LED & STATUS DISPLAY
Select “UP” or “DOWN” controls to adjust the
roller laminating temperature.
Manually adjust the roller temperatures to
suit the thickness of laminating stock.
Select function to laminate with ‘MOUNT BOARD’.
A function for laminating hard board more than 1mm
thickness. The function selects temperature 130°c and
motor speed “1”.
Select function to ‘MEASURE’ the actual
temperature of rollers.
The button can be pressed anytime for an im-
mediate read out in the temperature display.
Select function for ‘COLD’ or no-heat lamination.
Cold lamination automatically selects temperature and
motor speed of “0”. If roller temperature is above 60°c,
motor speed of “2” will operate until rollers have cooled
safely. This action will prevent heat damage to the
rollers.
Select function for laminating with ‘CARRIER’.
The function for laminating pouches with
Carriers. The function selects 100°c and motor
speed “2”.
Select function for ‘PRE-HEAT’ .
Pre-Heat can be selected as a ‘Stand-By’ function ideal
for extended periods of use. The function operates at
80°c and motor speed “2”, until another function is
selected.
Select function for ‘HOT’ lamination. Hot lamination for normal hot pouch films. For 3 mil pouch, the machine will select
temperature of 90°c and motor speed of “5”. This is ideal for 20lb copy paper and 3 mil pouch. For thicker pouches, select the
corresponding engine speed followed by temperature adjustment. Adjustment to temperature using “UP” and “DN” buttons to
suit the thickness of paper as required.
EG:
10 Mil = motor speed 2
7 Mil = motor speed 3
5 Mil = motor speed 5
3 Mil = motor speed 5
5
Indicates roller temperature (pre-set and actual).
“READY” LED switches to show the roller temperature is
ready to laminate.
Indicates running speed of the rollers.
Function LED displays showing the selected function in
operation.
TEMPERATURE ADJUSTMENT & FUNCTION CONTROLS
SPEED & MOTOR CONTROLS
“STOP” function.
Press and hold to stop the rollers running. Do
not use for long periods especially when the
roller temperature is above 90°c.
“Reverse” function.
Press and hold to reverse the rollers. This will help
remove mis-fed pouches.
Select the motor speed to suit the chosen pouch thickness. Then adjust temperature to suit paper thickness if required.
EG:
motor speed 1 = mounting board
motor speed 2 = 10 mil (250 micron & carriers)
motor speed 3 = 10, 7 mil (200, 175, 150 micron)
motor speed 5 = 5, 4, 3, mil (125, 100, 80 micron)