PARAMETER VALUE SECURITY
(get/set)
DESCRIPTION
devicemonitor_heatern
um
<integer>
0/7
Number of sensor sensors that can be
monitored.
* Only available when
"capability_peripheral_c<0~(n-1)>_devi
cemonitor_support" > 0
7.27.11 Capability for Extension Modules
Group: capability_extension
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
di_num <integer> 0/7 The number of supported extension
digital input module.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0316a.
do_num
<integer>
0/7
The number of supported extension
digital output module.
* We support this parameter when the
version number (httpversion
) is equal or
greater than 0316a.
7.27.12 Capability for Onvif
Group: capability_onvif
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
dbsize <integer> 0/7 Indicate the maximum size (Megabyte)
of persistent notification storage.
* We support this parameter when the
version number (httpversion) is equal or
greater than 0319a.
7.28 Event Setting
Group: event_i<0~(n-1)> n denotes the value of "capability_nevent"
(capability_nevent > 0)