Two-Wire Video Intercom Bundle·Quick Start Guide
7
The input voltage for electric lock is 12 V and the maximum current is 200 mA.
When use the wire in network cable as the 24AWG cable, use two wires connect to
one device and spare the other six.
Wire the three devices with power supply cables as the picture shown below.
Indoor Station
Door Station
Video/Audio
Distributor
Power Adapter
Figure 2-4 Wiring
Its suggested to connect only one video/audio distributor to one switch. If you need
to connect more than one video/audio distributor to the switch, please set the PLC
channel.
Its suggested to set the PLC channel when there are two or more sets of bundles in
use and the distance between the wires of two bundles are less than 1 m. The PLC
channel function is made to avoid crosstalk between channels.
The steps as follow:
Steps:
1. Press call button on the door station for 20 seconds to enable PLC setting mode.