XO UIM1565O 15 Inch Built-In Gourmet Ice Maker with Crystal Clear Cubes, 65lbs Daily

Owner Manual - Page 36

For UIM1565O.

PDF File Manual, 40 pages, Read Online | Download pdf file

UIM1565O photo
Loading ...
Loading ...
Loading ...
36
winterizing
Where seasonal installation ambient temperatures fall below 50 F
Clean and sanitize your system
Turn off the power
Empty the water container completely
Disconnect the pump hose - this requires the removal of the back panel
Close the water supply valve and disconnect the water supply line from the rear of the unit
Turn on the power and set the switch to the “WASH” position.
This will open the internal water supply valve allowing it to drain the inlet pipe
If your unit has a drain pump, pour 1/2 gallon of RV anti-freeze mixture (propylene glycol)
into the ice tank.
WARNING: Do NOT use anti-freeze intended for automobiles.
Turn the ice maker “OFF” and remove the plug from the outlet
When returning the ice maker to service - the unit must be thoroughly santized and cleaned
to ensure all chemicals and detergents are flushed from the system.
Discard the first batch of ice after returning to service.
IMPORTANT NOTE:
Should the ice maker require adjustment of the:
Evaporator temperature sensor,
Ice production cycle time delay - or -
Water supply timer
Call Customer Service, do not attempt yourself.
o
Loading ...
Loading ...
Loading ...