Loading ...
Loading ...
Loading ...
WARNING Before carrying out this operation, disconnect the range from gas and electricity.
Fail to do so, may result in fire, or electrical shock hazard can occur and result in injury or death. Do not
remove regulator or allow it to turn during servicing.
The gas conversion procedure for this range includes 5 steps:
1. Pressure regulator 4. Reconnect Gas and Electrical Supply
2. Cooktop burners 5. Installation of new rating label
3. Gas valve
The conversion is not completed if all 5 steps have not been concluded properly.
Before performing the gas conversion, locate the package containing the replacement nozzles shipped with
every range.
STEP 1: Pressure Regulator
To access the gas regulator, pull the range away from the cabinet wall. The gas regulator is located
at the bottom back left corner of the range.
a. Unscrew the cap from the regulator.
b.
Unscrew the brass insert from the cap. Do not remove the spring from the brass insert. Rotate the brass
insert with the fully extended spring 180° and screw back the brass insert on the cap. Insert the cap with the
spring first into the regulator. Make sure the cap is fully tighten on the regulator, if not done correctly a gas
leak can occur.
STEP 2: Cooktop Burners
a. Remove cooking grills and burner caps.
b. Lift off outer burner spreader and burner bases.
c. Remove the factory installed natural gas nozzles from the center of the nozzle
holders using a 7mm socket wrench. Replace the LP injector in each nozzle
holder. Tighten each injector properly.
Do not to over tighten the injector.
Socket wrench
CAUTION Handle carefully when removing and replacing gas components. Use proper
support to prevent damage to components.
IMPORTANT: Each injector has a number indicating its flow diameter printed on the body. Consult the table
below for matching nozzles with cooktop burners.
ÅÅ
Å
20
Loading ...
Loading ...
Loading ...