet while
unit is in operation.
13. Do not use outdoors or for commercial purposes.
14. Do not use appliance for other than intended use.
Misuse can cause injuries.
15. Always place humidifier on a dry, stable, level
surface.
16. WARNING: Failure to clean device per the cleaning
instructions in the Cleaning Section may result in
overheating or fire. This humidifier requires daily
and weekly maintenance to operate appropriately.
Refer to daily and weekly cleaning procedures. Use
only cleaners and additives recommended by the
manufacturer. Never use gasoline, glass cleaner,
furniture polish, paint thinner, or other household
solvents to clean any part of the humidifier.
17. Never tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit. Use both hands
when carrying a full tank of water. Do not move unit
after it has been used until unit cools completely.
FEATURES - OPERATIONS
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
POLARIZED PLUG
This appliance has a polarized plug, (one blade is wider than the other). As a safety
feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician. Do not attempt to defeat this safety feature or modify
the plug in any way. If the plug fits loosely into the AC outlet or if the AC outlet feels warm
do not use that outlet.
you to see the tank in the dark. Press the Tank Light
Button ( ) to see unit and tank water level while in the
dark.
Cool/Warm Mist Control
Your humidifier can be selected to generate either cool
mist or warm mist by pressing the Cool/Warm Mist Control
Button
( )
. Each press of the button will switch between
cool and warm, and respective indicator will illuminate. You
can also turn the Mist Nozzle in multiple directions to
achieve your desired direction for mist output.
NOTE: the warm setting is not designed to be hot. It is just
above the standard ambient room conditions to prevent the
nasal passages from being too cool from the cool moisture.
Mist Output Setting
You may press the Mist Button to select from H/M/L which means
High/Medium/Low mist output levels.
WARNING: DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of
the water may activate the water tank’s release nozzle
and overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
Timer Mode
4, 8, 12 hour auto shut off. Feature will allow the unit to
run for the preset time and then shut off after the time
has lapsed or if it runs out of water.
Tank Refill Indicator
Once the tank is empty, the Refill indicator will illuminate,
the unit will stop working, all buttons will not function
until you refill the tank.
For refill, please unplug the unit and empty any residual
water from the base and the tank (follow the Daily
Maintenance Instructions). Then follow the Filling
Instructions to refill the tank and put back into the
humidifier to begin operation.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To benefit most from the humidifier and
avoid product misuse, follow all instructions carefully.
Please note that this is an electrical appliance and requires
attention when in use.
In addition, if you do not follow the recommended care
and maintenance guidelines, micro-organisms may grow
in the water within the water tank. You must routinely
follow the cleaning procedures that follow in order to
ensure proper, efficient operation of your humidifier.
Proper maintenance and cleaning is essential to the
continued performance of your unit and the avoidance of
algae or bacteria build-up.
This appliance has no user serviceable parts. Any servicing
beyond that described in the Cleaning Section should be
performed by an Authorized Service Representative only.
See warranty available online.
Daily Maintenance:
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the tank from the humidifier and place in
sink or tub.
3. Remove the tank cap and empty excess water from
tank.
5. Refill tank with cool tap water as instructed earlier in
the Filling Instructions. Do not overfill.
6. Follow Operating Instructions to turn on the humidifier.
NOTE: Before operation of the humidifier, ensure the
rubber valve is in place to cover the hole at the bottom of
the base.
Weekly Maintenance:
1. Repeat previous steps in Daily Maintenance.
2. Remove the blue demineralization cartridge from the
base. Pour 1 cup (8oz/236ml) of undiluted white
vinegar in the water inlet area. The vinegar will
automatically transfer to the transducer and float area.
Clean the base by partially filling the base with 1 cup
(8oz/236ml) of undiluted white vinegar. Leave this
solution in the base for 20 minutes, while cleaning all
the interior surfaces with the blue soft brush that is
nested on the bottom of the tank. Remove base scale
by wiping the base with a cloth dampened with
undiluted white vinegar after the soaking cycle is
complete, pour vinegar out (pour towards back left
corner of base as indicated by the arrow on the base.
Be careful not to get it in the fan housing.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
the party responsible for compliance could void the
user’s authority to operate the equipment.
HOW ULTRASONIC WORKS:
An ultrasonic transducer atomizes water, producing
refreshing visible cool or warm mist. The temperature of
warm mist is between 86 ˚F (30 °C) - 104 ˚F (40 °C).
NOTE: A humidity level below 20% can be unhealthy
and uncomfortable. The humidifier should be placed in a
normal temperature environment 41 ˚F (5 °C) - 104 ˚F
(40 °C), otherwise, the humidifier may be destroyed in
the cold environment. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched OFF and the unit is
disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4 inches (10 cm) away from the wall. DO NOT
place the humidifier on a finished floor or near
furniture, which can be damaged by too much moisture
or water. Place on a moisture resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the main housing.
2. Bring the tank to the sink, turn upside down and twist off
the tank cap by turning counter clockwise. Fill tank with
cool, fresh tap water. DO NOT fill with warm water as this
may cause leaking. Replace the cap on tank FIRMLY.
3. Place tank back into the humidifier housing. The tank
will immediately begin to empty into the base. There
will be "gurgling" sound and air bubbles appear in
the tank. It takes about 2-5 minutes for air bubbles
to disappear and the humidifier is then ready to
generate mist.
4. Plug the humidifier into a 120V electrical outlet.
OPERATING INSTRUCTIONS
Power On/Off
Press the Power Button
( )
to turn the humidifier on.
The humidifier will run at Medium setting and the Tank
Lignt will illuminate. Press the Power Button to manually
turn light off the humidifier at any setting.
Tank Light
Your humidifier is equipped with a Tank Light which allows
Figure 1
A
B
E
C
D
A. Carry Handle
B. Water Tank
C. Demineralization
Cartridge
D. Control Panel (see
Figure 2 for close-up)
E. Humidifier Base
F. Timer Button
G. Tank Light Button
H. Power Button
I. Cool/Warm Mist
Control Button
J. Mist Output Setting
Button
I
J
G
F
H
Figure 2
Control Panel (close-up)
HUL9500B_19EM1.indd 2 5/21/19 10:11
background
IMPORTANT SAFEGUARDS
FEATURES - OPERATIONS
18. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer, available
at your local retailer, to measure the humidity.
19. Never operate unit without water in the tank. Do not
pour water in any openings other than the water tank.
For warm mist models:
20. WARNING: Hot steam can cause serious burn
injuries. Keep away from steam while in operation,
especially children. Do not allow children access to
the appliance during operation.
21. Allow unit to cool before refilling water tank or
maintenance, as the heater bulb is hot.
22. Do not attempt to remove the water tank within 15
minutes after the humidifier is turned off and
unplugged. Serious injury may result.
SAVE THESE
INSTRUCTIONS
HOUSEHOLD USE ONLY
POWER CORD INSTRUCTIONS:
A short power-supply cord or detachable power-supply
cord is provided to reduce risks resulting from becoming
entangled in or tripping over a longer cord. Longer
detachable power-supply cords or extension cords are
available and may be used if care is exercised in their
use. If a long detachable power-supply cord or extension
cord is used on short-cord models:
a. The marked electrical rating of the detachable power-
supply cord or extension cord should be at least as
great as the electrical rating of the appliance;
b. When the product is of the grounded type, the extension
cord shall be a grounding type 3-wire cord; and
c. The longer cord should be arranged so that it will not
drape over the counter top or table top where it can
be pulled on by children or tripped over
unintentionally.
Do not pull, twist or otherwise abuse the power cord.
Do not wrap the power cord around the main body of the
appliance during or after use.
NOTICES
1. Do not allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wallpaper.
2. Keep unit away from surfaces that can be damaged
by water and/or heat (such as wood floors). Place
mat underneath the unit during use. Do not place
humidifier under overhanging surfaces.
3. Do not place the humidifier on a rug or carpet. The
heat sink underneath the humidifier might cause the
carpet to be discolored and may cause overheating of
the unit.
4. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
FCC STATEMENT
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
This product has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 18
of the FCC rules.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
The product generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that the interference will not occur in a
particular installation. If the product does cause harmful
interference to radio or television reception, which can be
determined by turning the product on or off, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the product and the
receiver.
Connect the product into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the
following:
1. Read all instructions before using the appliance.
2. To protect against electric shock, do not place or
immerse cord, plugs, or appliance in water or other
liquid. Do not plug in the cord with wet hands. Do
not overfill the water tank.
3. Plug the appliance directly into a 120VAC electrical
outlet.
4. This appliance is not intended for use by children or
by persons with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge.
Close supervision is necessary when any appliance is
used near children. Children should be supervised to
ensure that they do not play with the appliance.
Keep the appliance and its cord out of reach of
children.
5. Never place humidifier in an area where it is
accessible to children. Never use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. Keep the cord out of heavy traffic areas. To reduce
risk of fire, never put the cord under rugs or near
heat registers.
7. Do not operate any appliance with a damaged cord
or plug or after the appliance malfunctions, or has
been damaged in any manner. Do not attempt to
replace or splice a damaged cord. Return appliance
to the manufacturer (see warranty) for examination,
repair or adjustment.
8. Do not place on or near wet surfaces, or near heat
sources such as stoves, radiators, and heaters.
9. Place your humidifier on an inside wall near an
electrical outlet. The humidifier should be at least 4
inches (10 cm) away from the wall for best results.
10. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury.
11. Unplug from outlet when not in use, before putting
on or taking off parts and before cleaning. To
disconnect, turn any control to OFF, then unplug
power cord from outlet. Be sure to unplug the unit
by pulling on the plug and not the cord.
12. Do not block air inlet or outlet. Never drop or insert
any object into any openings. Do not place hands,
face or body directly over or near the outlet while
unit is in operation.
13. Do not use outdoors or for commercial purposes.
14. Do not use appliance for other than intended use.
Misuse can cause injuries.
15. Always place humidifier on a dry, stable, level
surface.
16. WARNING: Failure to clean device per the cleaning
instructions in the Cleaning Section may result in
overheating or fire. This humidifier requires daily
and weekly maintenance to operate appropriately.
Refer to daily and weekly cleaning procedures. Use
only cleaners and additives recommended by the
manufacturer. Never use gasoline, glass cleaner,
furniture polish, paint thinner, or other household
solvents to clean any part of the humidifier.
17. Never tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit. Use both hands
when carrying a full tank of water. Do not move unit
after it has been used until unit cools completely.
FEATURES - OPERATIONS
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
POLARIZED PLUG
This appliance has a polarized plug, (one blade is wider than the other). As a safety
feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician. Do not attempt to defeat this safety feature or modify
the plug in any way. If the plug fits loosely into the AC outlet or if the AC outlet feels warm
do not use that outlet.
you to see the tank in the dark. Press the Tank Light
Button ( ) to see unit and tank water level while in the
dark.
Cool/Warm Mist Control
Your humidifier can be selected to generate either cool
mist or warm mist by pressing the Cool/Warm Mist Control
Button
( )
. Each press of the button will switch between
cool and warm, and respective indicator will illuminate. You
can also turn the Mist Nozzle in multiple directions to
achieve your desired direction for mist output.
NOTE: the warm setting is not designed to be hot. It is just
above the standard ambient room conditions to prevent the
nasal passages from being too cool from the cool moisture.
Mist Output Setting
You may press the Mist Button to select from H/M/L which means
High/Medium/Low mist output levels.
WARNING: DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of
the water may activate the water tank’s release nozzle
and overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
Timer Mode
4, 8, 12 hour auto shut off. Feature will allow the unit to
run for the preset time and then shut off after the time
has lapsed or if it runs out of water.
Tank Refill Indicator
Once the tank is empty, the Refill indicator will illuminate,
the unit will stop working, all buttons will not function
until you refill the tank.
For refill, please unplug the unit and empty any residual
water from the base and the tank (follow the Daily
Maintenance Instructions). Then follow the Filling
Instructions to refill the tank and put back into the
humidifier to begin operation.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To benefit most from the humidifier and
avoid product misuse, follow all instructions carefully.
Please note that this is an electrical appliance and requires
attention when in use.
In addition, if you do not follow the recommended care
and maintenance guidelines, micro-organisms may grow
in the water within the water tank. You must routinely
follow the cleaning procedures that follow in order to
ensure proper, efficient operation of your humidifier.
Proper maintenance and cleaning is essential to the
continued performance of your unit and the avoidance of
algae or bacteria build-up.
This appliance has no user serviceable parts. Any servicing
beyond that described in the Cleaning Section should be
performed by an Authorized Service Representative only.
See warranty available online.
Daily Maintenance:
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the tank from the humidifier and place in
sink or tub.
3. Remove the tank cap and empty excess water from
tank.
5. Refill tank with cool tap water as instructed earlier in
the Filling Instructions. Do not overfill.
6. Follow Operating Instructions to turn on the humidifier.
NOTE: Before operation of the humidifier, ensure the
rubber valve is in place to cover the hole at the bottom of
the base.
Weekly Maintenance:
1. Repeat previous steps in Daily Maintenance.
2. Remove the blue demineralization cartridge from the
base. Pour 1 cup (8oz/236ml) of undiluted white
vinegar in the water inlet area. The vinegar will
automatically transfer to the transducer and float area.
Clean the base by partially filling the base with 1 cup
(8oz/236ml) of undiluted white vinegar. Leave this
solution in the base for 20 minutes, while cleaning all
the interior surfaces with the blue soft brush that is
nested on the bottom of the tank. Remove base scale
by wiping the base with a cloth dampened with
undiluted white vinegar after the soaking cycle is
complete, pour vinegar out (pour towards back left
corner of base as indicated by the arrow on the base.
Be careful not to get it in the fan housing.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
the party responsible for compliance could void the
user’s authority to operate the equipment.
HOW ULTRASONIC WORKS:
An ultrasonic transducer atomizes water, producing
refreshing visible cool or warm mist. The temperature of
warm mist is between 86 ˚F (30 °C) - 104 ˚F (40 °C).
NOTE: A humidity level below 20% can be unhealthy
and uncomfortable. The humidifier should be placed in a
normal temperature environment 41 ˚F (5 °C) - 104 ˚F
(40 °C), otherwise, the humidifier may be destroyed in
the cold environment. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched OFF and the unit is
disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4 inches (10 cm) away from the wall. DO NOT
place the humidifier on a finished floor or near
furniture, which can be damaged by too much moisture
or water. Place on a moisture resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the main housing.
2. Bring the tank to the sink, turn upside down and twist off
the tank cap by turning counter clockwise. Fill tank with
cool, fresh tap water. DO NOT fill with warm water as this
may cause leaking. Replace the cap on tank FIRMLY.
3. Place tank back into the humidifier housing. The tank
will immediately begin to empty into the base. There
will be "gurgling" sound and air bubbles appear in
the tank. It takes about 2-5 minutes for air bubbles
to disappear and the humidifier is then ready to
generate mist.
4. Plug the humidifier into a 120V electrical outlet.
OPERATING INSTRUCTIONS
Power On/Off
Press the Power Button
( )
to turn the humidifier on.
The humidifier will run at Medium setting and the Tank
Lignt will illuminate. Press the Power Button to manually
turn light off the humidifier at any setting.
Tank Light
Your humidifier is equipped with a Tank Light which allows
Figure 1
A
B
E
C
D
A. Carry Handle
B. Water Tank
C. Demineralization
Cartridge
D. Control Panel (see
Figure 2 for close-up)
E. Humidifier Base
F. Timer Button
G. Tank Light Button
H. Power Button
I. Cool/Warm Mist
Control Button
J. Mist Output Setting
Button
I
J
G
F
H
Figure 2
Control Panel (close-up)
HUL9500B_19EM1.indd 2 5/21/19 10:11
background
IMPORTANT SAFEGUARDS
FEATURES - OPERATIONS
18. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer, available
at your local retailer, to measure the humidity.
19. Never operate unit without water in the tank. Do not
pour water in any openings other than the water tank.
For warm mist models:
20. WARNING: Hot steam can cause serious burn
injuries. Keep away from steam while in operation,
especially children. Do not allow children access to
the appliance during operation.
21. Allow unit to cool before refilling water tank or
maintenance, as the heater bulb is hot.
22. Do not attempt to remove the water tank within 15
minutes after the humidifier is turned off and
unplugged. Serious injury may result.
SAVE THESE
INSTRUCTIONS
HOUSEHOLD USE ONLY
POWER CORD INSTRUCTIONS:
A short power-supply cord or detachable power-supply
cord is provided to reduce risks resulting from becoming
entangled in or tripping over a longer cord. Longer
detachable power-supply cords or extension cords are
available and may be used if care is exercised in their
use. If a long detachable power-supply cord or extension
cord is used on short-cord models:
a. The marked electrical rating of the detachable power-
supply cord or extension cord should be at least as
great as the electrical rating of the appliance;
b. When the product is of the grounded type, the extension
cord shall be a grounding type 3-wire cord; and
c. The longer cord should be arranged so that it will not
drape over the counter top or table top where it can
be pulled on by children or tripped over
unintentionally.
Do not pull, twist or otherwise abuse the power cord.
Do not wrap the power cord around the main body of the
appliance during or after use.
NOTICES
1. Do not allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wallpaper.
2. Keep unit away from surfaces that can be damaged
by water and/or heat (such as wood floors). Place
mat underneath the unit during use. Do not place
humidifier under overhanging surfaces.
3. Do not place the humidifier on a rug or carpet. The
heat sink underneath the humidifier might cause the
carpet to be discolored and may cause overheating of
the unit.
4. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
FCC STATEMENT
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
This product has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 18
of the FCC rules.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
The product generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that the interference will not occur in a
particular installation. If the product does cause harmful
interference to radio or television reception, which can be
determined by turning the product on or off, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the product and the
receiver.
Connect the product into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the
following:
1. Read all instructions before using the appliance.
2. To protect against electric shock, do not place or
immerse cord, plugs, or appliance in water or other
liquid. Do not plug in the cord with wet hands. Do
not overfill the water tank.
3. Plug the appliance directly into a 120VAC electrical
outlet.
4. This appliance is not intended for use by children or
by persons with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge.
Close supervision is necessary when any appliance is
used near children. Children should be supervised to
ensure that they do not play with the appliance.
Keep the appliance and its cord out of reach of
children.
5. Never place humidifier in an area where it is
accessible to children. Never use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. Keep the cord out of heavy traffic areas. To reduce
risk of fire, never put the cord under rugs or near
heat registers.
7. Do not operate any appliance with a damaged cord
or plug or after the appliance malfunctions, or has
been damaged in any manner. Do not attempt to
replace or splice a damaged cord. Return appliance
to the manufacturer (see warranty) for examination,
repair or adjustment.
8. Do not place on or near wet surfaces, or near heat
sources such as stoves, radiators, and heaters.
9. Place your humidifier on an inside wall near an
electrical outlet. The humidifier should be at least 4
inches (10 cm) away from the wall for best results.
10. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury.
11. Unplug from outlet when not in use, before putting
on or taking off parts and before cleaning. To
disconnect, turn any control to OFF, then unplug
power cord from outlet. Be sure to unplug the unit
by pulling on the plug and not the cord.
12. Do not block air inlet or outlet. Never drop or insert
any object into any openings. Do not place hands,
face or body directly over or near the outlet while
unit is in operation.
13. Do not use outdoors or for commercial purposes.
14. Do not use appliance for other than intended use.
Misuse can cause injuries.
15. Always place humidifier on a dry, stable, level
surface.
16. WARNING: Failure to clean device per the cleaning
instructions in the Cleaning Section may result in
overheating or fire. This humidifier requires daily
and weekly maintenance to operate appropriately.
Refer to daily and weekly cleaning procedures. Use
only cleaners and additives recommended by the
manufacturer. Never use gasoline, glass cleaner,
furniture polish, paint thinner, or other household
solvents to clean any part of the humidifier.
17. Never tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit. Use both hands
when carrying a full tank of water. Do not move unit
after it has been used until unit cools completely.
FEATURES - OPERATIONS
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
POLARIZED PLUG
This appliance has a polarized plug, (one blade is wider than the other). As a safety
feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician. Do not attempt to defeat this safety feature or modify
the plug in any way. If the plug fits loosely into the AC outlet or if the AC outlet feels warm
do not use that outlet.
you to see the tank in the dark. Press the Tank Light
Button ( ) to see unit and tank water level while in the
dark.
Cool/Warm Mist Control
Your humidifier can be selected to generate either cool
mist or warm mist by pressing the Cool/Warm Mist Control
Button
( )
. Each press of the button will switch between
cool and warm, and respective indicator will illuminate. You
can also turn the Mist Nozzle in multiple directions to
achieve your desired direction for mist output.
NOTE: the warm setting is not designed to be hot. It is just
above the standard ambient room conditions to prevent the
nasal passages from being too cool from the cool moisture.
Mist Output Setting
You may press the Mist Button to select from H/M/L which means
High/Medium/Low mist output levels.
WARNING: DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of
the water may activate the water tank’s release nozzle
and overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
Timer Mode
4, 8, 12 hour auto shut off. Feature will allow the unit to
run for the preset time and then shut off after the time
has lapsed or if it runs out of water.
Tank Refill Indicator
Once the tank is empty, the Refill indicator will illuminate,
the unit will stop working, all buttons will not function
until you refill the tank.
For refill, please unplug the unit and empty any residual
water from the base and the tank (follow the Daily
Maintenance Instructions). Then follow the Filling
Instructions to refill the tank and put back into the
humidifier to begin operation.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To benefit most from the humidifier and
avoid product misuse, follow all instructions carefully.
Please note that this is an electrical appliance and requires
attention when in use.
In addition, if you do not follow the recommended care
and maintenance guidelines, micro-organisms may grow
in the water within the water tank. You must routinely
follow the cleaning procedures that follow in order to
ensure proper, efficient operation of your humidifier.
Proper maintenance and cleaning is essential to the
continued performance of your unit and the avoidance of
algae or bacteria build-up.
This appliance has no user serviceable parts. Any servicing
beyond that described in the Cleaning Section should be
performed by an Authorized Service Representative only.
See warranty available online.
Daily Maintenance:
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the tank from the humidifier and place in
sink or tub.
3. Remove the tank cap and empty excess water from
tank.
5. Refill tank with cool tap water as instructed earlier in
the Filling Instructions. Do not overfill.
6. Follow Operating Instructions to turn on the humidifier.
NOTE: Before operation of the humidifier, ensure the
rubber valve is in place to cover the hole at the bottom of
the base.
Weekly Maintenance:
1. Repeat previous steps in Daily Maintenance.
2. Remove the blue demineralization cartridge from the
base. Pour 1 cup (8oz/236ml) of undiluted white
vinegar in the water inlet area. The vinegar will
automatically transfer to the transducer and float area.
Clean the base by partially filling the base with 1 cup
(8oz/236ml) of undiluted white vinegar. Leave this
solution in the base for 20 minutes, while cleaning all
the interior surfaces with the blue soft brush that is
nested on the bottom of the tank. Remove base scale
by wiping the base with a cloth dampened with
undiluted white vinegar after the soaking cycle is
complete, pour vinegar out (pour towards back left
corner of base as indicated by the arrow on the base.
Be careful not to get it in the fan housing.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
the party responsible for compliance could void the
user’s authority to operate the equipment.
HOW ULTRASONIC WORKS:
An ultrasonic transducer atomizes water, producing
refreshing visible cool or warm mist. The temperature of
warm mist is between 86 ˚F (30 °C) - 104 ˚F (40 °C).
NOTE: A humidity level below 20% can be unhealthy
and uncomfortable. The humidifier should be placed in a
normal temperature environment 41 ˚F (5 °C) - 104 ˚F
(40 °C), otherwise, the humidifier may be destroyed in
the cold environment. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched OFF and the unit is
disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4 inches (10 cm) away from the wall. DO NOT
place the humidifier on a finished floor or near
furniture, which can be damaged by too much moisture
or water. Place on a moisture resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the main housing.
2. Bring the tank to the sink, turn upside down and twist off
the tank cap by turning counter clockwise. Fill tank with
cool, fresh tap water. DO NOT fill with warm water as this
may cause leaking. Replace the cap on tank FIRMLY.
3. Place tank back into the humidifier housing. The tank
will immediately begin to empty into the base. There
will be "gurgling" sound and air bubbles appear in
the tank. It takes about 2-5 minutes for air bubbles
to disappear and the humidifier is then ready to
generate mist.
4. Plug the humidifier into a 120V electrical outlet.
OPERATING INSTRUCTIONS
Power On/Off
Press the Power Button
( )
to turn the humidifier on.
The humidifier will run at Medium setting and the Tank
Lignt will illuminate. Press the Power Button to manually
turn light off the humidifier at any setting.
Tank Light
Your humidifier is equipped with a Tank Light which allows
Figure 1
A
B
E
C
D
A. Carry Handle
B. Water Tank
C. Demineralization
Cartridge
D. Control Panel (see
Figure 2 for close-up)
E. Humidifier Base
F. Timer Button
G. Tank Light Button
H. Power Button
I. Cool/Warm Mist
Control Button
J. Mist Output Setting
Button
I
J
G
F
H
Figure 2
Control Panel (close-up)
HUL9500B_19EM1.indd 2 5/21/19 10:11
background
IMPORTANT SAFEGUARDS
FEATURES - OPERATIONS
18. Do not use humidifier in an area where humidity
level is in excess of 50%. Use a hygrometer, available
at your local retailer, to measure the humidity.
19. Never operate unit without water in the tank. Do not
pour water in any openings other than the water tank.
For warm mist models:
20. WARNING: Hot steam can cause serious burn
injuries. Keep away from steam while in operation,
especially children. Do not allow children access to
the appliance during operation.
21. Allow unit to cool before refilling water tank or
maintenance, as the heater bulb is hot.
22. Do not attempt to remove the water tank within 15
minutes after the humidifier is turned off and
unplugged. Serious injury may result.
SAVE THESE
INSTRUCTIONS
HOUSEHOLD USE ONLY
POWER CORD INSTRUCTIONS:
A short power-supply cord or detachable power-supply
cord is provided to reduce risks resulting from becoming
entangled in or tripping over a longer cord. Longer
detachable power-supply cords or extension cords are
available and may be used if care is exercised in their
use. If a long detachable power-supply cord or extension
cord is used on short-cord models:
a. The marked electrical rating of the detachable power-
supply cord or extension cord should be at least as
great as the electrical rating of the appliance;
b. When the product is of the grounded type, the extension
cord shall be a grounding type 3-wire cord; and
c. The longer cord should be arranged so that it will not
drape over the counter top or table top where it can
be pulled on by children or tripped over
unintentionally.
Do not pull, twist or otherwise abuse the power cord.
Do not wrap the power cord around the main body of the
appliance during or after use.
NOTICES
1. Do not allow the Moisture Outlet to directly face the
wall. Moisture could cause damage, particularly to
wallpaper.
2. Keep unit away from surfaces that can be damaged
by water and/or heat (such as wood floors). Place
mat underneath the unit during use. Do not place
humidifier under overhanging surfaces.
3. Do not place the humidifier on a rug or carpet. The
heat sink underneath the humidifier might cause the
carpet to be discolored and may cause overheating of
the unit.
4. Excessive humidity in a room can cause water
condensation on windows and some furniture. If this
happens, turn the humidifier OFF.
FCC STATEMENT
Potential for Radio/Television interference
This device complies with Part 18 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
This product has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 18
of the FCC rules.
These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
The product generates, uses, and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that the interference will not occur in a
particular installation. If the product does cause harmful
interference to radio or television reception, which can be
determined by turning the product on or off, the user is
encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the product and the
receiver.
Connect the product into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV
technician for help.
Changes or modifications not expressly approved by
When using electrical appliances, basic safety precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the
following:
1. Read all instructions before using the appliance.
2. To protect against electric shock, do not place or
immerse cord, plugs, or appliance in water or other
liquid. Do not plug in the cord with wet hands. Do
not overfill the water tank.
3. Plug the appliance directly into a 120VAC electrical
outlet.
4. This appliance is not intended for use by children or
by persons with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge.
Close supervision is necessary when any appliance is
used near children. Children should be supervised to
ensure that they do not play with the appliance.
Keep the appliance and its cord out of reach of
children.
5. Never place humidifier in an area where it is
accessible to children. Never use humidifier in a
closed room, particularly where a child may be
sleeping, resting, or playing (a closed room may
result in excessive humidity).
6. Keep the cord out of heavy traffic areas. To reduce
risk of fire, never put the cord under rugs or near
heat registers.
7. Do not operate any appliance with a damaged cord
or plug or after the appliance malfunctions, or has
been damaged in any manner. Do not attempt to
replace or splice a damaged cord. Return appliance
to the manufacturer (see warranty) for examination,
repair or adjustment.
8. Do not place on or near wet surfaces, or near heat
sources such as stoves, radiators, and heaters.
9. Place your humidifier on an inside wall near an
electrical outlet. The humidifier should be at least 4
inches (10 cm) away from the wall for best results.
10. WARNING: Do not attempt to refill humidifier
without first unplugging the unit from its electrical
outlet. Failure to heed this warning may cause
personal injury.
11. Unplug from outlet when not in use, before putting
on or taking off parts and before cleaning. To
disconnect, turn any control to OFF, then unplug
power cord from outlet. Be sure to unplug the unit
by pulling on the plug and not the cord.
12. Do not block air inlet or outlet. Never drop or insert
any object into any openings. Do not place hands,
face or body directly over or near the outlet while
unit is in operation.
13. Do not use outdoors or for commercial purposes.
14. Do not use appliance for other than intended use.
Misuse can cause injuries.
15. Always place humidifier on a dry, stable, level
surface.
16. WARNING: Failure to clean device per the cleaning
instructions in the Cleaning Section may result in
overheating or fire. This humidifier requires daily
and weekly maintenance to operate appropriately.
Refer to daily and weekly cleaning procedures. Use
only cleaners and additives recommended by the
manufacturer. Never use gasoline, glass cleaner,
furniture polish, paint thinner, or other household
solvents to clean any part of the humidifier.
17. Never tilt, move, or attempt to empty unit while it is
operating. Shut off and unplug before removing the
water tank and moving the unit. Use both hands
when carrying a full tank of water. Do not move unit
after it has been used until unit cools completely.
FEATURES - OPERATIONS
FEATURES - OPERATIONS
CLEANING / MAINTENANCE
POLARIZED PLUG
This appliance has a polarized plug, (one blade is wider than the other). As a safety
feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet
only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician. Do not attempt to defeat this safety feature or modify
the plug in any way. If the plug fits loosely into the AC outlet or if the AC outlet feels warm
do not use that outlet.
you to see the tank in the dark. Press the Tank Light
Button ( ) to see unit and tank water level while in the
dark.
Cool/Warm Mist Control
Your humidifier can be selected to generate either cool
mist or warm mist by pressing the Cool/Warm Mist Control
Button
( )
. Each press of the button will switch between
cool and warm, and respective indicator will illuminate. You
can also turn the Mist Nozzle in multiple directions to
achieve your desired direction for mist output.
NOTE: the warm setting is not designed to be hot. It is just
above the standard ambient room conditions to prevent the
nasal passages from being too cool from the cool moisture.
Mist Output Setting
You may press the Mist Button to select from H/M/L which means
High/Medium/Low mist output levels.
WARNING: DO NOT move the humidifier with water in
the tank or the humidifier base. The moving action of
the water may activate the water tank’s release nozzle
and overfill the humidifier base. This may cause the
humidifier to function intermittently, or stop emitting
mist. Should this occurs, simply remove the excess water
from the humidifier base.
Timer Mode
4, 8, 12 hour auto shut off. Feature will allow the unit to
run for the preset time and then shut off after the time
has lapsed or if it runs out of water.
Tank Refill Indicator
Once the tank is empty, the Refill indicator will illuminate,
the unit will stop working, all buttons will not function
until you refill the tank.
For refill, please unplug the unit and empty any residual
water from the base and the tank (follow the Daily
Maintenance Instructions). Then follow the Filling
Instructions to refill the tank and put back into the
humidifier to begin operation.
CLEANING AND MAINTENANCE
INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry,
heated indoor air. To benefit most from the humidifier and
avoid product misuse, follow all instructions carefully.
Please note that this is an electrical appliance and requires
attention when in use.
In addition, if you do not follow the recommended care
and maintenance guidelines, micro-organisms may grow
in the water within the water tank. You must routinely
follow the cleaning procedures that follow in order to
ensure proper, efficient operation of your humidifier.
Proper maintenance and cleaning is essential to the
continued performance of your unit and the avoidance of
algae or bacteria build-up.
This appliance has no user serviceable parts. Any servicing
beyond that described in the Cleaning Section should be
performed by an Authorized Service Representative only.
See warranty available online.
Daily Maintenance:
1. Be sure the unit is OFF and is disconnected from the
electrical outlet.
2. Remove the tank from the humidifier and place in
sink or tub.
3. Remove the tank cap and empty excess water from
tank.
5. Refill tank with cool tap water as instructed earlier in
the Filling Instructions. Do not overfill.
6. Follow Operating Instructions to turn on the humidifier.
NOTE: Before operation of the humidifier, ensure the
rubber valve is in place to cover the hole at the bottom of
the base.
Weekly Maintenance:
1. Repeat previous steps in Daily Maintenance.
2. Remove the blue demineralization cartridge from the
base. Pour 1 cup (8oz/236ml) of undiluted white
vinegar in the water inlet area. The vinegar will
automatically transfer to the transducer and float area.
Clean the base by partially filling the base with 1 cup
(8oz/236ml) of undiluted white vinegar. Leave this
solution in the base for 20 minutes, while cleaning all
the interior surfaces with the blue soft brush that is
nested on the bottom of the tank. Remove base scale
by wiping the base with a cloth dampened with
undiluted white vinegar after the soaking cycle is
complete, pour vinegar out (pour towards back left
corner of base as indicated by the arrow on the base.
Be careful not to get it in the fan housing.
3. Rinse with clean warm water to remove the cleaning
solution before disinfecting the tank.
the party responsible for compliance could void the
user’s authority to operate the equipment.
HOW ULTRASONIC WORKS:
An ultrasonic transducer atomizes water, producing
refreshing visible cool or warm mist. The temperature of
warm mist is between 86 ˚F (30 °C) - 104 ˚F (40 °C).
NOTE: A humidity level below 20% can be unhealthy
and uncomfortable. The humidifier should be placed in a
normal temperature environment 41 ˚F (5 °C) - 104 ˚F
(40 °C), otherwise, the humidifier may be destroyed in
the cold environment. The recommended humidity level is
between 40%-50%.
PRE-OPERATING INSTRUCTIONS
1. Be sure the humidifier is switched OFF and the unit is
disconnected from the electrical outlet.
2. Select a location for your humidifier, on a flat surface,
about 4 inches (10 cm) away from the wall. DO NOT
place the humidifier on a finished floor or near
furniture, which can be damaged by too much moisture
or water. Place on a moisture resistant surface.
FILLING THE WATER TANK
1. Remove the tank from the main housing.
2. Bring the tank to the sink, turn upside down and twist off
the tank cap by turning counter clockwise. Fill tank with
cool, fresh tap water. DO NOT fill with warm water as this
may cause leaking. Replace the cap on tank FIRMLY.
3. Place tank back into the humidifier housing. The tank
will immediately begin to empty into the base. There
will be "gurgling" sound and air bubbles appear in
the tank. It takes about 2-5 minutes for air bubbles
to disappear and the humidifier is then ready to
generate mist.
4. Plug the humidifier into a 120V electrical outlet.
OPERATING INSTRUCTIONS
Power On/Off
Press the Power Button
( )
to turn the humidifier on.
The humidifier will run at Medium setting and the Tank
Lignt will illuminate. Press the Power Button to manually
turn light off the humidifier at any setting.
Tank Light
Your humidifier is equipped with a Tank Light which allows
Figure 1
A
B
E
C
D
A. Carry Handle
B. Water Tank
C. Demineralization
Cartridge
D. Control Panel (see
Figure 2 for close-up)
E. Humidifier Base
F. Timer Button
G. Tank Light Button
H. Power Button
I. Cool/Warm Mist
Control Button
J. Mist Output Setting
Button
I
J
G
F
H
Figure 2
Control Panel (close-up)
HUL9500B_19EM1.indd 2 5/21/19 10:11
background
WARRANTY INFORMATION
3 YEAR LIMITED WARRANTY
Sunbeam Products, Inc. (“Sunbeam”) or if in Canada, Newell Brands Canada ULC (“NBC”) warrants that for a period of one
(3) years from the date of initial retail purchase, this product will be free from defects in material and workmanship, when
used in accordance with the instructions provided.
Sunbeam (or NBC), at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period.
Replacement will be made with a new or remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT attempt
to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep
the original sales receipt. Proof of purchase is required to obtain warranty performance. Sunbeam (or NBC) dealers, service
centers, or retail stores selling Sunbeam (or NBC) products do not have the right to alter, modify or any way change the
terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of
the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration
by anyone other than Sunbeam (or NBC) or an authorized Sunbeam (or NBC) service center. Further, the warranty does not
cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on Sunbeam’s (or NBC’s) Liability?
Sunbeam (or NBC) shall not be liable for any incidental or consequential damages caused by the breach of any express, implied
or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or condition of
merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Sunbeam (or
NBC) disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise. Sunbeam (or NBC)
shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product
including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract, fundamental or
otherwise, or for any claim brought against purchaser by any other party. Some provinces, states or jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights that vary from province to province, state to state or jurisdiction to jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In Canada
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. located in Boca Raton, Florida 33431. In Canada, this warranty
is offered by Newell Brands Canada ULC, located at 20B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any other
problem or claim in connection with this product, please write our Consumer Service Department.
PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
©2019 Sunbeam Products, Inc. All rights reserved.
TROUBLESHOOTING
STORAGE INSTRUCTIONS
FREQUENTLY ASKED QUESTIONS
TROUBLESHOOTING
Trouble Probable Cause Solution
Water Leaks from
Tank.
Tank/cap gasket is missing.
Unit tilted or not leveled.
Cap not tight enough.
Tank water is Hot.
Remove tank cap and replace or reposition
gasket.
Place unit it on a flat or leveled surface.
Tighten the cap.
Fill with cool water only.
Crack in Tank.
Hot water will cause tank to pressurize.
Tanks will crack if hit or dropped.
Fill with cool water only.
Handle tank with care. If there is crack on
tank, replace with a new tank.
Film on Tank.
Mineral deposits.
Clean/disinfect tank as instructed in weekly
cleaning instructions.
Mist output
minimal to none.
Scale build up on transducer. Replace the dimineralization cartridge by
following the maintenence instructions.
Reduced or no mist.
Out of water.
Improper Maintenance.
Demineralization cartridge not seated
properly.
Using low setting.
Fill tank.
Increase setting to High.
Properly seat the demineralization cartridge and
reseat tank.
Follow cleaning and maintenance instructions.
Appearance of
minerals or white
dust.
The demineralization cartridge is
assembled upside down and the tank
will not sit flush. This prevents the tank
plunger value from being activated to
all water to flow.
Use distilled water in your humidifier. This will
help reduce the precipitation of minerals or white
dust.
In addition, use a demineralization cartridge to
help reduce mineral build-up and “white-dust”
caused by hard water.
Tank does not fit
properly on the
base.
The demineralization cartridge is not
seated correctly in the base.
Confirm the proper placement of the
demineralization cartridge. The cartridge is
marked with "THIS SIDE UP".
FREQUENTLY ASKED QUESTIONS
Question Answer
What are the
variables that affect
run time?
The estimated run time for this humidifier is based on average room conditions. The actual run time
of your humidifier is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room where the humidifier
is placed.
Home furnishings in the room where the humidifier is placed.
How do I remove
film on water tank?
Vinegar and water soak will remove it within 20 mins.
How can I extend
the run time?
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit will turn on and off,
which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into the base until it stops
bubbling, then refill the tank full again. This ensures maximum water capacity and will extend
run time.
If you have any questions regarding your product or would like to learn more about other Holmes
®
products, please visit
our website at www.holmesproducts.com. For inquiries regarding recycling and proper disposal of this product, please
contact your local waste management facility.
199410 HUL9500B_19EM1 Printed In China
GCDS-HOL635678-JC
4. To rinse, pour 1 cup of cool tap water in the air inlet
area. Allow to reach transducer area. Pour out water.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon (0.25oz/7.4ml) of chlorine bleach.
2. Return tank to base. Allow to set for 20 minutes. Use
clean water in tank to flush system. Do not allow
water to get in the fan housing.
3. Carefully empty the tank after 20 minutes, and rinse
with warm water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
4. Discard bleach water in the base. pour towards the
left corner of base.
5. To clean the humidifier base, pour out all access
water. Rinse thoroughly to remove any sediment to
dirt. Wipe clean and dry with a clean cloth or paper
towel. Do not use metal cleaning utensils of abrasive
cleansers.
NOTE: Do not scrape the transducer with any other object
other than the brush provided. Damage could occur and
cause malfunction.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period
of time:
1. Clean, rinse and thoroughly dry the humidifier as
directed in weekly maintenance. DO NOT leave any
water in the unit when storing. Leaving water in the
unit may render the unit inoperable for the following
season.
2. Place the humidifier in the original carton and store
in a cool, dry place.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of
the following:
Visit your local retailer
Go to
www.holmesproducts.com
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Owner’s Guide
HUL9500B
Warm or Cool Ultrasonic
Humidifier
HUL9500B_19EM1.indd 1 5/21/19 10:10
background
WARRANTY INFORMATION
3 YEAR LIMITED WARRANTY
Sunbeam Products, Inc. (“Sunbeam”) or if in Canada, Newell Brands Canada ULC (“NBC”) warrants that for a period of one
(3) years from the date of initial retail purchase, this product will be free from defects in material and workmanship, when
used in accordance with the instructions provided.
Sunbeam (or NBC), at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period.
Replacement will be made with a new or remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT attempt
to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep
the original sales receipt. Proof of purchase is required to obtain warranty performance. Sunbeam (or NBC) dealers, service
centers, or retail stores selling Sunbeam (or NBC) products do not have the right to alter, modify or any way change the
terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of
the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration
by anyone other than Sunbeam (or NBC) or an authorized Sunbeam (or NBC) service center. Further, the warranty does not
cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on Sunbeam’s (or NBC’s) Liability?
Sunbeam (or NBC) shall not be liable for any incidental or consequential damages caused by the breach of any express, implied
or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or condition of
merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Sunbeam (or
NBC) disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise. Sunbeam (or NBC)
shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product
including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract, fundamental or
otherwise, or for any claim brought against purchaser by any other party. Some provinces, states or jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights that vary from province to province, state to state or jurisdiction to jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In Canada
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. located in Boca Raton, Florida 33431. In Canada, this warranty
is offered by Newell Brands Canada ULC, located at 20B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any other
problem or claim in connection with this product, please write our Consumer Service Department.
PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
©2019 Sunbeam Products, Inc. All rights reserved.
TROUBLESHOOTING
STORAGE INSTRUCTIONS
FREQUENTLY ASKED QUESTIONS
TROUBLESHOOTING
Trouble Probable Cause Solution
Water Leaks from
Tank.
Tank/cap gasket is missing.
Unit tilted or not leveled.
Cap not tight enough.
Tank water is Hot.
Remove tank cap and replace or reposition
gasket.
Place unit it on a flat or leveled surface.
Tighten the cap.
Fill with cool water only.
Crack in Tank.
Hot water will cause tank to pressurize.
Tanks will crack if hit or dropped.
Fill with cool water only.
Handle tank with care. If there is crack on
tank, replace with a new tank.
Film on Tank.
Mineral deposits.
Clean/disinfect tank as instructed in weekly
cleaning instructions.
Mist output
minimal to none.
Scale build up on transducer. Replace the dimineralization cartridge by
following the maintenence instructions.
Reduced or no mist.
Out of water.
Improper Maintenance.
Demineralization cartridge not seated
properly.
Using low setting.
Fill tank.
Increase setting to High.
Properly seat the demineralization cartridge and
reseat tank.
Follow cleaning and maintenance instructions.
Appearance of
minerals or white
dust.
The demineralization cartridge is
assembled upside down and the tank
will not sit flush. This prevents the tank
plunger value from being activated to
all water to flow.
Use distilled water in your humidifier. This will
help reduce the precipitation of minerals or white
dust.
In addition, use a demineralization cartridge to
help reduce mineral build-up and “white-dust”
caused by hard water.
Tank does not fit
properly on the
base.
The demineralization cartridge is not
seated correctly in the base.
Confirm the proper placement of the
demineralization cartridge. The cartridge is
marked with "THIS SIDE UP".
FREQUENTLY ASKED QUESTIONS
Question Answer
What are the
variables that affect
run time?
The estimated run time for this humidifier is based on average room conditions. The actual run time
of your humidifier is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room where the humidifier
is placed.
Home furnishings in the room where the humidifier is placed.
How do I remove
film on water tank?
Vinegar and water soak will remove it within 20 mins.
How can I extend
the run time?
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit will turn on and off,
which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into the base until it stops
bubbling, then refill the tank full again. This ensures maximum water capacity and will extend
run time.
If you have any questions regarding your product or would like to learn more about other Holmes
®
products, please visit
our website at www.holmesproducts.com. For inquiries regarding recycling and proper disposal of this product, please
contact your local waste management facility.
199410 HUL9500B_19EM1 Printed In China
GCDS-HOL635678-JC
4. To rinse, pour 1 cup of cool tap water in the air inlet
area. Allow to reach transducer area. Pour out water.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon (0.25oz/7.4ml) of chlorine bleach.
2. Return tank to base. Allow to set for 20 minutes. Use
clean water in tank to flush system. Do not allow
water to get in the fan housing.
3. Carefully empty the tank after 20 minutes, and rinse
with warm water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
4. Discard bleach water in the base. pour towards the
left corner of base.
5. To clean the humidifier base, pour out all access
water. Rinse thoroughly to remove any sediment to
dirt. Wipe clean and dry with a clean cloth or paper
towel. Do not use metal cleaning utensils of abrasive
cleansers.
NOTE: Do not scrape the transducer with any other object
other than the brush provided. Damage could occur and
cause malfunction.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period
of time:
1. Clean, rinse and thoroughly dry the humidifier as
directed in weekly maintenance. DO NOT leave any
water in the unit when storing. Leaving water in the
unit may render the unit inoperable for the following
season.
2. Place the humidifier in the original carton and store
in a cool, dry place.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of
the following:
Visit your local retailer
Go to
www.holmesproducts.com
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Owner’s Guide
HUL9500B
Warm or Cool Ultrasonic
Humidifier
HUL9500B_19EM1.indd 1 5/21/19 10:10
background
WARRANTY INFORMATION
3 YEAR LIMITED WARRANTY
Sunbeam Products, Inc. (“Sunbeam”) or if in Canada, Newell Brands Canada ULC (“NBC”) warrants that for a period of one
(3) years from the date of initial retail purchase, this product will be free from defects in material and workmanship, when
used in accordance with the instructions provided.
Sunbeam (or NBC), at its option, will repair or replace this product or any component of the product found to be defective
during the warranty period.
Replacement will be made with a new or remanufactured product or component. If the product is no longer available,
replacement may be made with a similar product of equal or greater value. This is your exclusive warranty. Do NOT attempt
to repair or adjust any electrical or mechanical functions on this product. Doing so will void this warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep
the original sales receipt. Proof of purchase is required to obtain warranty performance. Sunbeam (or NBC) dealers, service
centers, or retail stores selling Sunbeam (or NBC) products do not have the right to alter, modify or any way change the
terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of
the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration
by anyone other than Sunbeam (or NBC) or an authorized Sunbeam (or NBC) service center. Further, the warranty does not
cover: Acts of God, such as fire, flood, hurricanes and tornadoes.
What are the limits on Sunbeam’s (or NBC’s) Liability?
Sunbeam (or NBC) shall not be liable for any incidental or consequential damages caused by the breach of any express, implied
or statutory warranty or condition. Except to the extent prohibited by applicable law, any implied warranty or condition of
merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Sunbeam (or
NBC) disclaims all other warranties, conditions or representations, express, implied, statutory or otherwise. Sunbeam (or NBC)
shall not be liable for any damages of any kind resulting from the purchase, use or misuse of, or inability to use the product
including incidental, special, consequential or similar damages or loss of profits, or for any breach of contract, fundamental or
otherwise, or for any claim brought against purchaser by any other party. Some provinces, states or jurisdictions do not allow
the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights that vary from province to province, state to state or jurisdiction to jurisdiction.
How to Obtain Warranty Service
In the U.S.A.
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In Canada
If you have any questions regarding this warranty or would like to obtain warranty service, please visit our website
at www.holmesproducts.com.
In the U.S.A., this warranty is offered by Sunbeam Products, Inc. located in Boca Raton, Florida 33431. In Canada, this warranty
is offered by Newell Brands Canada ULC, located at 20B Hereford Street, Brampton, Ontario L6Y 0M1. If you have any other
problem or claim in connection with this product, please write our Consumer Service Department.
PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE.
©2019 Sunbeam Products, Inc. All rights reserved.
TROUBLESHOOTING
STORAGE INSTRUCTIONS
FREQUENTLY ASKED QUESTIONS
TROUBLESHOOTING
Trouble Probable Cause Solution
Water Leaks from
Tank.
Tank/cap gasket is missing.
Unit tilted or not leveled.
Cap not tight enough.
Tank water is Hot.
Remove tank cap and replace or reposition
gasket.
Place unit it on a flat or leveled surface.
Tighten the cap.
Fill with cool water only.
Crack in Tank.
Hot water will cause tank to pressurize.
Tanks will crack if hit or dropped.
Fill with cool water only.
Handle tank with care. If there is crack on
tank, replace with a new tank.
Film on Tank.
Mineral deposits.
Clean/disinfect tank as instructed in weekly
cleaning instructions.
Mist output
minimal to none.
Scale build up on transducer. Replace the dimineralization cartridge by
following the maintenence instructions.
Reduced or no mist.
Out of water.
Improper Maintenance.
Demineralization cartridge not seated
properly.
Using low setting.
Fill tank.
Increase setting to High.
Properly seat the demineralization cartridge and
reseat tank.
Follow cleaning and maintenance instructions.
Appearance of
minerals or white
dust.
The demineralization cartridge is
assembled upside down and the tank
will not sit flush. This prevents the tank
plunger value from being activated to
all water to flow.
Use distilled water in your humidifier. This will
help reduce the precipitation of minerals or white
dust.
In addition, use a demineralization cartridge to
help reduce mineral build-up and “white-dust”
caused by hard water.
Tank does not fit
properly on the
base.
The demineralization cartridge is not
seated correctly in the base.
Confirm the proper placement of the
demineralization cartridge. The cartridge is
marked with "THIS SIDE UP".
FREQUENTLY ASKED QUESTIONS
Question Answer
What are the
variables that affect
run time?
The estimated run time for this humidifier is based on average room conditions. The actual run time
of your humidifier is dependent on numerous variables such as:
Air exchange in the room where the humidifier is placed.
Room construction of the room where the humidifier is placed.
Temperature of the room where the humidifier is placed.
Humidity levels in the room where the humidifier is placed.
Movement of occupants and the opening and closing of doors in the room where the humidifier
is placed.
Home furnishings in the room where the humidifier is placed.
How do I remove
film on water tank?
Vinegar and water soak will remove it within 20 mins.
How can I extend
the run time?
Run your unit on the lowest setting.
If your unit has electronics, set it to your desired humidity level. The unit will turn on and off,
which will extend the run time.
Fill the tank all the way full, place it on the base, let the water empty into the base until it stops
bubbling, then refill the tank full again. This ensures maximum water capacity and will extend
run time.
If you have any questions regarding your product or would like to learn more about other Holmes
®
products, please visit
our website at www.holmesproducts.com. For inquiries regarding recycling and proper disposal of this product, please
contact your local waste management facility.
199410 HUL9500B_19EM1 Printed In China
GCDS-HOL635678-JC
4. To rinse, pour 1 cup of cool tap water in the air inlet
area. Allow to reach transducer area. Pour out water.
To Disinfect Humidifier Base and Tank:
1. Fill humidifier tank 1/2 full with water and 1/2
tablespoon (0.25oz/7.4ml) of chlorine bleach.
2. Return tank to base. Allow to set for 20 minutes. Use
clean water in tank to flush system. Do not allow
water to get in the fan housing.
3. Carefully empty the tank after 20 minutes, and rinse
with warm water until you cannot detect any bleach
smell. Dry with a clean cloth or paper towel.
4. Discard bleach water in the base. pour towards the
left corner of base.
5. To clean the humidifier base, pour out all access
water. Rinse thoroughly to remove any sediment to
dirt. Wipe clean and dry with a clean cloth or paper
towel. Do not use metal cleaning utensils of abrasive
cleansers.
NOTE: Do not scrape the transducer with any other object
other than the brush provided. Damage could occur and
cause malfunction.
STORAGE INSTRUCTIONS
When not using your humidifier for an extended period
of time:
1. Clean, rinse and thoroughly dry the humidifier as
directed in weekly maintenance. DO NOT leave any
water in the unit when storing. Leaving water in the
unit may render the unit inoperable for the following
season.
2. Place the humidifier in the original carton and store
in a cool, dry place.
REPLACEMENT ACCESSORIES
To order the replacement accessories you can do any of
the following:
Visit your local retailer
Go to
www.holmesproducts.com
PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS
Owner’s Guide
HUL9500B
Warm or Cool Ultrasonic
Humidifier
HUL9500B_19EM1.indd 1 5/21/19 10:10

Specifications

Holmes HUL9500B-U-FCA-2 Questions and Answers