Faber STSP30SSV Stilo Suprema

User Manual - Page 34

For STSP30SSV.

PDF File Manual, 124 pages, Download pdf file

Loading ...
Loading ...
Loading ...
34
CFM ADJUSTMENT < 395CFM
To start the process make sure the hood lights are On and motor is Off.
1) Press and hold T2 for 5 seconds until T1 - T2 - T3 - T4 flash for 3 seconds.
2) Press T2 until the LED's flash.
3) Press T2 again to confirm and T1 - T2 - T3 - T4 flash for 3 seconds (pressed
within 10 seconds).
4) The four LED's will flash again to confirm you have finished the CFM adjustment
to less than 395 CFM.
5) Apply the under 395 CFM label inside the hood (behind the grease filters) near
the rating label for inspection and on the front of your installation/user manual.
6) To confirm your setting for inspection, T1 and T2 and T3 buttons will always
operate the hood at speed 1 or speed 2 or speed 3. The intensive speed (T4), will
also no longer operate.
Note: The Intensive Speed will be deactivated.
Attention: When the under 395 CFM adjustment is completed, it is no longer
possible to change this setting to the original CFM level.
ATTENTION: For a correct functioning of the FABER CLOUD APP, when this
procedure is completed disconnect the plug from the power supply.and reconnect
it again.