LG Electronics LG3ZMSS316 Quad Zone Mini Split System with 30,000 BTU, Integrated Base Pan Heater, Auto

Owners Guide - Page 53

For LG3ZMSS316.

PDF File Manual, 93 pages, Read Online | Download pdf file

LG3ZMSS316 photo
Loading ...
Loading ...
Loading ...
Part 5. Trouble Shooting
- 53 -
Copyright ©2017 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Ω
10kΩ
Check the resistance
Check the voltage
V
2.5Vdc
Check Point
1. Unplug the sensor on Indoor unit PCB.
2. Estimate the resistance of each sensor.
3. If the resistance of the sensor is 10KΩ/ 5KΩ at 25°C, then sensor is normal.
4. If the resistance of the sensor is 0 KΩ or ∞, then sensor is abnormal. Change the sensor.
5. Plug the sensor on Indoor unit PCB and Power ON.
6. Estimate the voltage of each sensor.
7. If the voltage of the sensor is 2.5Vdc at 25°C, then sensor is normal.
8. If the resistance of the sensor is 0 or 5Vdc, then sensor is abnormal. Repair or Change the PCB.
6.6 Troubleshooting Indoor Error
01
02
06
Indoor air sensor
Indoor inlet pipe sensor
Indoor outlet pipe sensor
• Open / Short
• Soldered poorly
• Internal circuit error
• Open / Short
• Soldered poorly
• Internal circuit error
• Open / Short
• Soldered poorly
• Internal circuit error
Normal resistor : 10KΩ/ at 25°C (Unplugged)
Normal voltage : DC 2.5V / at 25°C (plugged)
Normal resistor : 5KΩ/ at 25°C (Unplugged)
Normal voltage : DC 2.5V / at 25°C (plugged)
Normal resistor : 5KΩ/ at 25°C (Unplugged)
Normal voltage : DC 2.5V / at 25°C (plugged)
Display
code
Title Cause of error Check point & Normal condition
Loading ...
Loading ...
Loading ...