OVEN INSTALLATION INTO KITCHEN CABINET
If a power point is fitted it must be accessible with the oven installed, as the plug must be accessible after
installation.
The oven needs to be mounted onto a level flat surface for the full width and depth of the oven.
The oven must not be installed behind a decorative door or in a recess where the cooling air may be
compromised. This is an overheating risk.
The oven must be fixed in position.
The oven comes with a cable attached that needs to be terminated or plugged in according to the correct
electrical standards by an authorised electrician.
The oven is designed to be installed into standard 600mm wide cupboard that allows a flush fit with the surrounding
cupboard fronts. DO NOT install the oven recessed from the cupboard front surfaces as steam from the oven may
cause damage. Follow the measurements in the diagrams for correct installation details.
A
B
C
Style A B C
Flush fit 600 600 581min
Proud fit 565 590 560 min
16 mm
23 mm
Infill panel
Infill panel
Level the oven
Place a level as shown in the diagram to make
sure that the oven is perfectly level.
This is important as an uneven installation may
lead to leaks onto cupboard surfaces
FLUSH MOUNT PROUD MOUNT