![](https://files.manualsfile.com/42864544-ds-2td2117-6-pai/bg44.png)
Select to display the size informaon of the target on the alarm picture.
Snapshot Sengs
Select to upload the picture to the surveillance center when the alarm occurs. You can also
set the quality and resoluon of the picture separately.
2.
Click Save.
Go to Conguraon → Local , check Enable rules to display rules informaon on the live view.
7.3.4 Calibraon
You can calibrate the camera rst to improve the detecon accuracy of perimeter protecon. The
calibraon is oponal, take the actual condion for reference.
Note
The funcon varies according to dierent camera models.
Calibrate Automacally
Before You Start
●
Make sure that we have known the actual height of the target person in the scene.
●
Make sure there is no moving objects in the view except for the person.
Steps
1.
Go to
Conguraon → Perimeter Protecon → Camera Calibraon .
2.
Check Camera
Calibraon.
3.
When the person is totally seen in live view, enter the height of person in Target Height.
Note
You can set a maximum of two decimal places.
4.
Click to start calibraon.
Cauon
●
The auto calibraon starts when the person is totally seen in live view, and ends when the
person is in the endpoint.
●
The endpoint-to-camera distance (m) equals 4 mes the lens focal length (mm). E.g, for 7mm
lens, the recommended endpoint is 28m (7*4).
●
The person should walk in zigzag path. And two zigzag paths are required. Make sure the
walking route covers the
le, middle, right of image.
●
The auto
calibraon duraon should be no shorter than 10 sec, and no longer than 10 min.
The device will stop calibraon automacally if the duraon is too long.
●
If there is moving object such as leave or tree in the scene, you can set the shielded area .
Refer to Set Temperature Measurement Shield Region for detail sengs.