3-32
The parameters emissivity and ambient temperature, as
well as path temperature, relative humidity, transmission,
and distance allow for precise temperature measurement.
To properly enter the respective correction parameters,
exact knowledge of the real properties of the measuring
object, as well as of the ambient conditions and the
measurement setup is required. The correction
parameters are accepted globally for the entire image.