NORMA 4000/5000
Operators Manual
8-8
View Efficiency
Press measuring key Σ three times (or again, if continuing from previous view).
The efficiency and the total active power are displayed.
esn036.gif
Note
The efficiency screen and totals channels 4-6 screen only appear if there
are 4 to 6 power phases equipped.
The variables for electrical efficiency measurement are user selectable. To view the
Efficiency Setup screen, press Config (F5).
esn088.gif
To view the variables, press Config (F5) again. Each of the four variables shown are
selectable from the list of active power values.