Te s t S e t u p
Use this kit for safety and performance analysis of solar systems according to IEC 62446-1.
The kit contains the SMFT-1000 PV Analyzer (PV Analyzer) and the IRR2-BT Irradiance Meter
(Irradiance Meter).
The PV Analyzer provides safety and performance measurements of the solar system.
The Irradiance Meter provides auxiliary data of sun irradiance and solar panel temperature.
This data complements the IV Curve Solar Panel performance measurements on the PV
Analyzer. The IRR2-BT sends the data to the PV Analyzer wirelessly. If wireless connection is
interrupted for any reason, the Irradiance Meter automatically records the data that is later
transferred when the connection is reestablished. Both devices have synchronized clocks to
properly match the data.
Note
Before taking IV Curve performance measurements, synchronize the PV Analyzer and
Irradiance Meter via wireless connection. See Pair PV Analyzer to the Irradiance Meter.
To power on the PV Analyzer:
1. Push
for 1 s. to turn on the PV Analyzer.
The displays shows a startup screen with the firmware version.
2. Push
for 2 s. to turn off the PV Analyzer.
Pair PV Analyzer to the Irradiance Meter
For first time use, you must pair the PV Analyzer Analyzer with the Irradiance Meter:
1. Turn on the PV Analyzer and the Irradiance Meter.
2. Make sure the PV Analyzer and the Irradiance Meter are within the wireless range (<50 m) of
each other.
3. Turn the rotary dial to MENU.
4. Use
to highlight Device Settings.
5. Push
to open the Device Settings menu.
6. Use
to highlight Irradiance Meter Pairing.
7. Push
.
8. Follow the on-screen directions on the PV Analyzer to pair the devices.
shows on the PV Analyzer display to indicate that the PV Analyzer and Irradiance Meter
are connected.
After the initial setup, the PV Analyzer pairs with the IRR2-BT when you turn on both
devices and are within the wireless range (<50 m).