Professional Series Thermal Imagers
Menus
19
Color Alarm
High Alarm
Turns on/off the high-temperature color alarm. The high-
temperature color alarm shows a full visible image and only
shows infrared information on objects or areas that are above the
set apparent temperature level.
Set High Alarm
Temperature
Sets the high apparent temperature level. Requires the High
Alarm to be on.
Low Alarm
Turns on/off the low-temperature (or dew point) color alarm. The
low-temperature color alarm shows a full visible image and only
shows infrared information on objects or areas that are below the
set apparent temperature level.
Set Low Alarm
Temperature
Sets the low apparent temperature level. Requires the Low Alarm
to be on.
Note
The Imager does not sense ambient or surface dew point
level automatically. To use the low-temperature color alarm
function as a dew point color alarm, determine and input the
surface dew point temperature. The colors presented can
help identify areas of concern with possible dew point
condensation.
Outside
Shows color isotherms, or infrared information, outside of a set of
both high and low limits. Requires High Alarm and Low Alarm to
be on and temperature levels for both alarms to be set.
Inside
Shows color isotherms, or infrared information, inside of a set of
both high and low limits. Requires High Alarm and Low Alarm to
be on and temperature levels for both alarms to be set.