CFM ADJUSTMENT < 295CFM
To start the process make sure the hood lights are On and motor is Off.
1) Press and hold T1 for 5 seconds until T1 - T2 - T3 - T4 flash for 3 seconds.
2) Press T1 until the LED's flash.
3) Press T1 again to confirm and T1 - T2 - T3 - T4 flash for 3 seconds (pressed
within 10 seconds).
4) The four LED's will flash again to confirm you have finished the CFM adjustment
to less than 295 CFM.
5) Apply the under 295 CFM label inside the hood (behind the grease filters) near
the rating label for inspection and on the front of your installation/user manual.
6) To confirm your setting for inspection, T1 and T2 buttons will always operate
the hood at speed 1 or speed 2. The highest speed (T3) and the intensive speed
(T4), will also no longer operate.
Note: T2 and T3 buttons will now operate at the same level and the Intensive Speed
will be deactivated.
Attention: When the under 295 CFM adjustment is completed, it is no longer
possible to change this setting to the original CFM level.
ATTENTION: For a correct functioning of the FABER CLOUD APP, when this
procedure is completed disconnect the plug from the power supply.and reconnect
it again.