Beko SLER30524SS 30 Inch Slide-In Electric Range with 5 Elements, 5.2 cu. ft. True European

Owners Guide - Page 21

For SLER30524SS.

PDF File Manual, 28 pages, Read Online | Download pdf file

SLER30524SS photo
Loading ...
Loading ...
Loading ...
21
1 Terminal block
2 Screws
3 Power cord / conduit plate
After completing connections put
terminal cover back to the original
location and tighten the screw.
Power cord connections
!
Warning: Electrical shock hazard!
Frame grounded to neutral of appliance
through a link. Grounding through the
neutral conductor is prohibited for
new branch-circuit installations (1996
NEC); mobile homes; and recreational
vehicles, or in an area where local
codes prohibit grounding through the
neutral conductor. For installations
where grounding through the neutral
conductor is prohibited.
1. Disconnect the link from the neutral.
2. Use grounding terminal or lead to
ground unit.
3. Connect neutral terminal or lead to
branch circuit neutral in usual manner
(when the appliance is to be connected
by means of a cord kit, use 4-conductor
cord or conduit for this purpose.
!
Warning: Do not loosen the factory
installed nut connections which secure
the range wiring to terminal block.
Electrical failure or loss of electrical
connection may occur if these 3 nuts
are loosened or removed.
Power cord strain relief installation
Purchase a strain relief before
installation.
1. Using the 1-1/8 in. or 7/8 in. diameter
opening insert the strain relief and
power cord through the opening and
secure the strain relief as directed in
this instructions.
!
Warning: DO NOT install the power cord
without a strain relief.
1 Terminal block
2 Grounding wire
3 Strain relief
4 Power cord
!
Caution: The grounding wire is installed
on this range which connects the enter
terminal of the neutral terminal block to
the range chassis. The grounding wire
is connected to the range by the center,
lowest screw. The grounding wire must
not be removed unless National, State
or Local Codes do not permit use of a
ground strap.
!
Caution: If the grounding wire is
removed for any reason, a separate
ground wire must be connected to the
separate ground screw attached to
the range chassis and to an adequate
ground
Instructions supplied with the
strain relief clamp and install.
INSTALLATION
Loading ...
Loading ...
Loading ...