Legal Informaon
About this Document
●
This Document includes instrucons for using and managing the Product. Pictures, charts,
images and all other
informaon hereinaer are for descripon and explanaon only.
●
The
informaon contained in the Document is subject to change, without noce, due to
rmware updates or other reasons. Please nd the latest version of the Document at the
Hikvision website ( hps://www.hikvision.com ). Unless otherwise agreed, Hangzhou Hikvision
Digital Technology Co., Ltd. or its aliates (hereinaer referred to as "Hikvision") makes no
warranes, express or implied.
●
Please use the Document with the guidance and assistance of professionals trained in
supporng the Product.
About this Product
●
This product can only enjoy the aer-sales service support in the country or region where the
purchase is made.
●
If the product you choose is a video product, please scan the following QR code to obtain the
"Iniaves on the Use of Video Products", and read it carefully.
Acknowledgment of Intellectual Property Rights
●
Hikvision owns the copyrights and/or patents related to the technology embodied in the
Products described in this Document, which may include licenses obtained from third pares.
●
Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part
of this Document may be excerpted, copied, translated, or modied in whole or in part by any
means without
wrien permission.
●
and other Hikvision's trademarks and logos are the properes of Hikvision in
various
jurisdicons.
●
Other trademarks and logos menoned are the properes of their respecve owners.
LEGAL DISCLAIMER
●
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS DOCUMENT AND THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED "AS
IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES, EXPRESS OR
DS-K27XX Series Access Controller User Manual
i

IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR
FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK.
IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL,
INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR
LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR
LOSS.
●
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION,
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK,
VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE
TIMELY TECHNICAL SUPPORT IF REQUIRED.
●
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE
SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.
ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT
INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY
RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE
DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR
PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT
RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF
HUMAN RIGHTS ABUSES.
●
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS DOCUMENT AND THE APPLICABLE LAW, THE
LATTER PREVAILS.
Data
Protecon
●
To protect data, the development of Hikvision Products incorporates privacy by design
principles. For example, for Products with facial
recognion features, biometrics data is stored in
your Products with encrypon method; for ngerprint Products, only ngerprint template will be
saved, which is impossible to reconstruct a
ngerprint image.
●
As a data controller/processor, you may process personal data, including collecon, storage, use,
processing, disclosure,
deleon, etc. You are advised to pay aenon to and comply with
applicable laws and regulaons related to the protecon of personal data, including without
limitaon, conducng security controls to safeguard personal data, such as, implemenng
reasonable administrave and physical security controls, conduct periodic reviews and the
assessments of the
eecveness of your security controls.
© Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
DS-K27XX Series Access Controller User Manual
ii

Available Model
Product Name Model
Access Controller DS-K2701X Series Access Controller
DS-K2702X Series Access Controller
DS-K2702WX-E1 Series Access Controller
DS-K2704X Series Access Controller
DS-K2708X Series Access Controller
Access Module DS-K2M002X Access Module
DS-K27XX Series Access Controller User Manual
iii

Regulatory Informaon
FCC Informaon
Please take aenon that changes or modicaon not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable
protecon against harmful interference in a residenal installaon. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the
instrucons, may cause harmful interference to radio communicaons. However, there is
no guarantee that interference will not occur in a parcular installaon. If this equipment does
cause harmful interference to radio or television
recepon, which can be determined by turning
the equipment o and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the
separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit
dierent from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC
Condions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two
condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired
operaon.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
DS-K27XX Series Access Controller User Manual
iv

under the EMC Direcve 2014/30/EU, RE Direcve 2014/53/EU,the RoHS Direcve
2011/65/EU
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed
of as unsorted municipal waste in the European Union. For proper recycling, return
this product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated
collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentaon for specic baery informaon. The baery is marked with this
symbol, which may include
leering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the
baery to your supplier or to a designated
collecon point. For more informaon see:www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to
the following two
condions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired
operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence.
L'exploitaon est autorisée aux deux condions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2.
l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmier by Industry Canada. To reduce
potenal radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut fonconner
avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par
Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intenon des
autres ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
DS-K27XX Series Access Controller User Manual
v

Cet équipement doit être installé et ulisé à une distance minimale de 20 cm entre le radiateur et
votre corps.
DS-K27XX Series Access Controller User Manual
vi

Safety Instrucon
These instrucons are intended to ensure that user can use the product correctly to avoid danger
or property loss.
The
precauon measure is divided into Dangers and Cauons:
Dangers: Neglecng any of the warnings may cause serious injury or death.
Cauons: Neglecng any of the cauons may cause injury or equipment damage.
Dangers: Follow these safeguards to prevent
serious injury or death.
Cauons: Follow these precauons to prevent
potenal injury or material damage.
Danger:
●
All the electronic operaon should be strictly compliance with the electrical safety regulaons,
re prevenon regulaons and other related regulaons in your local region.
●
Please use the power adapter, which is provided by normal company. The power consumpon
cannot be less than the required value.
●
Do not connect several devices to one power adapter as adapter overload may cause over-heat
or
re hazard.
●
Please make sure that the power has been disconnected before you wire, install or dismantle the
device.
●
When the product is installed on wall or ceiling, the device shall be
rmly xed.
●
If smoke, odors or noise rise from the device, turn
o the power at once and unplug the power
cable, and then please contact the service center.
●
Do not ingest baery, Chemical Burn Hazard.
This product contains a
coin/buon cell baery. If the coin/buon cell baery is swallowed, it
can cause severe internal burns in just 2 hours and can lead to death.
Keep new and used
baeries away from children. If the baery compartment does not close
securely, stop using the product and keep it away from children. If you think baeries might have
been swallowed or placed inside any part of the body, seek immediate medical
aenon.
●
If the product does not work properly, please contact your dealer or the nearest service center.
Never
aempt to disassemble the device yourself. (We shall not assume any responsibility for
problems caused by unauthorized repair or maintenance.)
DS-K27XX Series Access Controller User Manual
vii

Cauons:
●
Do not drop the device or subject it to physical shock, and do not expose it to high
electromagnesm radiaon. Avoid the equipment installaon on vibraons surface or places
subject to shock (ignorance can cause equipment damage).
●
Do not place the device in extremely hot (refer to the specicaon of the device for the detailed
operang temperature), cold, dusty or damp locaons, and do not expose it to high
electromagnec radiaon.
●
The device cover for indoor use shall be kept from rain and moisture.
●
Exposing the equipment to direct sun light, low venlaon or heat source such as heater or
radiator is forbidden (ignorance can cause re danger).
●
Do not aim the device at the sun or extra bright places. A blooming or smear may occur
otherwise (which is not a malfuncon however), and aecng the endurance of sensor at the
same me.
●
Please use the provided glove when open up the device cover, avoid direct contact with the
device cover, because the acidic sweat of the ngers may erode the surface coang of the device
cover.
●
Please use a so and dry cloth when clean inside and outside surfaces of the device cover, do
not use alkaline detergents.
●
Please keep all wrappers
aer unpack them for future use. In case of any failure occurred, you
need to return the device to the factory with the original wrapper. Transportaon without the
original wrapper may result in damage on the device and lead to addional costs.
●
Improper use or replacement of the
baery may result in hazard of explosion. Replace with the
same or equivalent type only. Dispose of used baeries according to the instrucons provided by
the
baery manufacturer.
DS-K27XX Series Access Controller User Manual
viii

Contents
Chapter 1 Features ..................................................................................................................... 1
Chapter 2 Appearance ................................................................................................................ 2
2.1 Appearance and Interfaces of 1-Door/2-Door/4-Door/8-Door Access Controller ................. 2
2.2 Access Module Appearance ................................................................................................... 6
2.3 Indicator Descripon ............................................................................................................. 7
Chapter 3 Terminal Wiring .......................................................................................................... 9
3.1 Wiring Descripon ................................................................................................................. 9
3.2 Wiegand Card Reader Wiring ............................................................................................... 12
3.3 RS-485 Card Reader Wiring .................................................................................................. 13
3.4 Door Lock Wiring ................................................................................................................. 14
3.5 Alarm Wiring ........................................................................................................................ 14
3.6 Exit Buon Wiring ................................................................................................................ 14
3.7 Door Contact Wiring ............................................................................................................ 15
3.8 Fire Alarm Module Wiring .................................................................................................... 15
Chapter 4
Installaon ............................................................................................................... 17
4.1 Install Access Controller ....................................................................................................... 17
4.2 Install Access Controller Main Board ................................................................................... 19
Chapter 5
Sengs .................................................................................................................... 23
Chapter 6 Acvaon ................................................................................................................. 24
6.1 Acvate via Web Browser .................................................................................................... 24
6.2
Acvate via SADP ................................................................................................................. 24
Chapter 7 Typical Applicaon ................................................................................................... 27
Chapter 8 Quick Operaon via Web Browser ............................................................................ 28
8.1 Set Security
Queson ........................................................................................................... 28
8.2 Select Language ................................................................................................................... 28
8.3 Time Sengs ........................................................................................................................ 28
DS-K27XX Series Access Controller User Manual
ix

Chapter 9 Operaon via Web Browser ...................................................................................... 29
9.1 Login .................................................................................................................................... 29
9.2 Forget Password ................................................................................................................... 29
9.3 Module
Descripon ............................................................................................................. 29
9.4 Access Control Management ............................................................................................... 30
9.4.1 Overview ..................................................................................................................... 30
9.4.2 Search Event ................................................................................................................ 30
9.4.3 Access Point Management .......................................................................................... 31
9.4.4 Permission Management ............................................................................................ 36
9.4.5 Access Control Applicaon .......................................................................................... 39
9.5 Person Management ............................................................................................................ 47
9.5.1 Add Organizaon ........................................................................................................ 47
9.5.2 Add Person .................................................................................................................. 47
9.6 Device Management ............................................................................................................ 50
9.6.1 Search Not Added Device ........................................................................................... 50
9.6.2 Add Access Module ..................................................................................................... 50
9.6.3 Area Management ...................................................................................................... 53
9.7 System and Maintenance ..................................................................................................... 53
9.7.1 View Device
Informaon ............................................................................................. 53
9.7.2 Set Time ...................................................................................................................... 53
9.7.3 Set DST ........................................................................................................................ 54
9.7.4 Change Administrator's Password ............................................................................... 54
9.7.5 Account Security
Sengs ............................................................................................ 55
9.7.6 View Online User ........................................................................................................ 55
9.7.7 View Open Source Soware License on PC Web ........................................................ 55
9.7.8 View Device Arming/Disarming
Informaon .............................................................. 56
9.7.9 Network Sengs ......................................................................................................... 56
9.7.10 Event
Sengs ............................................................................................................ 59
DS-K27XX Series Access Controller User Manual
x

9.7.11 Access Conguraon ................................................................................................. 62
9.7.12 Card Sengs ............................................................................................................. 64
9.7.13 Maintenance and Security ........................................................................................ 66
9.7.14
Cercate Management ........................................................................................... 68
Chapter 10 Other Plaorms to Congure .................................................................................. 70
Appendix A. Dimension ............................................................................................................ 71
DS-K27XX Series Access Controller User Manual
xi

Chapter 1 Features
●
The access controller and access module are cascaded by RS-485. The 4-door access controller
can control up to 128 doors, the 2-door access controller can control up to 126 doors, and the 1-
door access controller can control up to 125 doors.
●
Supports access control applicaon.
●
Supports management via Web client.
●
Supports RS-485 to achieve hand-in-hand cascade.
●
Supports backup
baery charging and discharging.
Note
Only paral models support this funcon.
●
Uplink supports wired network or Wi-Fi; Downlink supports Wiegand (customizable) and OSDP.
Note
Only paral models support Wi-Fi funcon.
●
In addion to the convenonal DC 12 V power supply, device can also be powered via POE.
Note
Only paral models support this funcon.
●
The main board sells separately and supports rail mounng.
DS-K27XX Series Access Controller User Manual
1

Chapter 2 Appearance
2.1 Appearance and Interfaces of 1-Door/2-Door/4-Door/8-Door Access
Controller
The appearance and interfaces of 1-door/2-door/4-door/8-door access controller are as follows.
Appearance and Interfaces of 1-Door Access Controller
Figure 2-1 Appearance and Interfaces of 1-Door Access Controller
DS-K27XX Series Access Controller User Manual
2

Figure 2-2 Appearance and Interfaces of 1-Door Access Controller Main Board
Appearance and Interfaces of 2-Door Access Controller
Note
●
Only paral models support Wi-Fi and POE funcon.
●
PoE model devices need to be aware of the following:
1. The switch specicaon is 30 W.
2. PoE and Wi-Fi
funcon cannot be used at the same me.
3. If the total power of the incoming locks exceeds 10 W, an addional separate power supply is
required for one of the locks.
4. Supports access to up to 4 card readers.
DS-K27XX Series Access Controller User Manual
3

Figure 2-3 Appearance and Interfaces of 2-Door Access Controller
Figure 2-4 Appearance and Interfaces of 2-Door Access Controller Main Board
DS-K27XX Series Access Controller User Manual
4

Appearance and Interfaces of 4-Door Access Controller
Figure 2-5 Appearance and Interfaces of 4-Door Access Controller
Figure 2-6 Appearance and Interfaces of 4-Door Access Controller Main Board
DS-K27XX Series Access Controller User Manual
5

Appearance and Interfaces of 8-Door Access Controller
Figure 2-7 Appearance and Interfaces of 8-Door Access Controller
2.2 Access Module Appearance
View the access module appearance.
DS-K27XX Series Access Controller User Manual
6

Figure 2-8 Access Module Appearance
2.3 Indicator
Descripon
The indicator descripon of 1-door/2-door/4-door/8-door access controller and access module is
as follows.
Device Name
Descripon
1-Door Access Controller There are a total of 9 indicators: a power
supply indicator, a working status indicator, a
network indicator, a door status and 5 RS-485
status indicators.
2-Door Access Controller There are a total of 11 indicators: a power
supply indicator, a working status indicator, a
network indicator, a Wi-Fi indicator, 5 RS-485
status indicators and 2 door status indicators.
DS-K27XX Series Access Controller User Manual
7

Note
Some models do not support Wi-Fi
indicators.
4-Door Access Controller There are a total of 12 indicators: a power
supply indicator, a working status indicator, a
network indicator, 5 RS-485 status indicators
and 4 door status indicators.
8-Door Access Controller Access Controller: There are a total of 12
indicators: a power supply indicator, a
working status indicator, a network indicator,
5 RS-485 status indicators and 4 door status
indicators.
Access module: There are a total of 6
indicators: a power supply indicator, a
working status indicator, 2
communicaon
status indicators, and 2 door status
indicators.
Access Module There are a total of 6 indicators: a power
supply indicator, a working status indicator, 2
communicaon status indicators, and 2 door
status indicators.
Note
When the working status indicator is red, it means that the device is powered on; When the
working status indicator is ashing green, it means that the device is added to the plaorm. When
the door status indicator is on, it means that the door is open, and the light is o means that the
door is closed. When the other status indicators are on, it means
connecng, and the light o
means that it is not connected.
DS-K27XX Series Access Controller User Manual
8

Chapter 3 Terminal Wiring
Terminal Wiring Descripon of the Access Controller.
3.1 Wiring Descripon
The wiring of 1-door/2-door/4-door/8-door access controller are as follows.
Figure 3-1 The Wiring of 1-Door Access Controller
DS-K27XX Series Access Controller User Manual
9

Figure 3-2 The Wiring of 2-Door Access Controller
DS-K27XX Series Access Controller User Manual
10

Figure 3-3 The Wiring of 4-Door Access Controller
DS-K27XX Series Access Controller User Manual
11

Figure 3-4 The Wiring of Access Module
3.2 Wiegand Card Reader Wiring
You can view the Wiegand card reader wiring diagram.
DS-K27XX Series Access Controller User Manual
12

Figure 3-5 Wiegand Card Reader Wiring Diagram
Note
You must connect the OK/ERR/BZ, if using access controller to control the LED and buzzer of the
Wiegand card reader.
3.3 RS-485 Card Reader Wiring
You can view the RS-485 card reader wiring diagram.
Figure 3-6 RS-485 Card Reader Wiring Diagram
Note
●
If the card reader is installed too far away from the access controller, you can use an external
power supply.
●
It is recommended to use hand-in-hand wiring to connect the RS-485 card reader.
DS-K27XX Series Access Controller User Manual
13

3.4 Door Lock Wiring
You can view the door lock wiring diagram.
Figure 3-7 Wiring Diagram of Door Lock
3.5 Alarm Wiring
You can view the alarm wiring diagram.
Figure 3-8 Alarm Wiring
3.6 Exit
Buon Wiring
You can view the exit buon wiring diagram
DS-K27XX Series Access Controller User Manual
14

Figure 3-9 Exit Buon Wiring
3.7 Door Contact Wiring
You can view the door contact wiring diagram.
Figure 3-10 Door Contact Wiring
3.8 Fire Alarm Module Wiring
You can view the
re alarm module wiring diagram.
DS-K27XX Series Access Controller User Manual
15

Figure 3-11 Fire Alarm Module Wiring
DS-K27XX Series Access Controller User Manual
16

Chapter 4 Installaon
4.1 Install Access Controller
The access controller chassis can be wall-mounted.
Steps
Note
●
Indoor use only.
●
The minimum bearing weight of the wall or other places should be 3 mes heavier than the
device weight.
●
Here we take 1-door access controller as example.
1.
Fix 3 SC-KA4X45 screws to the wall, and 3 to 5 mm thread should be reserved on the top of the
screw (to facilitate subsequent hanging of the chassis).
Figure 4-1 Fix Chassis
2.
Open the chassis cover and press the holes on the chassis body with the screws reserved on the
wall. Then aach the chassis from top to boom onto the screws.
DS-K27XX Series Access Controller User Manual
17

Figure 4-2 Hang Chassis
3.
Close the chassis cover to complete the installaon.
DS-K27XX Series Access Controller User Manual
18

Figure 4-3 Complete Installaon
4.2 Install Access Controller Main Board
The access controller main board can be wall-mounted.
Steps
Note
●
Indoor use only.
●
The minimum bearing weight of the wall or other places should be 3 mes heavier than the
device weight.
●
Here we take 1-door access controller main board as example.
1.
Use 2 SC-KA4X25 screws to secure the rail to the wall.
DS-K27XX Series Access Controller User Manual
19

Figure 4-4 Secure Rail
2.
Align the rail groove on the boom of the device with the rail, press the device, and snap the
device to the rail with the tabs on the
boom.
DS-K27XX Series Access Controller User Manual
20

Figure 4-5 Fix Device
3.
Installaon completed.
DS-K27XX Series Access Controller User Manual
21

Figure 4-6 Complete Installaon
DS-K27XX Series Access Controller User Manual
22

Chapter 5 Sengs
Hardware Inializaon
Hold the restore buon for 5s to inialize the hardware.
Fire Relay NO/NC
The posion of the re jumper cap posion and the related NO/NC status are as follows:
Note
This operaon requires disassembling the upper and lower shells of the device, which is
recommended by a professional.
Figure 5-1 Fire Jumper Cap Posion Descripon
Normally Closed Status Normally Open Status
DS-K27XX Series Access Controller User Manual
23

Chapter 6 Acvaon
You should acvate the device before the rst login. Aer powering on the device, the system will
switch to Device
Acvaon page.
Acvaon via the device, SADP tool and the client soware are supported.
The default values of the device are as follows:
●
The default IP address: 192.0.0.64
●
The default port No.: 8000
●
The default user name: admin
6.1
Acvate via Web Browser
You can acvate the device via the web browser.
Steps
1.
Enter the device default IP address (192.0.0.64) in the address bar of the web browser, and press
Enter.
Note
Make sure the device IP address and the computer's should be in the same IP segment.
2.
Create a new password (admin password) and conrm the password.
Cauon
STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of
your own choosing (using a minimum of 8 characters, including upper case leers, lower case
leers, numbers, and special characters) in order to increase the security of your product. And
we recommend you reset your password regularly, especially in the high security system,
reseng the password monthly or weekly can beer protect your product.
Note
Characters containing admin and nimda are not supported to be set as acvaon password.
3.
Click Acvate.
4.
Edit the device IP address. You can edit the IP address via the SADP tool, the device, and the
client soware.
6.2
Acvate via SADP
SADP is a tool to detect, acvate and modify the IP address of the device over the LAN.
DS-K27XX Series Access Controller User Manual
24

Before You Start
●
Get the SADP soware from the supplied disk or the ocial website hp://
www.hikvision.com/en/ , and install the SADP according to the prompts.
●
The device and the PC that runs the SADP tool should be within the same subnet.
The following steps show how to acvate a device and modify its IP address. For batch acvaon
and IP addresses modicaon, refer to User Manual of SADP for details.
Steps
1.
Run the SADP soware and search the online devices.
2.
Find and select your device in online device list.
3.
Input new password (admin password) and
conrm the password.
Cauon
STRONG PASSWORD RECOMMENDED-We highly recommend you create a strong password of
your own choosing (using a minimum of 8 characters, including upper case leers, lower case
leers, numbers, and special characters) in order to increase the security of your product. And
we recommend you reset your password regularly, especially in the high security system,
reseng the password monthly or weekly can beer protect your product.
Note
Characters containing admin and nimda are not supported to be set as acvaon password.
4.
Click Acvate to start acvaon.
Status of the device becomes Acve aer successful acvaon.
5.
Modify IP address of the device.
1) Select the device.
DS-K27XX Series Access Controller User Manual
25

2) Change the device IP address to the same subnet as your computer by either modifying the IP
address manually or checking Enable DHCP.
3) Input the admin password and click Modify to acvate your IP address modicaon.
DS-K27XX Series Access Controller User Manual
26

Chapter 7 Typical Applicaon
The typical applicaon for access controller, access module, lock and plaorm is as follows.
Figure 7-1 Typical Applicaon
1
No RS-485 redundant protecon max. 128 doors.
Note
The DS-K2704X series support up to 128 doors; K2702X series support up to 126 doors;
K2701x series support up to 125 doors.
2 With RS-485 redundant protecon max. 64 doors.
3 Max. 4 doors.
DS-K27XX Series Access Controller User Manual
27

Chapter 8 Quick Operaon via Web Browser
8.1 Set Security Queson
If you forget the device acvaon password, you can change the password via security quesons.
Set the security quesons before conguraon.
Click in the top right of the web page to enter the Change Password page. You can click Skip to
skip the step. Or select three quesons to answer and click Next.
8.2 Select Language
You can select a language for the device system.
Click in the top right of the web page to enter the Device Language Sengs page. You can
select a language for the device system from the drop-down list.
By default, the system language is English.
Note
Aer you change the system language, the device will reboot automacally.
8.3 Time Sengs
Click in the top right of the web page to enter the wizard page.
Time Zone
Select the device located me zone from the drop-down list.
Time Sync.
NTP
You should set the NTP server's IP address, port No., and interval.
Manual
By default, the device
me should be synchronized manually. You can set the device me
manually or check Sync. with Computer Time to synchronize the device me with the
computer's
me.
Server Address/NTP Port/Interval
You can set the server address, NTP port, and interval.
DST
You can view the DST start me, end me and bias me.
DS-K27XX Series Access Controller User Manual
28

Chapter 9 Operaon via Web Browser
9.1 Login
You can login via the web browser or the remote conguraon of the client soware.
Note
●
Make sure the device is acvated. For detailed informaon about acvaon, see Acvaon
Chapter.
●
It is recommended to log in through the Chrome browser.
Login via Web Browser
Enter the device IP address in the address bar of the web browser and press Enter to enter the
login page.
Enter the device user name and the password. Click Login.
Login via Remote
Conguraon of Client Soware
Download and open the client soware. Aer adding the device, click to enter the Conguraon
page.
9.2 Forget Password
If you forget the password when logging in, you can change the password by security quesons.
On the login page, click Forget Password.
Answer the security quesons.
Click Next, create a new password and conrm it.
9.3 Module
Descripon
You can set Person management, device management, access control, system and maintenance
parameters.
Click on the right side to open the module descripon page and view the descripon of each
module. Click each hyperlink to jump to the corresponding
sengs page.
Conguraon process is as follows:
DS-K27XX Series Access Controller User Manual
29

9.4 Access Control Management
9.4.1 Overview
You can select the area and control the door status, view the device status, view the event, view
the person informaon, network status, basic informaon, and device capacity. You can also enter
the page from quick start part.
Login the web browser and enter the Access Control → Overview .
Door Status
Click View More to view and control all doors' status.
/ / /
Set the door status as unlock, closed, remain open, or remain closed.
Quick Start
Click Add Person, Add Device, System Sengs, or System and Maintenance on the upper-right
of the page to quick enter the page to
congure parameters.
Event
You can view the event Employee ID, Name, Card No., Event Type, Time, and Operaon.
You can also click View More to enter the search condions, including the event type, employee
ID, the name, the card No., the start
me, and the end me, and click Search. The results will be
displayed on the right panel.
Device Status
View the other linked devices' status.
Person Informaon
View the person number, card number, ngerprint No.
Network Status
You can view the connected and registered status of wired network, wireless network, ISUP and
cloud service.
Basic
Informaon
You can view the model, serial No. and rmware version.
Device Capacity
You can view the person, card, ngerprint, and event capacity.
9.4.2 Search Event
Click Access Control → Event Search to enter the Search page.
DS-K27XX Series Access Controller User Manual
30

Enter the search condions, including the event type, the employee ID, the name, the card No., the
start me, and the end me, and click Search.
Note
The searched name should be up to 32 bits.
The results will be displayed on the right panel.
9.4.3 Access Point Management
Click Access Control → Access Point Management, you can view the doors associated with the
access controller and the card readers associated with the doors.
Hover the mouse over the door or card reader on the right side of the interface, and you can click
to
congure the door parameters and the card reader authencaon parameters.
Set Door Parameters
Set the door parameters.
You can enter the door parameters page from the following 2 methods:
1. Click Access Control → Access Point Management . Hover the mouse on the door and click
to
enter the door parameters page.
2. Click Access Control →
Conguraon → Door Parameters .
Click Save to save the sengs aer the conguraon. Click Copy to to copy the door's parameters
to other doors.
DS-K27XX Series Access Controller User Manual
31

Figure 9-1 Set Door Parameters
Door Name
You can create a name for the door.
Area
Select an added area or click Add Area to add a new area for the door.
Open
Duraon
Set the door unlocking duraon. If the door is not opened for the set me, the door will be
locked.
Door Open Timeout Alarm
An alarm will be triggered if the door has not been closed within the congured me duraon.
Door Contact Type
You can set the door contact as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Closed.
Exit
Buon Type
You can set the exit buon as Remain Open or Remain Closed according to your actual needs.
By default, it is Remain Open.
Extended Open Duraon
The door contact can be enabled with appropriate delay aer person with extended access
needs swipes her/his card.
Door Remain Open
Duraon with First Person
DS-K27XX Series Access Controller User Manual
32

Set the door open duraon when rst person is in. Aer the rst person is authorized, it allows
mulple persons access the door or other authencaon acons.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The
specic person can open the door by inpung the super password.
Dismiss Code
When the alarm is triggered, you can enter the dismiss code to dismiss the alarm.
Note
The duress code and the super password should be dierent.
Set Authencaon Parameters
You can enter the authencaon parameters page from the following 2 methods:
1. Click Access Control → Access Point Management . Hover the mouse on the card reader and
click
to enter the authencaon parameters page.
2. Click Access Control → Conguraon → Authencaon Parameters .
Click Save to save the
sengs aer the conguraon. Click Copy to to copy the card reader's
parameters to other card readers.
Note
The funcons vary according to dierent models. Refers to the actual device for details.
DS-K27XX Series Access Controller User Manual
33

Figure 9-2 Set Authencaon Parameters
Card Reader Parameter Conguraon
Card Reader Name
Create a name for the card reader.
DS-K27XX Series Access Controller User Manual
34

Card Reader Type/Card Reader Descripon
View the card reader's type and descripon.
Enable Authencaon Device
Enable the authencaon funcon.
Authencaon
Interval
You can set the authencaon interval of the same person when authencang. The same
person can only authencate once in the congured interval. A second authencaon will be
failed.
Alarm of Max. Failed
Aempts
Enable to report alarm when the card reading aempts reach the set value.
Max. Authencaon Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Communicaon with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine automacally.
Max. Interval When Entering Password
When you entering the password on the card reader, if the interval between pressing two
digits is longer than the set value, the digits you pressed before will be cleared automacally.
OK LED Polarity/Error LED Polarity/Buzzer Polarity
Set OK LED Polarity/Error LED Polarity/Buzzer Polarity of the access control device according
to the card reader parameters. Generally, adopts the default sengs.
Tampering Detecon
Enable the an-tamper detecon for the card reader.
QR Code
Enable the funcon and the card reader can recognize the QR code for authencaon.
Note
The funcon should be supported by the card reader.
Bluetooth Parameter Conguraon
Enable Bluetooth
Enable the bluetooth funcon and the you can use the bluetooth funcon (e.g. opening
door) on the card reader.
Device Name/Transming Power
Edit the card reader's name and its transming power.
Open Door via Bluetooth
DS-K27XX Series Access Controller User Manual
35

Enable the funcon and you can open the door via bluetooth through App. You should add
the device to the App before use the funcon.
Authencaon Plan Conguraon
Set the authencaon schedule for the card reader.
Select an authencaon type and drag the me duraon on the me schedule table to draw
the authencaon duraon.
Click Clear and drag a me duraon to delete, or click → Clear All to delete all me
duraons.
Set Smart Parameters
Click Access Control → Conguraon → Smart → Smart .
Note
●
The funcons vary according to dierent models. Refers to the actual device for details.
●
Aer conguring the general parameters, all card readers will take eect.
Click Save to save the sengs aer the conguraon.
Fingerprint Recognion
The device support recognion ngerprint aer the funcon is enabled.
Fingerprint Security Level
Select the ngerprint security level.
The higher is the security level, the lower is the false acceptance rate (FAR).
9.4.4 Permission Management
You can set access permission schedule template, holiday schedule template, and set access
permission.
Congure
Schedule Template
Set Access Schedule Template
Access schedule templates are used to set authorized passing me for people. The device provides
three default access schedule templates: all-day template, workday template, and weekend
template. You can also add custom templates according to actual needs.
Steps
1.
Click Access Control → Permission Management → Access Plan Management → + Add.
DS-K27XX Series Access Controller User Manual
36

Figure 9-3 Set Access Schedule Template
2.
Set the template.
Name
Set the template name.
3.
On the weekly schedule template, drag the cursor to draw on the
me bar.
Note
You can set up to 8 access periods per day.
4.
Oponal: Click Clear, and drag on the me bar to delete the corresponding me period.
5.
Oponal: Select Holiday Schedule.
Note
If the holiday schedule and weekly schedule conict, the holiday schedule will be in priority.
1) Click Select Holiday.
2) Select holiday, and set holiday name and date.
3) Click Add.
4) Click and drag on the corresponding
me bar to draw the valid access permission period.
Note
You can set up to 8 access periods per day.
6.
Click Save.
DS-K27XX Series Access Controller User Manual
37

Set Holiday Schedule Template
You can set a legal holiday or a specied date as a holiday. The access permission of holiday is
higher than other basic access permission.
Steps
1.
Click Access Control → Permission Management → Holiday Schedule Management → + Add.
Figure 9-4 Set Holiday Schedule Template
2.
Enter holiday name.
3.
Set the start date and end date of holiday.
4.
Click and drag on the corresponding
me bar to draw the valid access permission period.
5.
Oponal: Move the cursor or click Clear to adjust the me period that has been drawn.
6.
Click Save.
Set Access Permission
Access permission can be dened, and it can be convenient to group according to access points
and manage uniformly.
Steps
1.
Click Access Control → Permission Management → Manage Access Permission → +Add.
DS-K27XX Series Access Controller User Manual
38

Figure 9-5 Set Access Permission
2.
Enter Access Permission Name.
3.
Select Access Schedule. You can click View on the right side to view the access period of
dierent template.
4.
Click + Add to check the access point, and click Save.
5.
Click Save.
9.4.5 Access Control
Applicaon
Open Door with First Person
The rst person can be set to open the door, that is, aer a specic person (the rst person) uses
credenals (such as cards, ngerprints, and faces) to authencate, other personnel can pass
directly, or use
credenals to pass, which is oen used in scenarios where a large number of
people pass.
Before You Start
The device is added. For more informaon about how to add a device, see Device Management .
Steps
1.
Click Access Control → Access Control Applicaon → Open Door with First Person → +Add.
DS-K27XX Series Access Controller User Manual
39

Figure 9-6 Open Door with First Person
2.
Click + Add, and select the access point.
3.
Set the parameters of rst person.
Rule of Opening Door
Remain Open
Aer the rst person is authencated, the door opening status will last for a period of
me, and other personnel can pass without authencaon during this me period. This
funcon is oen used in scenarios where a large number of people pass, such as group
visitors entering tourist aracons. The door-open duraon can be congured.
Authorizaon
The mode is applicable to places with high security requirements. Only aer the person
congured with access permission passes through, other persons can pass through aer
authencang with credenals.
Consecuve Authencaon Times
The number of mes that authencaon is valid during consecuve authencaon periods.
Interval of Consecuve Authencaon
The interval between which the same person can repeat authencaon. Repeated
authencaon by the same person at the congured interval is considered invalid.
First Person Authencaon Time
You can set the start me and eecve me periods of the rst person.
4.
Add the rst person. Click + Add, and select the rst person.
1) Click + Add.
2) Select the
rst person.
DS-K27XX Series Access Controller User Manual
40

3) Click OK.
5.
Click OK.
6.
Oponal: Select mulple rst personnel and click Delete to delete related sengs.
Mul-Factor Authencaon Sengs
Only aer authencang according to the mul-factor authencaon rule, can persons in mul-
factor authencaon groups open the door.
Before You Start
●
The device is added. For more details, see
Device Management .
●
The access point is added. For more details, see Access Point Management .
●
The access schedule is set. For more details, see
Permission Management .
Steps
1.
Click Access Control → Access Control
Applicaon → Mul-Factor Authencaon.
Figure 9-7 Mul-Factor Authencaon Sengs
2.
Click Group Management.
1) Click +, and enter the group name.
2) Click + Add, select person, and click OK.
DS-K27XX Series Access Controller User Manual
41

3) Click OK. The added group will show in the list on the le side of the page. When you select a
group, the informaon about the people in the group will show on the right side of the page.
4) Oponal: Select a group, click + Add, and you can add more group members. Select and click
OK.
3.
Add mul-factor authencaon rule.
1) Click + Add.
2) Set
mul-factor authencaon parameters.
Mul-Factor Authencaon Name
Create the
mul-factor authencaon name.
Access Point
In the drop-down box, select the access point that needs to be applied in the relevant
mul-factor authencaon.
Authencaon Mode
Local Authencaon
Personnel can only open the door aer authencang locally on the device in
accordance with the
authencaon rules.
Local Authencaon + Remotely Opening Door
Personnel can only open the door aer aer authencang locally on the device in
accordance with the authencaon rules and authencang via plaorm remotely.
Local Authencaon + Super Credenal
Personnel can only open the door aer aer authencang locally on the device in
accordance with the
authencaon rules and authencang via super credenal.
Access Schedule
Select the access schedule. Click View to see the template details.
Time Interval of Card Present
Congure the me interval between authencaon for dierent authencang personnel.
Group
Click Link to Organizaon, and select the group. In the added group, you can drag in the
operaon bar to adjust the order, or congure the Number of Persons for Authencaon.
It needs to be authencated according to the order in the list and the Number of Persons
for Authencaon when authencang.
3) Click OK.
4.
Oponal: Select the unnecessary mul-factor authencaon, and click Delete.
5.
Click
to view the access schedule details.
DS-K27XX Series Access Controller User Manual
42

Mul-Door Interlocking Sengs
Mul-door interlocking refers to mulple doors forming an interlocking combinaon, in which one
door can only be opened at most at the same
me, and the other doors must be closed.
Before You Start
●
The device is added. For more details, see
Device Management .
●
The access point is added. For more details, see
Access Point Management .
Steps
1.
Click Access Control → Access Control
Applicaon → Mul-Door Interlocking → + Add.
Figure 9-8 Mul-Door Interlocking Sengs
2.
Create the name.
3.
Click + Add, and select the access points.
4.
Delete unnecessary access points.
-
Select unnecessary access points in the list and click Delete to delete access points in batch.
-
Click to delete the single access point.
5.
Click OK.
6.
You can edit and delete the created
mul-door interlocking.
-
Select the
mul-door interlocking, and click to edit.
-
Select the mul-door interlocking, and click to delete.
-
Select the
mul-door interlocking, and click Delete to delete in batch.
DS-K27XX Series Access Controller User Manual
43

An-Passback Sengs
Personnel must follow the set route for one-way passing. If you do not follow this route for
authencaon, the door will not open. If a person does not enter the door aer swiping the card,
the door will not open when swiping the card again, and the same will apply when going out.
Before You Start
The device is added. For more details, see Device Management .
Steps
1.
Click Access Control → Access Control
Applicaon → An-Passback.
Figure 9-9 An-Passback Sengs
2.
Add an-passback route.
1) Enter name and click Next.
2) Set card reader order. Click Add and select the card reader.
3) Click
to add another card reader.
4) Repeat substep 3 to add mulple card readers.
5)
Oponal: Click a card reader to replace or remove the card reader.
6) Click Next.
7) Set rst card reader.
Disable
●
If the passed card reader of last person recorded by the device is not set
an-passback
or the person is a new user, the an-passback is authencated to pass.
●
If the passed card reader of last person recorded by the device has set
an-passback, it is
necessary to check whether the current card reader is in the sequent an-passback card
reader
aer the last passed card reader, if so, the an-passback is authencated to pass;
if not, the an-passback authencang failed.
Select One Card Reader as First Card Reader
●
In any case, the personnel swipe the rst card reader and the an-passback will be
authencated to pass.
●
If the passed card reader of last person recorded by the device has set an-passback, it is
necessary to check whether the current card reader is in the sequent
an-passback card
reader aer the last passed card reader, if so, the an-passback is authencated to pass;
DS-K27XX Series Access Controller User Manual
44

If not, the an-passback authencang failed. And the an-passback authencang
failed in any other cases.
Note
●
If you violated the an-passback rule, you should swipe the card again from the rst card
reader.
●
Superusers do not follow the above rules.
●
Up to 64 doors can be applied in
an-passback.
3.
Oponal: Set an-passback parameter.
1) Click An-Passback Parameter.
2) You can enable Forgive
An-Passback, and set the Forgive An-Passback schedule.
Forgiving Mode
Forgive An-Passback Regularly
Set the me of Forgive An-Passback, the system will clear the an-passback at the set
me. Aer clearing, the personnel need to follow the an-passback rules again, starng
from the rst card reader to authencate.
Delay Forgiving An-Passback
Set the me of Forgiving An-Passback. The system starts ming aer the person
swipes the card, and aer the set delay me, the an-passback will be cleared. Aer
clearing, the personnel need to follow the an-passback rules again, starng from the
rst card reader to authencate.
Non An-Passback Period
Aer selecng the eecve me, drag to draw the non an-passback period on the me
bar, and the an-passback will not take eect within the congured me period.
Click Clear, and drag on the me bar to delete related me period.
Click
→ Clear All to delete all me periods.
3) Click Save.
4.
You can edit, delete and view the created
an-passback.
-
Select the an-passback, and click to edit.
-
Select the
an-passback, and click to delete.
-
Select mulple an-passback, and click Delete to delete in batch.
-
Select the
an-passback, and click to view the an-passback route.
Remain Open or Closed
Sengs
Set the me period by week during which the door(s) remains locked/unlocked.
Before You Start
●
The device is added. For more details, see Device Management .
●
The access point is added. For more details, see Access Point Management .
DS-K27XX Series Access Controller User Manual
45

Steps
1.
Click Access Control → Access Control Applicaon → Remain Open or Closed.
Figure 9-10 Remain Open or Closed Sengs
2.
Click + Add.
3.
Add the access point.
1) Click + Add.
2) Select the access point, and click OK.
3) You can click
to delete single access point or click Delete to delete in batch.
4.
Set weekly schedule template.
1) Draw
me periods of Remain Open or Closed.
-
Click Remain Open or Remain Closed, and drag over the
me bar of the periods that need to
be remain open or closed.
-
Select Remain Open or Remain Closed, click Quick Operaon, and click All-Day Schedule,
Work Schedule, Weekend Schedule and the
me period will be drawn automacally.
1) Oponal: Click Clear, and drag on the me bar to delete the corresponding me period. Click
→ Clear All to delete all me periods.
5.
Click Save.
DS-K27XX Series Access Controller User Manual
46

9.5 Person Management
9.5.1 Add Organizaon
Aer you add an organizaon, you can add people to the corresponding organizaon.
Steps
1.
Click Person Management to enter the sengs page.
2.
Click + on the
le side of the page and select the parent organizaon.
3.
Create the organizaon name.
4.
Click Save.
The added
organizaon will be listed in the selected parent organizaon.
5.
Oponal: Edit / Delete
-
Click an organizaon, and then click to edit the organizaon informaon.
Select people and click Delete to delete the informaon in batch.
Click Clear All, and all person informaon will be deleted.
-
Click an organizaon and click to delete that organizaon informaon.
9.5.2 Add Person
Add the person's informaon, including the basic informaon, cercate, authencaon and
sengs.
Add Basic
Informaon
Click Person Management → Add to enter the Add Person page.
Add the person's basic informaon, including the employee ID, the person's name, and person
type.
Note
●
If you select Visitor as the person type, you can set the visit mes.
●
Leers are allowed in the employee ID. Up to 32 bits are allowed.
●
Up to 128 bits are allowed in the name.
Click Add to save the sengs.
Click Save and Congure to save the sengs and connue to add next person.
Set Permission Time
Click Person Management → Add to enter the Add Person page.
Enable Long-Term Eecve User, or set Start Time and End Time and the person can only has the
permission within the
congured me period according to your actual needs.
Click Add to save the sengs.
DS-K27XX Series Access Controller User Manual
47

Click Save and Congure to save the sengs and connue to add next person.
Add Card
Click Person Management → Add to enter the Add Person page.
Click Conguraon. If select the Collecon Device as Card Enrollment Staon, you should select
the device model, card type, set buzzing, M1 card encrypon, and sector. Click OK to save.
Note
If select the Collecon Device as Card Enrollment Staon, click Download to download the plug-in
to view the device status. During the installaon, you should close the web page.
If select the Collecon Device as Card Reader, you should select the card reader from the drop-
down list. Click OK to save.
Click Add Card, enter the Card No. and select the Property, and click OK to add the card.
Click Add to save the
sengs.
Click Save and Congure to save the sengs and connue to add next person.
Add Fingerprint
Note
Only devices supporng the ngerprint funcon can add the ngerprint.
Click Person Management → Add to enter the Add Person page.
Click Conguraon. If you selectUSB Fingerprint Recorder, you can click Downloadto download
the plug-in and view the status. Or select Fingerprint and Card Reader and select a card reader
from the drop-down list. Click OK to save.
Note
During the installaon, you should close the web page.
Click Add Fingerprint, and press your nger on the ngerprint module of the device to add your
ngerprint.
Click Add to save the sengs.
Click Save and Congure to save the sengs and connue to add next person.
Note
The plugin for adding card or ngerprint via USB is only available in Windows.
Add PIN
Before conguring PIN, it is necessary to clarify whether the PIN is a device-set personal PIN or a
plaorm-applied personal PIN. If it is a device-set personal PIN, it can be created or edited on the
device or on the web, and cannot be set on other plaorms; If it is a plaorm-applied personal
PIN, it can be created or edited on the
plaorm, and issued to the device before it can be used. It
cannot be set on the device or on the web.
DS-K27XX Series Access Controller User Manual
48

Make sure you have already set the PIN mode as Device-Set Personal PIN in Set Password Mode .
Click PIN Mode on the page to go to congure.
Click Person Management → Add to enter the Add Person page.
Set the PIN. Or click Auto Generate to generate a PIN
automacally.
Click Add to save the sengs.
Click Save and Congure to save the sengs and connue to add next person.
Authencaon Sengs
Click Person Management → Add to enter the Add Person page.
Set the authencaon type.
Click Add to save the sengs.
Click Save and Congure to save the sengs and connue to add next person.
Permission Management
Before you start:
●
You have already add the device. For details, see
Device Management .
●
You have already complete access point management. For details, see Access Point
Management .
●
You have already complete the access permission management. For details, see Permission
Management .
Click Person Management → Add to enter the Add Person page.
Set the permission parameters.
Permission Type
By Permission Group
Click Allocate and select an added access permission. The person will contain the checked
access permission. If you have not added the access permission in advance, you can click Add
Access Permission to add. For details, see
Permission Management . Click OK.
By Access Point
Click Allocate and select the access schedule. ClickAdd to add the access points. The person
will contain the permissions of the access point within the access schedule. Click OK.
Extend Door Opening
The person related door will close aer the congured me duraon. You should go to Set Door
Parameters to set the Extended Open Duraon. Click Door Parameters to go to the
conguraon page.
Click Add to save the sengs.
Click Save and Congure to save the sengs and connue to add next person.
Edit/Delete/Search Person
Click Person Management to enter the page.
Select a person and click to edit the person's informaon.
Select a person and click to delete the person informaon.
DS-K27XX Series Access Controller User Manual
49

Select mulple person, click Delete can delete person in batch.
Click Clear All to delete all person informaon.
Click or to switch the viewing method.
Enter the person's employee ID and select the
credenal status and click Filter to search. Click
Reset to reset all
condions.
Check Show Sub Organizaon, all persons in the sub organizaons will be displayed.
9.6 Device Management
9.6.1 Search Not Added Device
The system can automacally search for not added access modules that have been connected to
the access controller.
Click Device Management → Search Not Added Device. The searched not added access modules
will be displayed in the list of the page.
Click
in the acon bar to add an access module to the access controller.
9.6.2 Add Access Module
Add access module manually.
Before You Start
Make sure that the area has been added. For more details, see Area Management .
Steps
1.
Click Device Management to enter the
sengs page.
DS-K27XX Series Access Controller User Manual
50

Figure 9-11 Add Access Module
2.
Select the dial address of the access module, and set the DIP switch of the access module to be
consistent with the one shown in the picture.
Note
Aer adding or modifying the dialing address of the access module, you need to reboot the
access module to take it eect.
3.
Set the door parameters, and click Next.
Select Door of Access Module
According to the door actually controlled by the access module, select 1 or 2.
Door Name
Create the door name associated with the access module.
Area
Choose the area from the drop-down list. If you have not created an associated area in
advance, click Add Area to create.
Open
Duraon
Set the acon me aer the associated door is unlocked. If the door is not opened within the
set
me, the door will lock automacally. The range can be set from 1 to 255 s.
Door Magnec Sensor Type
DS-K27XX Series Access Controller User Manual
51

The door magnec sensor can be controlled as Remain Closed or Remain Open. Under
normal circumstances, it is Remain Closed (except for special needs).
Exit Buon Type
Under normal circumstances, it is Remain Open (except for special needs).
Extended Open Duraon
For the elderly or children with reduced mobility, by set Extended Open Duraon, the door
magnec sensor opening me aer swiping card can be appropriately delayed.
4.
Set the card reader parameters associated with the access module.
Select Door of Access Module
According to the door actually controlled by the access module, select 1 or 2.
Select Card Reader
Select Enter or Exit according to the actual card reader
locaon.
Card Reader Name
Create the card reader name.
Card Reader Descripon
View the card reader descripon. Read Only
QR Code
If the card reader supports the QR code authencaon funcon, this funcon can be
enabled, then on the card reader, it can be carried out through the QR code authencaon.
Enable Bluetooth
If the card reader supports the Open Door via Bluetooth funcon, this funcon can be
enabled, then on the card reader, the door can be opened via bluetooth.
Authencaon Plan Conguraon
Set the authencaon plan of dierent authencaon type. You can set dierent
authencaon type in dierent me periods.
Select the
authencaon type (you can select more than one), and draw the required me
period in the me bar below, during which you can perform the selected authencaon type.
Click Clear and select the
me period that has been drawn in the me bar to clear the plan.
Click → Clear All to clear all me periods.
5.
Click OK.
6.
Oponal: Other Operaons
Icon
Descripon
You can edit the access module.
You can delete the access module.
You can restart the access module.
You can restore the access module to the factory sengs.
DS-K27XX Series Access Controller User Manual
52

You can upgrade the access module. Select a local upgrade package to upgrade.
9.6.3 Area Management
Aer you create an area, you can add access control points to the area to manage them in a
paron.
Steps
1.
Click Device Management → Area Management.
2.
Click + on the le side of the page, select a parent area, and create the area name.
3.
Click Save.
The added area will be listed in the selected parent area.
4.
Oponal: Edit / Delete
-
Select the area and click
to edit the informaon.
Select mulple personnel, and click Delete to delete the informaon of person in batch.
Click Clear All to delete informaon of all personnel.
-
Select the area, and click
to delete the informaon of area.
9.7 System and Maintenance
9.7.1 View Device Informaon
View the device name, language, model, serial No., version, number of channels, IO input, IO
output, RS-485, alarm output, and device capacity, etc.
Click System and Maintenance → System
Conguraon → System → System Sengs → Basic
Informaon to enter the conguraon page.
You can the device name, language, model, serial No., version, number of channels, IO input, IO
output, RS-485, alarm output, and device capacity, etc.
9.7.2 Set Time
Set the device's me zone, synchronizaon mode, server address, NTP port, and interval.
Click System and Maintenance → System
Conguraon → System → System Sengs → Time
Sengs .
DS-K27XX Series Access Controller User Manual
53

Figure 9-12 Time Sengs
Click Save to save the sengs aer the conguraon.
Time Zone
Select the device located me zone from the drop-down list.
Time Synchronizaon Mode
NTP
You should set the NTP server's IP address, port No., and interval.
Manual
By default, the device me should be synchronized manually. You can set the device me
manually or check Sync. with Computer Time to synchronize the device me with the
computer's me.
Server IP Address/NTP Port/Interval
You can set the server IP address, NTP port, and interval.
9.7.3 Set DST
Steps
1.
Click System and Maintenance → System
Conguraon → System → System Sengs → Time
Sengs .
2.
Enable DST.
3.
Set the DST start
me, end me and bias me.
4.
Click Save to save the sengs.
9.7.4 Change Administrator's Password
Steps
1.
Click System and Maintenance → System
Conguraon → System → User Management .
2.
Click .
DS-K27XX Series Access Controller User Manual
54

3.
Enter the old password and create a new password.
4.
Conrm the new password.
5.
Click Save.
Cauon
The password strength of the device can be automacally checked. We highly recommend you
change the password of your own choosing (using a minimum of 8 characters, including at least
three kinds of following categories: upper case leers, lower case leers, numbers, and special
characters) in order to increase the security of your product. And we recommend you change
your password regularly, especially in the high security system, changing the password monthly
or weekly can
beer protect your product.
Proper conguraon of all passwords and other security sengs is the responsibility of the
service provider and/or end-user.
9.7.5 Account Security Sengs
You can change the security quesons and answers, or the email address for the device. Aer
change the sengs, once you forgot the device password, you should answer the new quesons or
use the new email address to reset the device password.
Steps
1.
Click System and Maintenance → System
Conguraon → System → User Management →
Account Security Sengs .
2.
Change the security
quesons or email address according your actual needs.
3.
Enter the device password and click OK to conrm changing.
9.7.6 View Online User
You can view online users.
Click System and Maintenance → System Conguraon → System → User Management →
Online Users .
You can view online users'
informaon including name, type, IP Address and operaon me. Click
Refresh to refresh the page.
9.7.7 View Open Source
Soware License on PC Web
On the main page of the device PC Web, click → Open Source Soware Statement , to view the
device license.
DS-K27XX Series Access Controller User Manual
55

9.7.8 View Device Arming/Disarming Informaon
View device arming type and arming IP address.
Go to System and Maintenance → System
Conguraon → System → User Management →
Arming/Disarming Informaon .
You can view the device arming/disarming informaon. Click Refresh to refresh the page.
9.7.9 Network Sengs
Set Basic Network Parameters
Click System and Maintenance → System Conguraon → Network → Network Sengs →
TCP/IP .
Set the parameters and click Save to save the
sengs.
NIC Type
Select a NIC type from the drop-down list.
DHCP
If uncheck the funcon, you should set the IPv4 address, IPv4 subnet mask, IPv4 default
gateway, Mac address, and MTU.
If you check the
funcon, the system will allocate the IPv4 address, IPv4 subnet mask, the IPv4
default gateway
automacally.
DNS Server
Set the preferred DNS server and the Alternate DNS server according to your actual need.
Set Wi-Fi Parameters
Set the Wi-Fi parameters for device wireless connecon.
Steps
Note
The funcon should be supported by the device.
1.
Click System and Maintenance → System Conguraon → Network → Network Sengs → Wi-
Fi .
2.
Check Wi-Fi.
3.
Select a Wi-Fi
-
Click of a Wi-Fi in the list and enter the Wi-Fi password.
DS-K27XX Series Access Controller User Manual
56

-
Click Add and enter a Wi-Fi's name, password, and encrypon type. Click Connect. When the
Wi-Fi is connected, click OK.
4.
Oponal: Set the WLAN parameters.
1) Set the IP address, subnet mask, and default gateway. Or enable DHCP and the system will
allocate the IP address, subnet mask, and default gateway automacally.
5.
Click Save.
Set Port Parameters
Set the HTTP, HTTPS, HTTP Listening, RTSP and Server port parameters.
Click System and Maintenance → System Conguraon → Network → Network Service →
HTTP(S) .
HTTP
It refers to the port through which the browser accesses the device. For example, when the
HTTP Port is
modied to 81, you need to enter hp://192.0.0.65:81 in the browser for login.
HTTPS
Set the HTTPS for accessing the browser. Cercate is required when accessing.
HTTP Listening
The device can send alarm informaon to the event alarm IP address or domain name via HTTP
protocol/HTTPS protocol. Edit the event alarm IP address or domain name, URL, port, and
protocol.
Note
The event alarm IP address or domain name should support the HTTP protocol/HTTPS protocol
to receive the alarm informaon.
Click System and Maintenance → System Conguraon → Network → Network Service →
WebSocket(s) .
View WebSocket and WebSockets port.
Set ISUP Parameters
Set the ISUP parameters for accessing device via ISUP protocol.
Steps
Note
The funcon should be supported by the device.
1.
Click System and Maintenance → System Conguraon → Network → Device Access → ISUP .
DS-K27XX Series Access Controller User Manual
57

Figure 9-13 Set ISUP Parameters
2.
Check Enable.
3.
View the ISUP version, set server IP address, port, device ID,
encrypon key and view the ISUP
status.
4.
Oponal: Click More to set the network connecon priority.
1) Enable WLAN or Wired Network according to your actual needs.
1) Hold and drag
to adjust the access priority.
5.
Set the ISUP listening parameters, including ISUP alarm center IP address/domain name, ISUP
alarm center URL, and ISUP alarm center port.
6.
Click Save.
Plaorm
Access
Plaorm access provides you an opon to manage the devices via plaorm.
DS-K27XX Series Access Controller User Manual
58

Steps
1.
Click System and Maintenance → System Conguraon → Network → Device Access → Hik-
Connect to enter the sengs page.
Note
Hik-Connect is an applicaon for mobile devices. With the App, you can view live image of the
device, receive alarm nocaon and so on.
2.
Check Enable to enable the funcon.
3.
Oponal: Check Custom, and you can set the server address by yourself.
4.
Enter the vericaon code.
5.
Oponal: View the register status. Click Refresh to refresh the status.
6.
Oponal: Click More to set the network connecon priority.
1) Enable WLAN or Wired Network according to your actual needs.
1) Hold and drag
to adjust the access priority.
7.
Click View to view device QR code. Scan the QR code to bind the account.
Note
8 to 32 leers (a to z, A to Z) or numbers (0 to 9), case sensive. You are recommended to use a
combinaon of no less than 8 leers or numbers.
8.
Click Save to enable the sengs.
9.
Oponal: Click Refresh to refresh the binding status.
10.
Click Save.
9.7.10 Event
Sengs
Set the event linkage and the alarm output paramters.
Event Linkage
Set linked acons for events.
Steps
1.
Click System and Maintenance → System Conguraon → Event → Event Detecon → Linkage
Sengs to enter the page.
DS-K27XX Series Access Controller User Manual
59

Figure 9-14 Event Linkage
2.
Click
3.
Set event source.
-
If you choose Linkage Type as Event Linkage, you need to select event types from the drop-
down list.
-
If you choose Linkage Type as Card Linkage, you need to enter the card No. and select the
card reader.
-
If you choose Linkage Type as Link Employee ID, you need to enter the employee ID and
select the card reader.
4.
Set linked acon.
Linked Access Controller Buzzing
Enable Linked Access Controller Buzzing and select Start Buzzing or Stop Buzzing for the
target event.
Card Reader Linkage
Enable Card Reader Linkage and click Add can check the card reader that will buzz. Click
Save.
Set the card reader's buzzing
acon.
Click to delete single card reader. Check the card readers and click Delete to delete in
batch. Click Batch
Congure to congure all card readers in the list.
Door Linkage
Enable Door Linkage and click Add can check the card reader that will buzz. Click Save.
DS-K27XX Series Access Controller User Manual
60

Set the access point's acon.
Click to delete single card reader. Check the card readers and click Delete to delete in
batch.
Linked Alarm Output
If the Linkage Type in the Event Source is Card Linkage, when enable Linked Alarm Output,
you can set Triggering Times Conguraon, Triggering Times (Enable), and Triggering Times
(Disable).
If set Triggering Times (Enable) as 3, and Triggering Times (Disable) as 3, you can present the
card that
congured in the Event Source for 3 me to stop alarm when the following alarm
output in the list is in open status. If the alarm output is in the disabled status, you can
present the card for 3 mes to trigger alarm.
Set the alarm output. Click Add and check the alarm outputs in the list and click Save.
Click
to set the alarm duraon. Click Save.
Note
Aer the conguraon is completed, the conguraon of the same output linked to other
acons will also be changed.
Connuous Alarm
The alarm output device will connuously in the alarm status.
Custom Alarm Duraon
You should set the custom duraon. The alarm output device will be in the alarm status for
the congured me duraon.
Note
Range: from 0 to 5999s.
5.
Click Save.
Alarm
Sengs
Set the device's alarm output parameters.
Click System and Maintenance → System
Conguraon → Event → Alarm Sengs → Alarm
Output .
Select an access point from the list on the
le. Select a alarm output device No. Create a name for
the alarm output device and set the alarm duraon. Click Save.
Connuous Alarm
The alarm output device will connuously in the alarm status.
Custom Alarm Duraon
DS-K27XX Series Access Controller User Manual
61

You should set the custom duraon. The alarm output device will be in the alarm status for the
congured me duraon.
Note
Range: from 1 to 5999s.
9.7.11 Access Conguraon
You can set RS-485, Wiegand and host parameters.
Set RS-485 Parameters
You can set the RS-485 parameters including the peripheral, address, baud rate, etc.
Click System and Maintenance → System Conguraon → Access Conguraon → RS-485 .
Figure 9-15 Set RS-485 Parameters
Click Save to save the sengs aer the conguraon.
RS-485 Communicaon Backup
The controller and the access module can communicate via redundant wiring mode.
RS-485 Protocol
Select the RS-485 protocol from the drop-down list.
RS-485 Communicaon Mode
Redundant Wiring
DS-K27XX Series Access Controller User Manual
62

When the access controller connects to the terminal (RS-485A/RS-485B/RS-485C/RS-485D) of
the access module, RS-485A and RS-485B are a pair using redundancy wiring, and RS-485C
and RS-485D are another pair. When one of the channels is disconnected, the access
controller can communicate with another channel. No more than 32 access module(s) can be
connected to the access controller.
Single Wiring
RS-485A to RS-485D are communicaon terminals of the access module. The RS-485E
terminal on the access controller can be connected to RS-485A to RS-485D terminals via
single wiring for data transmission. No more than 62 access module(s) can be connected to
the access controller.
No.
Select the RS-485 No.
Baud Rate
The baud rate when the devices are
communicang via the RS-485 protocol.
Serial Port Name
View the serial port name.
Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
Note
Some device models do not support this funcon. Refer to the actual products when conguraon.
1.
Click System and Maintenance → System Conguraon → Access Conguraon → Wiegand
Sengs .
2.
Select a access point from the list on the le.
3.
Set Wiegand parameters.
No.
Select Wiegand No. for parameters sengs.
Wiegand
select to enable the card reader's Wiegand funcon.
Wiegand Direcon
By default, the direcon is Input.
Wiegand Mode
Select the Wiegand mode and the card reader can communicate with the controller by
Wiegand 26/34 or other protocol.
DS-K27XX Series Access Controller User Manual
63

Click Auto Recognize, enter card No. to recognize the Wiegand mode. Enter the Card No., and
click Start to Recognize. Present the card on the related card reader. The system will show the
Wiegand mode. Click OK.
If select Custom, you should set custom Wiegand parameters. Click Custom Wiegand
Sengs, and set the name, parity type, total length and Wiegand rule. Click OK.
Wiegand Mapping Card Reader
Select the Wiegand card reader related door and card reader
direcon.
4.
Click Save to save the sengs.
Note
If you change the peripheral, and aer you save the device parameters, the device will reboot
automacally.
Door Magnec Contact Sengs
Set the opening and closing door status of the door magnec contact to match the actual wiring
method.
Before You Start
The access controller has connected to the door magnec contact.
Steps
1.
Click System and Maintenance → Maintenance → Device Access → Host Parameter to enter
the
sengs page.
2.
Select the door magnec contact status.
Barrier Open Status (Default)
The door
magnec contact is in open status in default. Access controller is connected to the
door magnet contact through NO.
Door Closed Status
The door magnec contact is in closed status in default. Access controller is connected to the
door magnet contact through NC.
9.7.12 Card
Sengs
Set Card Security
Click System and Maintenance → System Conguraon → Card Sengs → Card Type to enter the
sengs page.
Set the parameters and click Save.
Enable NFC Card
DS-K27XX Series Access Controller User Manual
64

In order to prevent the mobile phone from geng the data of the access control, you can
enable NFC card to increase the security level of the data.
Enable M1 Card
Enable M1 card and authencang by presenng M1 card is available.
M1 Card Encrypon
Sector
M1 card
encrypon can improve the security level of authencaon.
Enable the funcon and set the encrypon sector. By default, Sector 13 is encrypted. It is
recommended to encrypt sector 13.
Enable EM Card
Enable EM card and authencang by presenng EM card is available.
Note
If the peripheral card reader supports presenng EM card, the funcon is also supported to
enable/disable the EM card funcon.
Enable DESFire Card
The device can read the data from DESFire card when enabling the DESFire card funcon.
DESFire Card Read Content
The device can read the DESFire card content.
Enable FeliCa Card
The device can read the data from FeliCa card when enabling the FeliCa card funcon.
Set Card No.
Authencaon Parameters
Set the card reading content when authencate via card on the device.
Go to System and Maintenance → System Conguraon → Card Sengs → Card No. Auth.
Sengs .
Select a card authencaon mode and set the reversed card No. and click Save.
Full Card No.
All card No. will be read.
3 bytes
The device will read card via Wiegand 26 protocol (read 3 bytes).
4 bytes
The device will read card via Wiegand 34 protocol (read 4 bytes).
Enable Reversed Card No.
The read card No. will be in reverse sequence
aer enabling the funcon.
DS-K27XX Series Access Controller User Manual
65

9.7.13 Maintenance and Security
Set Privacy Parameters
Set the event storage type, picture upload and storage parameters, and the picture clearing
parameters.
Go to System and Maintenance → System Conguraon → Security → Privacy Sengs
Select a method to delete the event. You can select from Delete Old Events Periodically, Delete
Old Events by Specied Time, or Overwring. Click Save aer conguraon.
Delete Old Events Periodically
Drag the block or enter number to set the period for event deleng. All events will be deleted
according to the
congured me duraon.
Delete Old Events by Specied Time
Set a me and all events will be deleted on the congured me.
Overwring
The earliest 5% events will be deleted when the system detects the stored events has been over
95% of the full space.
Set Password Mode
Before conguring passwords, it is necessary to clarify whether the password is a device-set
personal PIN or a plaorm-applied personal PIN. If it is a device-set personal PIN, it can be created
or edited on the device or on the web, and cannot be set on other
plaorms; If it is a plaorm-
applied personal PIN, it can be created or edited on the plaorm, and issued to the device before it
can be used. It cannot be set on the device or on the web.
Steps
1.
Click System and Maintenance → System
Conguraon → Security → PIN Mode
Device-Set Personal PIN
It can be created or edited on the device or on the web, and cannot be set on other
plaorms.
Plaorm-Applied Personal PIN
It can be created or edited on the plaorm, and issued to the device before it can be used. It
cannot be set on the device or on the web.
2.
Click Save.
DS-K27XX Series Access Controller User Manual
66

Upgrade and Maintenance
Reboot device, restore device parameters, and upgrade device version.
Reboot Device
Click System and Maintenance → Maintenance → Restart .
Click Restart to reboot the device.
Upgrade
Click System and Maintenance → Maintenance → Upgrade .
Select an upgrade type from the drop-down list. Click and select the upgrade le from your
local PC. Click Upgrade to start upgrading.
If the device has been connected to Hik-Connect and network, when there is a new
installaon
package in Hik-Connect, you can click Upgrade aer Online Update to upgrade the device system.
Note
Do not power o during the upgrading.
Sub Device Upgrade
Click System and Maintenance → Maintenance → Upgrade .
Set Upgrade
Sengs as RS-485 Card Reader, and select a card reader.
Select an upgrade type from the drop-down list. Click and select the upgrade le from your
local PC. Click Upgrade to start upgrading.
Restore Parameters
Click System and Maintenance → Maintenance → Backup and Reset .
Restore All
All parameters will be restored to the factory sengs. You should acvate the device before
usage.
Restore
The device will restore to the default
sengs, except for the device IP address and the user
informaon.
Import and Export Parameters
Click
System and Maintenance → Maintenance → Backup and Reset .
Export
Click Export to export the device parameters.
Note
You can import the exported device parameters to another device.
DS-K27XX Series Access Controller User Manual
67

Import
Click and select the le to import. Click Import to start import conguraon le.
Device Debugging
You can set device debugging parameters.
Steps
1.
Click System and Maintenance → Maintenance → Device Debugging .
2.
You can set the following parameters.
Enable SSH
To raise network security, disable SSH service. The
conguraon is only used to debug the
device for the professionals.
Print Log
You can click Export to export log.
Capture Network Packet
You can set the Capture Packet Duraon, Capture Packet Size, and click Start to capture.
Log Query
You can search and view the device logs.
Go to System and Maintenance → Maintenance → Log .
Set the major and minor type of the log type. Set the start me and end me for searching, and
click Search.
The results will be displayed below, which including the No.,
me, the major type the minor type,
the channel No., the local/remote user
informaon, the remote host IP, etc.
9.7.14
Cercate Management
It helps to manage the server/client cercates and CA cercate.
Note
The funcon is only supported by certain device models.
Create and Import HTTPS Cercate
Steps
1.
Go to Maintenance and Security → Security →
Cercate Management .
2.
In the HTTPS Cercate area, click Create Cercate Request.
DS-K27XX Series Access Controller User Manual
68

3.
Input cercate informaon and click Save.
●
Click View and the created cercate will be displayed.
●
The cercate will be saved automacally.
4.
Download the cercate and save it to an asking le in the local computer.
5.
Send the asking
le to a cercaon authority for signature.
6.
Import the signed
cercate.
1) In the Import Key area, select a cercate from the local, and click Import.
2) In the Import Communicaon Cercate area, select a cercate from the local, and click
Import.
Create and Import SYSLOG Cercate
Steps
1.
Go to Maintenance and Security → Security → Cercate Management .
2.
In the SYSLOG
Cercate area, click Create Cercate Request.
3.
Input cercate informaon and click Save.
●
Click View and the created cercate will be displayed.
●
The cercate will be saved automacally.
4.
Download the cercate and save it to an asking le in the local computer.
5.
Send the asking
le to a cercaon authority for signature.
6.
Import the signed cercate.
1) In the Import Key area, select a cercate from the local, and click Import.
2) In the Import Communicaon Cercate area, select a cercate from the local, and click
Import.
Import CA
Cercate
Before You Start
Prepare a CA
cercate in advance.
Steps
1.
Go to Maintenance and Security → Security → Cercate Management .
2.
Create an ID in the CA Cercate ID area.
Note
The input cercate ID cannot be the same as the exisng ones.
3.
Upload a cercate le from the local.
4.
Click Import.
DS-K27XX Series Access Controller User Manual
69

Chapter 10 Other Plaorms to Congure
You can also congure the device via HikCentral Access Control. For details, see the plaorms' user
manual.
HikCentral Access Control (HCAC)
Click/tap the link to view the HCAC's user manual.
hp://enpinfodata.hikvision.com/analysisQR/showQR/f2f6cf42
DS-K27XX Series Access Controller User Manual
70

Appendix A. Dimension
Dimension of 1-Door/2-Door/4-Door Access Controller
Dimension of 8-Door Access Controller
DS-K27XX Series Access Controller User Manual
71

Dimension of Access Controller Main Board
DS-K27XX Series Access Controller User Manual
72

UD35243B