NORMA 4000/5000
Operators Manual
7-14
The configuration procedure consists of the following steps:
Call up Current Channel Setup
Configure input range
Configure scale
Configure coupling
Configure anti-aliasing filter
Call up Voltage Channel Setup
Current Channel Setup
Move the cursor to the status display of current channel I1 and press Enter.
The Current Channel Setup menu is displayed. The first field in column Auto of line I1 is
highlighted.
In the Current Channel Setup menu, define the following settings:
Column Settings Description
Ch I1 … I6 Select input (channel)
Auto Automatic range adjustment
ON activated
OFF ... deactivated
Range 30 mA ...10 A Measuring range (in ampere or volt)
30 mV ... 10 V
Scale Scale factor and A/V ratio Scale for external probes/converters
Coup AC
DC
Coupling
Filter ON Filter activated
OFF ... deactivated